Risk of Infection Due to Central Venous Catheters: Effect of Site of Placement and Catheter Type
Abstract
OBJECTIVE: To determine the influence of catheter site and type (single- vs triple-lumen) on infection rates associated with central venous catheterization. DESIGN: Prospective observational study of all nontunneled central venous catheters over a 28-month period. Data collected included patient characteristics, insertion site, catheter type, and receipt of parenteral nutrition. End points were clinical infection (bacteremia or site infection) and catheter contamination (clinical infection or colonization with >15 colonies on semiquantitative culture). SETTING: Medical-surgical wards of Veterans' Affairs hospital. RESULTS: Three hundred catheters were inserted into 204 patients. Seventy percent were inserted into upper-body sites, and 30% were inserted into the femoral vein. Forty-five percent were triple-lumen catheters. Bacteremia occurred in 2.7% of catheter insertions; insertion-site infections developed in 1.3%, and catheter colonization developed in 12%. Catheter contamination was associated with emergent insertion (odds ratio [OR], 6.2; 95% confidence interval [CI 95 ], 1.1-36.7; P =.04) by logistic regression and with femoral location (hazard, 4.2; CI 95 , 2.0-8.8; P =.0001) and history of transplantation (hazard, 2.8; CI 95 , 1.1-6.7; P =.024) by Cox regression. Clinical infection was not associated with any of the risk factors evaluated, although there was a trend for association with femoral location by Cox regression (hazard, 4.7; CI 95 , 0.82-26; P =.08). We did not identify an association between infection and use of triple-lumen catheters or parenteral nutrition. CONCLUSION: Our data support an association between intravenous catheter contamination and insertion at a femoral site.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Guidelines for the Prevention of Intravascular Catheter-related Infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir257 · Cited by 4,699
Loveday, H. P., Wilson, J. A., Pratt, R. J., Golsorkhi, M., Tingle, A., Bak, A., Browne, J., Prieto, J., & Wilcox, M. (2014) · Journal of Hospital Infection · doi:10.1016/s0195-6701(13)60012-2 · Cited by 1,621
Guidelines for the prevention of intravascular catheter-related infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · American Journal of Infection Control · doi:10.1016/j.ajic.2011.01.003 · Cited by 1,066
Eliminating catheter-related bloodstream infections in the intensive care unit*
Berenholtz, S. M., Pronovost, P. J., Lipsett, P. A., Hobson, D., Earsing, K., Farley, J. E., Milanovich, S., Garrett-Mayer, E., Winters, B. D., Rubin, H. R., et al. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000142399.70913.2f · Cited by 988
Guidelines for the Prevention of Intravascular Catheter–Related Infections
O’Grady, N. P., Alexander, M., Dellinger, E. P., Gerberding, J. L., Heard, S. O., Maki, D. G., Masur, H., McCormick, R. D., Mermel, L. A., Pearson, M. L., et al. (2002) · Infection Control and Hospital Epidemiology · doi:10.1086/502007 · Cited by 847
Metadata
- Authors
- Goetz, A. M., Wagener, M. M., Miller, J. M., & Muder, R. R.
- Venue
- Infection Control & Hospital Epidemiology
- Publisher
- Cambridge University Press (CUP)
- Published
- 1998-11
- Volume
- 19
- Issue
- 11
- Pages
- 842-845
- ISSN
- 0899-823X (ISSN-L)
- 1559-6834
- OpenAlex
- W2086027755
- Cited by
- 230
- References
- 0
- FWCI
- 11.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Risk of Infection Due to Central Venous Catheters: Effect of Site of Placement and Catheter Type. https://app.cochat.ai/papers/10.1086/647742
- The paper
- Goetz, A. M., Wagener, M. M., Miller, J. M., & Muder, R. R. (1998). Risk of Infection Due to Central Venous Catheters: Effect of Site of Placement and Catheter Type. Infection Control & Hospital Epidemiology. https://doi.org/10.1086/647742
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.