Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 230

The DOI matches its Crossref record.

Risk of Infection Due to Central Venous Catheters: Effect of Site of Placement and Catheter Type

Goetz, Angella M., Wagener, Marilyn M., Miller, Jean M., Muder, Robert R.·1998·Infection Control & Hospital Epidemiology

Abstract

OBJECTIVE: To determine the influence of catheter site and type (single- vs triple-lumen) on infection rates associated with central venous catheterization. DESIGN: Prospective observational study of all nontunneled central venous catheters over a 28-month period. Data collected included patient characteristics, insertion site, catheter type, and receipt of parenteral nutrition. End points were clinical infection (bacteremia or site infection) and catheter contamination (clinical infection or colonization with >15 colonies on semiquantitative culture). SETTING: Medical-surgical wards of Veterans' Affairs hospital. RESULTS: Three hundred catheters were inserted into 204 patients. Seventy percent were inserted into upper-body sites, and 30% were inserted into the femoral vein. Forty-five percent were triple-lumen catheters. Bacteremia occurred in 2.7% of catheter insertions; insertion-site infections developed in 1.3%, and catheter colonization developed in 12%. Catheter contamination was associated with emergent insertion (odds ratio [OR], 6.2; 95% confidence interval [CI 95 ], 1.1-36.7; P =.04) by logistic regression and with femoral location (hazard, 4.2; CI 95 , 2.0-8.8; P =.0001) and history of transplantation (hazard, 2.8; CI 95 , 1.1-6.7; P =.024) by Cox regression. Clinical infection was not associated with any of the risk factors evaluated, although there was a trend for association with femoral location by Cox regression (hazard, 4.7; CI 95 , 0.82-26; P =.08). We did not identify an association between infection and use of triple-lumen catheters or parenteral nutrition. CONCLUSION: Our data support an association between intravenous catheter contamination and insertion at a femoral site.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1086/647742

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 230

Metadata

Authors
Goetz, A. M., Wagener, M. M., Miller, J. M., & Muder, R. R.
Venue
Infection Control & Hospital Epidemiology
Published
1998-11
Volume
19
Issue
11
Pages
842-845
ISSN
  • 0899-823X (ISSN-L)
  • 1559-6834
OpenAlex
W2086027755
Cited by
230
References
0
FWCI
11.63
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Risk of Infection Due to Central Venous Catheters: Effect of Site of Placement and Catheter Type. https://app.cochat.ai/papers/10.1086/647742
The paper
Goetz, A. M., Wagener, M. M., Miller, J. M., & Muder, R. R. (1998). Risk of Infection Due to Central Venous Catheters: Effect of Site of Placement and Catheter Type. Infection Control & Hospital Epidemiology. https://doi.org/10.1086/647742

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.