Effect of an Automated Sink on Handwashing Practices and Attitudes in High-Risk Units
The DOI matches its Crossref record.
Abstract
Objective: To assess the effects of an automated sink on handwashing practices and attitudes of staff. Design: Quasi-experimental crossover design. Setting: Two high-risk patient care areas, one postanesthesia recovery room (Site 1), and one neonatal intensive care unit (Site 2) in two tertiary care hospitals. Participants: All patient care staff on study units; approximately 55 individuals. Interventions: An automated sink was installed to replace one handwashing sink for about five weeks; the sink was then crossed-over for an equivalent time period to the other location. Handwashing practices of all unit staff were observed in three two-hour observation periods/week. Questionnaires were distributed to staff two weeks after sink installation and at the study's end. Results: One thousand, six hundred ten handwashes were observed. Handwashing practices differed significantly by site. For both sites, hands were washed significantly better but significantly less often with the automated sink (all p<.001). Staff expressed negative attitudes, however, about certain features of the sink, and these negative attitudes increased over the study period. Conclusions: Automated devices must be flexible enough to allow adjustments based on staff acceptance. Application of new technology to improve hand hygiene requires a multifaceted approach to behavior change. (Infect Control Hosp Epidemiol. 1991;12:422-428.)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Siegel, J. D., Rhinehart, E., Jackson, M., & Chiarello, L. (2007) · American Journal of Infection Control · doi:10.1016/j.ajic.2007.10.007 · Cited by 3,456
Guideline for hand hygiene in health-care settings
Boyce, J. M., & Pittet, D. (2002) · American Journal of Infection Control · doi:10.1067/mic.2002.130391 · Cited by 2,120
Boyce, J. M., & Pittet, D. (2002) · Infection Control & Hospital Epidemiology · doi:10.1086/503164 · Cited by 1,655
A Review of the Research Literature on Evidence-Based Healthcare Design
Ulrich, R. S., Zimring, C., Zhu, X., DuBose, J., Seo, H.-B., Choi, Y.-S., Quan, X., & Joseph, A. (2008) · HERD: Health Environments Research & Design Journal · doi:10.1177/193758670800100306 · Cited by 1,421
APIC guidelines for handwashing and hand antisepsis in health care settings
Larson, E. L. (1995) · American Journal of Infection Control · doi:10.1016/0196-6553(95)90070-5 · Cited by 771
Self-citationGoldmann, D. A. (1996) · JAMA · doi:10.1001/jama.1996.03530270074035 · Cited by 753
Interventions to improve hand hygiene compliance in patient care
Gould, D. J., Moralejo, D., Drey, N., Chudleigh, J. H., & Taljaard, M. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd005186.pub4 · Cited by 663
Improving Adherence to Hand Hygiene Practice: A Multidisciplinary Approach
Pittet, D. (2001) · Emerging Infectious Diseases · doi:10.3201/eid0702.010217 · Cited by 576
Healing environment: A review of the impact of physical environmental factors on users
Huisman, E. R. C. M., Morales, E., van Hoof, J., & Kort, H. S. M. (2012) · Building and Environment · doi:10.1016/j.buildenv.2012.06.016 · Cited by 528
Improving Compliance With Hand Hygiene in Hospitals
Pittet, D. (2000) · Infection Control & Hospital Epidemiology · doi:10.1086/501777 · Cited by 521
Alcohol-Based Handrub Improves Compliance With Hand Hygiene in Intensive Care Units
Hugonnet, S., Perneger, T. V., & Pittet, D. (2002) · Archives of Internal Medicine · doi:10.1001/archinte.162.9.1037 · Cited by 330
ANTIMICROBIAL RESISTANCE IN INTENSIVE CARE UNITS
Fridkin, S. K., & Gaynes, R. P. (1999) · Clinics in Chest Medicine · doi:10.1016/s0272-5231(05)70143-x · Cited by 325
Hand hygiene and patient care: pursuing the Semmelweis legacy
Pittet, D., & Boyce, J. M. (2001) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(09)70295-6 · Cited by 323
Naikoba, S., & Hayward, A. (2001) · Journal of Hospital Infection · doi:10.1053/jhin.2000.0882 · Cited by 298
Guidelines for intensive care unit design*
Thompson, D. R., Hamilton, D. K., Cadenhead, C. D., Swoboda, S. M., Schwindel, S. M., Anderson, D. C., Schmitz, E. V., St. Andre, A. C., Axon, D. C., Harrell, J. W., et al. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e3182413bb2 · Cited by 287
Behavioral interventions to improve infection control practices
Kretzer, E. K., & Larson, E. L. (1998) · American Journal of Infection Control · doi:10.1016/s0196-6553(98)80008-4 · Cited by 283
Self-citationCompliance with hand disinfection and its impact on hospital-acquired infections
Pittet, D. (2001) · Journal of Hospital Infection · doi:10.1016/s0195-6701(01)90012-x · Cited by 272
A systematic review of hand hygiene improvement strategies: a behavioural approach
Huis, A., van Achterberg, T., de Bruin, M., Grol, R., Schoonhoven, L., & Hulscher, M. (2012) · Implementation Science · doi:10.1186/1748-5908-7-92 · Cited by 267
“1 Knowledge, Facilities [49]”
Replace Hand Washing with Use of a Waterless Alcohol Hand Rub?
Widmer, A. F. (2000) · Clinical Infectious Diseases · doi:10.1086/313888 · Cited by 256
Effectiveness of handwashing in preventing SARS: a review
Fung, I. C., & Cairncross, S. (2006) · Tropical Medicine & International Health · doi:10.1111/j.1365-3156.2006.01734.x · Cited by 140
Metadata
- Authors
- Larson, E., McGeer, A., Quraishi, Z. A., Krenzischek, D., Parsons, B. J., Holdford, J., & Hierholzer, W. J.
- Venue
- Infection Control & Hospital Epidemiology
- Publisher
- Cambridge University Press (CUP)
- Published
- 1991-07
- Volume
- 12
- Issue
- 7
- Pages
- 422-428
- ISSN
- 0899-823X (ISSN-L)
- 1559-6834
- OpenAlex
- W2155757795
- Cited by
- 106
- References
- 0
- FWCI
- 1.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.