The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Prevention of Central Venous Catheter-Related Infections by Using Maximal Sterile Barrier Precautions During Insertion
Abstract
Objective: In many hospitals, the only sterile precautions used during the insertion of a nontunneled central venous catheter are sterile gloves and small sterile drapes. We investigated whether the use of maximal sterile barrier (consisting of mask, cap, sterile gloves, gown, and large drape) would lower the risk of acquiring catheter-related infections. Design: Prospective randomized trial. Setting: A 500-bed cancer referral center. Methods: We randomized patients to have their nontunneled central catheter inserted under maximal sterile barrier precautions or control precautions (sterile gloves and small drape only). All patients were followed for 3 months postinsertion or until the catheter was removed, whichever came first. Catheter-related infections were diagnosed by quantitative catheter cultures and/or simultaneous quantitative blood cultures. Results: The 176 patients whose catheters were inserted by using maximal sterile barrier precautions were comparable to the 167 control patients in underlying disease, degree of immuno-suppression, therapeutic interventions, and catheter risk factors for infections (duration and site of catheterization, number of catheter lumen, catheter insertion difficulty, reason for catheter removal). There were a total of four catheter infections in the test group and 12 in the control group (P=0.03, chi-square test). The catheter-related septicemia rate was 6.3 times higher in the control group (P=0.06, Fisher's exact test). Most (67%) of the catheter infections in the control group occurred during the first 2 months after insertion, whereas 25% of the catheter infections in the maximal sterile precautions group occurred during the same period (P<0.01, Fisher's exact test). Cost-benefit analysis showed the use of such precautions to be highly cost-effective. Conclusion: Maximal sterile barrier precautions during the insertion of nontunneled catheters reduce the risk of catheter infection. This practice is cost-effective and is consistent with the practice of universal precautions during an invasive procedure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Semiquantitative Culture Method for Identifying Intravenous-Catheter-Related Infection
Maki, D. G., Weise, C. E., & Sarafin, H. W. (1977) · New England Journal of Medicine · doi:10.1056/nejm197706092962301 · Cited by 2,027
Catheter Complications in Total Parenteral Nutrition
Ryan, J. A., Abel, R. M., Abbott, W. M., et al. (1974) · New England Journal of Medicine · doi:10.1056/nejm197404042901401 · Cited by 696
Infection Control in Intravenous Therapy
MAKI, D. G., GOLDMNAN, D. A., & RHAME, F. S. (1973) · Annals of Internal Medicine · doi:10.7326/0003-4819-79-6-867 · Cited by 536
Infectious Complications of Indwelling Vascular Catheters
Raad, I. I., & Bodey, G. P. (1992) · Clinical Infectious Diseases · doi:10.1093/clinids/15.2.197 · Cited by 446
Self-citationMermel, L. A., McCormick, R. D., Springman, S. R., & Maki, D. G. (1991) · The American Journal of Medicine · doi:10.1016/0002-9343(91)90369-9 · Cited by 441
Maki, D. G., Cobb, L., Garman, J. K., Shapiro, J. M., Ringer, M., & Helgerson, R. B. (1988) · The American Journal of Medicine · doi:10.1016/0002-9343(88)90579-7 · Cited by 412
Sherertz, R. J., Raad, I. I., Belani, A., Koo, L. C., Rand, K. H., Pickett, D. L., Straub, S. A., & Fauerbach, L. L. (1990) · Journal of Clinical Microbiology · doi:10.1128/jcm.28.1.76-82.1990 · Cited by 381
Self-citationLeclair, J. M., Freeman, J., Sullivan, B. F., Crowley, C. M., & Goldmann, D. A. (1987) · New England Journal of Medicine · doi:10.1056/nejm198708063170601 · Cited by 275
Kamal, G. D. (1991) · JAMA · doi:10.1001/jama.265.18.2364 · Cited by 253
Flowers, R. H. (1989) · JAMA · doi:10.1001/jama.1989.03420060094039 · Cited by 243
Kamal, G. D., Pfaller, M. A., Rempe, L. E., & Jebson, P. J. R. (1991) · JAMA · doi:10.1001/jama.1991.03460180070035 · Cited by 190
Reduction of Nosocomial Infection during Pediatric Intensive Care by Protective Isolation
Klein, B. S., Perloff, W. H., & Maki, D. G. (1989) · New England Journal of Medicine · doi:10.1056/nejm198906293202603 · Cited by 189
Vascular-Access Infections in Hospitalized Patients
Hampton, A. A., & Sherertz, R. J. (1988) · Surgical Clinics of North America · doi:10.1016/s0039-6109(16)44432-4 · Cited by 148
Tarrand, J. J., Guillot, C., Wenglar, M., Jackson, J., Lajeunesse, J. D., & Rolston, K. V. I. (1991) · Journal of Clinical Microbiology · doi:10.1128/jcm.29.10.2245-2249.1991 · Cited by 58
Lactic acidosis in malignant lymphoma
Caspar, C. B., & Oelz, O. (1991) · The American Journal of Medicine · doi:10.1016/0002-9343(91)90015-p · Cited by 47
Cited by
Guidelines for the Prevention of Intravascular Catheter-related Infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir257 · Cited by 4,699
Self-citationFreifeld, A. G., Bow, E. J., Sepkowitz, K. A., Boeckh, M. J., Ito, J. I., Mullen, C. A., Raad, I. I., Rolston, K. V., Young, J.-A. H., & Wingard, J. R. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir073 · Cited by 3,463
Self-citationKDOQI Clinical Practice Guideline for Vascular Access: 2019 Update
Lok, C. E., Huber, T. S., Lee, T., Shenoy, S., Yevzlin, A. S., Abreo, K., Allon, M., Asif, A., Astor, B. C., Glickman, M. H., et al. (2020) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2019.12.001 · Cited by 2,590
Preventing Complications of Central Venous Catheterization
McGee, D. C., & Gould, M. K. (2003) · New England Journal of Medicine · doi:10.1056/nejmra011883 · Cited by 2,290
Tomblyn, M., Chiller, T., Einsele, H., Gress, R., Sepkowitz, K., Storek, J., Wingard, J. R., Young, J.-A. H., & Boeckh, M. A. (2009) · Biology of Blood and Marrow Transplantation · doi:10.1016/j.bbmt.2009.06.019 · Cited by 1,797
Metadata
- Authors
- Raad, I. I., Hohn, D. C., Gilbreath, B. J., Suleiman, N., Hill, L. A., Bruso, P. A., Marts, K., Mansfield, P. F., & Bodey, G. P.
- Venue
- Infection Control & Hospital Epidemiology
- Publisher
- Cambridge University Press (CUP)
- Published
- 1994-04
- Volume
- 15
- Issue
- 4
- Pages
- 231-238
- ISSN
- 0899-823X (ISSN-L)
- 1559-6834
- OpenAlex
- W2013128224
- Cited by
- 774
- References
- 15
- FWCI
- 27.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.