Ongoing Revolution in Bacteriology: Routine Identification of Bacteria by Matrix‐Assisted Laser Desorption Ionization Time‐of‐Flight Mass Spectrometry

The DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry accurately identifies both selected bacteria and bacteria in select clinical situations. It has not been evaluated for routine use in the clinic. METHODS: We prospectively analyzed routine MALDI-TOF mass spectrometry identification in parallel with conventional phenotypic identification of bacteria regardless of phylum or source of isolation. Discrepancies were resolved by 16S ribosomal RNA and rpoB gene sequence-based molecular identification. Colonies (4 spots per isolate directly deposited on the MALDI-TOF plate) were analyzed using an Autoflex II Bruker Daltonik mass spectrometer. Peptidic spectra were compared with the Bruker BioTyper database, version 2.0, and the identification score was noted. Delays and costs of identification were measured. RESULTS: Of 1660 bacterial isolates analyzed, 95.4% were correctly identified by MALDI-TOF mass spectrometry; 84.1% were identified at the species level, and 11.3% were identified at the genus level. In most cases, absence of identification (2.8% of isolates) and erroneous identification (1.7% of isolates) were due to improper database entries. Accurate MALDI-TOF mass spectrometry identification was significantly correlated with having 10 reference spectra in the database (P=.01). The mean time required for MALDI-TOF mass spectrometry identification of 1 isolate was 6 minutes for an estimated 22%-32% cost of current methods of identification. CONCLUSIONS: MALDI-TOF mass spectrometry is a cost-effective, accurate method for routine identification of bacterial isolates in <1 h using a database comprising > or =10 reference spectra per bacterial species and a 1.9 identification score (Brucker system). It may replace Gram staining and biochemical identification in the near future.

Overview

Integrity signals

Registry

Crossref · 10.1086/600885

Cites

53 of 53 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Cited by

See all 1,983

Metadata

Authors
Seng, P., Drancourt, M., Gouriet, F., La Scola, B., Fournier, P., Rolain, J. M., & Raoult, D.
Affiliations
Centre National de la Recherche Scientifique (FR)
Corresponding author
Raoult, Didier
Venue
Clinical Infectious Diseases
Published
2009-08-15
Volume
49
Issue
4
Pages
543-551
ISSN
  • 1058-4838 (ISSN-L)
  • 1537-6591
OpenAlex
W2172112723
Cited by
1,983
References
50
Citations by year
2026: 59 · 2025: 51 · 2024: 52 · 2023: 78 · 2022: 98 · 2021: 109 · 2020: 121 · 2019: 158 · 2018: 147 · 2017: 160 · 2016: 173 · 2015: 134 · 2014: 149 · 2013: 153 · 2012: 126
FWCI
72.00
Type
journal article
Language
en
Open access
closed
Locations
  • Clinical Infectious Diseases (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Microbiology (medical) › Bacterial Identification and Susceptibility Testing
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
  • Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
Keywords
MALDI-TOF mass spectrometry, bacterial identification, species identification, 16S rRNA gene sequencing, rpoB gene sequencing, identification accuracy, cost-effectiveness, biochemical identification
MeSH terms
Bacteria, Bacterial Infections, Bacterial Proteins, Bacteriological Techniques, Diagnostic Errors, Humans, Retrospective Studies, Sensitivity and Specificity, Time Factors, Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.