CoChat

Device-Associated Infections among Neonatal Intensive Care Unit Patients: Incidence and Associated Pathogens Reported to the National Healthcare Safety Network, 2006–2008

Open access
Hocevar, Susan N., Edwards, Jonathan R., Horan, Teresa C., Morrell, Gloria C., Iwamoto, Martha, Lessa, Fernanda C. · 2012 · Infection Control & Hospital Epidemiology
Cited by 92

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Objective.: To describe rates and pathogen distribution of device-associated infections (DAIs) in neonatal intensive care unit (NICU) patients and compare differences in infection rates by hospital type (children's vs general hospitals). Patients and Setting.: Neonates in NICUs participating in the National Healthcare Safety Network from 2006 through 2008. Methods.: We analyzed central line–associated bloodstream infections (CLABSIs), umbilical catheter–associated bloodstream infections (UCABs), and ventilator-associated pneumonia (VAP) among 304 NICUs. Differences in pooled mean incidence rates were examined using Poisson regression; nonparametric tests for comparing medians and rate distributions were used. Results.: Pooled mean incidence rates by birth weight category (750 g or less, 751–1,000 g, 1,001–1,500 g, 1,501–2,500 g, and more than 2,500 g, respectively) were 3.94, 3.09, 2.25, 1.90, and 1.60 for CLABSI; 4.52, 2.77, 1.70, 0.91, and 0.92 for UCAB; and 2.36, 2.08, 1.28, 0.86, and 0.72 for VAP. When rates of infection between hospital types were compared, only pooled mean VAP rates were significantly lower in children's hospitals than in general hospitals among neonates weighing 1,000 g or less; no significant differences in medians or rate distributions were noted. Pathogen frequencies were coagulase-negative staphylococci (28%),Staphylococcus aureus(19%), and Candida species (13%) for bloodstream infections and Pseudomonas species (16%),S. aureus(15%), and Klebsiella species (14%) for VAP. Of 673 S. aureus isolates with susceptibility results, 33% were methicillin resistant. Conclusions.: Neonates weighing 750 g or less had the highest DAI incidence. With the exception of VAP, pooled mean NICU incidence rates did not differ between children's and general hospitals. Pathogens associated with these infections can pose treatment challenges; continued efforts at prevention need to be applied to all NICU settings.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1086/668425

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 92

Metadata

Authors
Hocevar, S. N., Edwards, J. R., Horan, T. C., Morrell, G. C., Iwamoto, M., & Lessa, F. C.
Venue
Infection Control & Hospital Epidemiology
Published
2012-12
Volume
33
Issue
12
Pages
1200-1206
ISSN
  • 0899-823X (ISSN-L)
  • 1559-6834
OpenAlex
W2163075042
Cited by
92
References
3
FWCI
8.39
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Device-Associated Infections among Neonatal Intensive Care Unit Patients: Incidence and Associated Pathogens Reported to the National Healthcare Safety Network, 2006–2008. https://app.cochat.ai/papers/10.1086/668425
The paper
Hocevar, S. N., Edwards, J. R., Horan, T. C., Morrell, G. C., Iwamoto, M., & Lessa, F. C. (2012). Device-Associated Infections among Neonatal Intensive Care Unit Patients: Incidence and Associated Pathogens Reported to the National Healthcare Safety Network, 2006–2008. Infection Control & Hospital Epidemiology. https://doi.org/10.1086/668425

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.