The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
How to Calculate Molecular Column Density
Open accessAbstract
The calculation of the molecular column density from molecular spectral (rotational or ro-vibrational) transition measurements is one of the most basic quantities derived from molecular spectroscopy. Starting from first principles where we describe the basic physics behind the radiative and collisional excitation of molecules and the radiative transfer of their emission, we derive a general expression for the molecular column density. As the calculation of the molecular column density involves a knowledge of the molecular energy level degeneracies, rotational partition functions, dipole moment matrix elements, and line strengths, we include generalized derivations of these molecule-specific quantities. Given that approximations to the column density equation are often useful, we explore the optically thin, optically thick, and low-frequency limits to our derived general molecular column density relation. We also evaluate the limitations of the common assumption that the molecular excitation temperature is constant and address the distinction between beam-averaged and source-averaged column densities. As non-LTE approaches to the calculation of molecular spectral line column density have become quite common, we summarize non-LTE models that calculate molecular cloud volume densities, kinetic temperatures, and molecular column densities. We conclude our discussion of the molecular column density with worked examples for C 18 O, C 17 O, N 2 H + , NH 3 , and H 2 CO. Ancillary information on some subtleties involving line profile functions, conversion between integrated flux and brightness temperature, the calculation of the uncertainty associated with an integrated intensity measurement, the calculation of spectral line optical depth using hyperfine or isotopologue measurements, the calculation of the kinetic temperature from a symmetric molecule excitation temperature measurement, and relative hyperfine intensity calculations for NH 3 are presented in appendices. The intent of this document is to provide a reference for researchers studying astrophysical molecular spectroscopic measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SUBMILLIMETER, MILLIMETER, AND MICROWAVE SPECTRAL LINE CATALOG
PICKETT, H. M., POYNTER, R. L., COHEN, E. A., DELITSKY, M. L., PEARSON, J. C., & MÜLLER, H. S. P. (1998) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/s0022-4073(98)00091-0 · Cited by 2,157
van der Tak, F. F. S., Black, J. H., Schöier, F. L., Jansen, D. J., & van Dishoeck, E. F. (2007) · Astronomy & Astrophysics · doi:10.1051/0004-6361:20066820 · Cited by 1,689
An atomic and molecular database for analysis of submillimetre line observations
Schöier, F. L., van der Tak, F. F. S., van Dishoeck, E. F., & Black, J. H. (2005) · Astronomy & Astrophysics · doi:10.1051/0004-6361:20041729 · Cited by 1,536
Population Diagram Analysis of Molecular Line Emission
Goldsmith, P. F., & Langer, W. D. (1999) · The Astrophysical Journal · doi:10.1086/307195 · Cited by 847
Physical Conditions in Regions of Star Formation
Evans II, N. J. (1999) · Annual Review of Astronomy and Astrophysics · doi:10.1146/annurev.astro.37.1.311 · Cited by 605
Ho, P. T. P., & Townes, C. H. (1983) · Annual Review of Astronomy and Astrophysics · doi:10.1146/annurev.aa.21.090183.001323 · Cited by 527
Absolute calibration of millimeter-wavelength spectral lines.
Ulich, B. L., & Haas, R. W. (1976) · The Astrophysical Journal Supplement Series · doi:10.1086/190361 · Cited by 309
An Ammonia Spectral Atlas of Dense Cores in Perseus
Rosolowsky, E. W., Pineda, J. E., Foster, J. B., Borkin, M. A., Kauffmann, J., Caselli, P., Myers, P. C., & Goodman, A. A. (2008) · The Astrophysical Journal Supplement Series · doi:10.1086/524299 · Cited by 214
Laboratory Precision Measurements of the Rotational Spectrum of12C17O and13C17O
Klapper, G., Surin, L. A., Lewen, F., Müller, H. S. P., Pak, I., & Winnewisser, G. F. (2003) · The Astrophysical Journal · doi:10.1086/344615 · Cited by 46
Cited by
McGuire, B. A. (2022) · The Astrophysical Journal Supplement Series · doi:10.3847/1538-4365/ac2a48 · Cited by 472
Cool outflows in galaxies and their implications
Veilleux, S., Maiolino, R., Bolatto, A. D., & Aalto, S. (2020) · The Astronomy and Astrophysics Review · doi:10.1007/s00159-019-0121-9 · Cited by 466
McGuire, B. A. (2018) · The Astrophysical Journal Supplement Series · doi:10.3847/1538-4365/aae5d2 · Cited by 416
ALMA OBSERVATIONS OF CIRCUMSTELLAR DISKS IN THE UPPER SCORPIUS OB ASSOCIATION
Barenfeld, S. A., Carpenter, J. M., Ricci, L., & Isella, A. (2016) · The Astrophysical Journal · doi:10.3847/0004-637x/827/2/142 · Cited by 296
Astrochemistry and compositions of planetary systems
Öberg, K. I., & Bergin, E. A. (2021) · Physics Reports · doi:10.1016/j.physrep.2020.09.004 · Cited by 263
Metadata
- Authors
- Mangum, J. G., & Shirley, Y. L.
- Venue
- Publications of the Astronomical Society of the Pacific
- Publisher
- IOP Publishing
- Published
- 2015-03
- Volume
- 127
- Issue
- 949
- Pages
- 266-298
- ISSN
- 0004-6280 (ISSN-L)
- 1538-3873
- OpenAlex
- W2028720598
- Cited by
- 420
- References
- 9
- FWCI
- 11.96
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.