Use of Gloves and Reduction of Risk of Injury Caused by Needles or Sharp Medical Devices in Healthcare Workers: Results from a Case-Crossover Study
The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
Objective Standard precautions are advocated for reducing the number of injuries caused by needles and sharp medical devices ("sharps injuries"), but the effectiveness of gloves in preventing such injuries has not been established. We evaluated factors associated with gloving practices and identified associations between gloving practices and sharps-injury risk. Design Usual-frequency case-crossover study. Setting Thirteen medical centers in the United States and Canada. Participants Six hundred thirty-six healthcare workers who presented to employee health clinics after sharps injury. Methods Structured telephone questionnaires were administered to assess usual behaviors and circumstances at the time of injury. Results Of 636 injured healthcare workers, 195 were scrubbed in an operating room or procedure suite when injured, and 441 were injured elsewhere. Nonscrubbed individuals were more commonly gloved when treating patients who were perceived to have a high risk of human immunodeficiency virus, hepatitis B virus, or hepatitis C virus infection than when treating other patients (adjusted odds ratio [aOR], 2.53 [95% confidence interval {CI}, 1.30-4.91]). Nurses (aOR, 0.11 [95% CI, 0.04-0.32]) and other employees (aOR, 0.24 [95% CI, 0.07-0.77]) were less commonly gloved at injury than were physicians and physician trainees. Gloves reduced injury risk in case-crossover analyses (incidence rate ratio [IRR], 0.33 [95% CI, 0.22-0.50]). In scrubbed individuals, involvement in an…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In the event of a needle-stick injury, gloves act as a barrier or protection to minimize the amount of blood that might be transmitted during the needlestick injury [39], [40].”
From Joint EFLM-COLABIOCLI Recommendation for venous blood sampling (2018) · cites this paper as [39]
In the citing paper
“There are many ways to deal with the resistance of an individual to a change [106].”
From Joint EFLM-COLABIOCLI Recommendation for venous blood sampling (2018) · cites this paper as [106]
Citations
Cites
Siegel, J. D., Rhinehart, E., Jackson, M., & Chiarello, L. (2007) · American Journal of Infection Control · doi:10.1016/j.ajic.2007.10.007 · Cited by 3,456
The Case-Crossover Design: A Method for Studying Transient Effects on the Risk of Acute Events
Maclure, M. (1991) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a115853 · Cited by 2,327 · cited 2×
“322 (51) 59(9) 143 (22) 33 (5) 79 (12) 241 (38) 370 (58) 1 (0-3) 50 (1-100) Individuals scrubbed at time of injury (n = 195)”
Guideline for Isolation Precautions in Hospitals
Garner, J. S., & the Hospital Infection Control Practices Advisory Committee (1996) · Infection Control & Hospital Epidemiology · doi:10.1017/s0195941700006123 · Cited by 994
Estimation of a Common Effect Parameter from Sparse Follow-Up Data
Greenland, S., & Robins, J. M. (1985) · Biometrics · doi:10.2307/2530643 · Cited by 794
Should We Use a Case-Crossover Design?
Maclure, M., & Mittleman, A. M. A. (2000) · Annual Review of Public Health · doi:10.1146/annurev.publhealth.21.1.193 · Cited by 746
Self-citationCONCEPTUAL PROBLEMS IN THE DEFINITION AND INTERPRETATION OF ATTRIBUTABLE FRACTIONS
GREENLAND, S., & ROBINS, J. M. (1988) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a115073 · Cited by 414
Control Sampling Strategies for Case-Crossover Studies: An Assessment of Relative Efficiency
Mittleman, M. A., Maclure, M., & Robins, J. M. (1995) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a117550 · Cited by 340 · cited 3×
“322 (51) 59(9) 143 (22) 33 (5) 79 (12) 241 (38) 370 (58) 1 (0-3) 50 (1-100) Individuals scrubbed at time of injury (n = 195)”
Self-citationPreventing Needlestick Injuries among Healthcare Workers: A WHO-ICN Collaboration
Wilburn, S. Q., & Eijkemans, G. (2004) · International Journal of Occupational and Environmental Health · doi:10.1179/oeh.2004.10.4.451 · Cited by 302
Double gloving to reduce surgical cross-infection
Tanner, J., & Parkinson, H. (2006) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003087.pub2 · Cited by 281
Guideline for isolation precautions in hospitals Part I. Evolution of isolation practices
(1996) · American Journal of Infection Control · doi:10.1016/s0196-6553(96)90050-4 · Cited by 251
Research works printed but not linked: 7
- Greenland, 2008, Modern Epidemiology
- 1997, Safer Needle Devices: Protecting Health Care Workers Administration, 1997
- 10.1001/jama.1991.03460090071035 · doi:10.1001/jama.1991.03460090071035
- 1999, NIOSH Alert: Preventing Needlestick Injuries in Health Care Settings
- 2010, Record Summary of the Request for Information on Occupational Exposure to Bloodborne Pathogens due to Percutaneous Injury: Executive Summary
- 2000, Occupational Safety: Cost and Benefit Implications of Needlestick Prevention Devices for Hospitals
- Jagger, 2010, Advances in exposure prevention: direct cost of follow-up for percutaneous and mucocutaneous exposures to at-risk body fluids: data from two hospitals
Cited by
Joint EFLM-COLABIOCLI Recommendation for venous blood sampling
Simundic, A.-M., Bölenius, K., Cadamuro, J., Church, S., Cornes, M. P., van Dongen-Lases, E. C., Eker, P., Erdeljanovic, T., Grankvist, K., Guimaraes, J. T., et al. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2018-0602 · Cited by 240
Tikka, C., Verbeek, J. H. A. M., Saarto, A., Lavoie, M., Pahwa, M., & Ijaz, S. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd009573.pub2 · Cited by 143
The prevention of infection-associated cancers
De Flora, S., & Bonanni, P. (2011) · Carcinogenesis · doi:10.1093/carcin/bgr054 · Cited by 97
Wu, S., Huang, C., Huang, S., Yang, Y., Liu, C.-W., Shulruf, B., & Chen, C.-H. (2020) · Journal of Educational Evaluation for Health Professions · doi:10.3352/jeehp.2020.17.1 · Cited by 76
“Healthcare workers who do not use personal protective equipment, such as gloves, masks, and goggles, during procedure were likely to have occupational NSI than their counterparts who wore protective gears [13].”
Okwara, E. C., Enwere, O. O., Diwe, C. K., Azike, J. E., & Chukwulebe, A. E. (2012) · Europe PMC (PubMed Central) · Cited by 40
Metadata
- Authors
- Kinlin, L. M., Mittleman, M. A., Harris, A. D., Rubin, M. A., & Fisman, D. N.
- Affiliations
- University of Toronto (CA)
- Harvard University (US)
- University of Maryland, Baltimore (US)
- University of Utah (US)
- Corresponding author
- Fisman, David N.
- Venue
- Infection Control & Hospital Epidemiology
- Publisher
- Cambridge University Press (CUP)
- Published
- 2010-09
- Volume
- 31
- Issue
- 9
- Pages
- 908-917
- ISSN
- 0899-823X (ISSN-L)
- 1559-6834
- OpenAlex
- W2079448318
- Semantic Scholar
- daacca42e5f572091bdb6bd875d583ff3d91bf1e
- Cited by
- 37
- References
- 41
- Citations by year
- 2025: 2 · 2024: 3 · 2023: 1 · 2022: 2 · 2020: 5 · 2019: 3 · 2018: 1 · 2017: 1 · 2016: 1 · 2015: 1 · 2014: 3 · 2013: 4 · 2012: 6
- FWCI
- 2.90
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Infection Control and Hospital Epidemiology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- University of Toronto
- National Institute for Occupational Safety and Health (R01-OH007489)
- Topics
- Health Sciences › Medicine › Infectious Diseases › Infection Control in Healthcare
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Occupational Health and Safety in Workplaces
- Social Sciences › Safety Research › Occupational Health and Safety Research
- Keywords
- sharps injuries, needlestick injuries, glove use, healthcare workers, occupational injury prevention, standard precautions, double gloving, risk perception, hepatitis B virus, hepatitis C virus, HIV, nurses, healthcare culture
- MeSH terms
- Academic Medical Centers, Accidents, Occupational, Adult, Attitude of Health Personnel, Canada, Female, Humans, Male, Personnel, Hospital, Surveys and Questionnaires, Risk Factors, United States, Needlestick Injuries, Gloves, Protective, Risk Assessment, Cross-Over Studies
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Use of Gloves and Reduction of Risk of Injury Caused by Needles or Sharp Medical Devices in Healthcare Workers: Results from a Case-Crossover Study. https://app.cochat.ai/papers/10.1086/655839
- The paper
- Kinlin, L. M., Mittleman, M. A., Harris, A. D., Rubin, M. A., & Fisman, D. N. (2010). Use of Gloves and Reduction of Risk of Injury Caused by Needles or Sharp Medical Devices in Healthcare Workers: Results from a Case-Crossover Study. Infection Control & Hospital Epidemiology. https://doi.org/10.1086/655839
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.