X-RAY MICROLENSING IN RXJ1131-1231 AND HE1104-1805
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
We present results from a monitoring campaign performed with the Chandra X-ray Observatory of the gravitationally lensed quasars RX J1131−1231 and HE 1104−1805. We detect significant X-ray variability in all images of both quasars. The flux variability detected in image A of RX J1131−1231 is of particular interest because of its high amplitude (a factor of ∼ 20). We interpret it as arising from microlensing since the variability is uncorrelated with that of the other images and the X-ray flux ratios show larger changes than the optical as we would expect for microlensing of the more compact X-ray emission regions. The differences between the X-ray and optical flux ratios of HE 1104−1805 are less dramatic, but there is no significant soft X-ray or dust absorption, implying the presence of X-ray microlensing in this system as well. Combining the X-ray data with the optical light curves we find that the X-ray emitting region of HE 1104−1805 is compact with a half-light radius ≲6 r g , where the gravitational radius is r g = 3.6 × 10 14 cm, thus placing significant constraints on AGN corona models. We also find that the microlensing in HE 1104−1805 favors mass models for the lens galaxy that are dominated by dark matter. Finally, we better characterize the massive foreground cluster near RX J1131−1231, set limits on other sources of extended X-ray emission, and limit the fluxes of any central odd images to be 30–50 (3σ) times fainter than the observed images.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dickey, J. M., & Lockman, F. J. (1990) · Annual Review of Astronomy and Astrophysics · doi:10.1146/annurev.aa.28.090190.001243 · Cited by 4,492
Astronomical Data Analysis Software and Systems
Argyle, R. W., Bunclark, P., & Lewis, J. R. (2008) · Cited by 4,399
Astronomical Data Analysis Software and Systems V
Jacoby, G. H., & Barnes, J. (1996) · Cited by 1,583
Reverberation mapping of the emission line regions of Seyfert galaxies and quasars
Blandford, R. D., & McKee, C. F. (1982) · The Astrophysical Journal · doi:10.1086/159843 · Cited by 1,073 · cited 1×
“Such methods include light-travel time arguments, reverberation mapping of the broad line region (Blandford & McKee 1982; Peterson 1993, Netzer & Peterson 1997), reverberation mapping of the Fe Kα emission region (Young & Reynolds 2000), occultation measurements of the central X-ray source by…”
MethodA two-phase model for the X-ray emission from Seyfert galaxies
Haardt, F., & Maraschi, L. (1991) · The Astrophysical Journal · doi:10.1086/186171 · Cited by 1,053 · cited 1×
“In the standard disk-corona model (e.g., Haardt & Maraschi 1991; Merloni 2003), it is produced in a hot, extended corona surrounding the disk.”
BackgroundReverberation mapping of active galactic nuclei
Peterson, B. M. (1993) · Publications of the Astronomical Society of the Pacific · doi:10.1086/133140 · Cited by 1,039
Advanced CCD imaging spectrometer (ACIS) instrument on the Chandra X-ray Observatory
Garmire, G. P., Bautz, M. W., Ford, P. G., Nousek, J. A., & Ricker, Jr. (2003) · SPIE Proceedings · doi:10.1117/12.461599 · Cited by 776 · cited 1×
“We monitored RX J1131−1231 and HE 1104−1805 with the Advanced CCD imaging Spectrometer (ACIS; Garmire et al. 2003) on board the Chandra X-ray Observatory (hereafter Chandra) using short (∼ 5 ksec) snapshot observations.”
MethodSelf-citationDirect Detection of Cold Dark Matter Substructure
Dalal, N., & Kochanek, C. S. (2002) · The Astrophysical Journal · doi:10.1086/340303 · Cited by 610 · cited 1×
“First, the absolute magnifications of lensed images are not well understood because substructure in the lens galaxy can modify the fluxes from the predictions of lens models (e.g., Mao & Schneider 1998; Dalal & Kochanek 2002).”
BackgroundSelf-citationEvidence for substructure in lens galaxies?
Mao, S., & Schneider, P. (1998) · Monthly Notices of the Royal Astronomical Society · doi:10.1046/j.1365-8711.1998.01319.x · Cited by 527 · cited 2×
“The differences between the X-ray flux ratios and optical flux ratios can be used to estimate the source size after accounting for absorption by the interstellar medium of the lens (e.g., Dai & Kochanek 2008) and the effects of substructures (satellites) in the lens halo (Mao & Schneider 1998).”
BackgroundMethodPeng, C. Y., Impey, C. D., Rix, H., Kochanek, C. S., Keeton, C. R., Falco, E. E., Lehar, J., & McLeod, B. A. (2006) · The Astrophysical Journal · doi:10.1086/506266 · Cited by 415 · cited 2×
“Given the estimated black hole mass of MBH = 2.4 × 10 9M⊙ (Peng et al. 2006), our fits to the X-ray and optical light curves using the microlensing model described in §2.5 indicate that the X-ray emission in HE 1104−1805 comes from a region smaller than ∼ 6rg and the UV emission region has a size…”
BackgroundMethodSelf-citation
Cited by
THE QUASAR ACCRETION DISK SIZE-BLACK HOLE MASS RELATION
Morgan, C. W., Kochanek, C. S., Morgan, N. D., & Falco, E. E. (2010) · The Astrophysical Journal · doi:10.1088/0004-637x/712/2/1129 · Cited by 367
Self-citationTWO ACCURATE TIME-DELAY DISTANCES FROM STRONG LENSING: IMPLICATIONS FOR COSMOLOGY
Suyu, S. H., Auger, M. W., Hilbert, S., Marshall, P. J., Tewes, M., Treu, T., Fassnacht, C. D., Koopmans, L. V. E., Sluse, D., Blandford, R. D., et al. (2013) · The Astrophysical Journal · doi:10.1088/0004-637x/766/2/70 · Cited by 364
Gofford, J., Reeves, J. N., Tombesi, F., Braito, V., Turner, T. J., Miller, L., & Cappi, M. (2013) · Monthly Notices of the Royal Astronomical Society · doi:10.1093/mnras/sts481 · Cited by 269
STELLAR-MASS BLACK HOLE SPIN CONSTRAINTS FROM DISK REFLECTION AND CONTINUUM MODELING
Miller, J. M., Reynolds, C. S., Fabian, A. C., Miniutti, G., & Gallo, L. C. (2009) · The Astrophysical Journal · doi:10.1088/0004-637x/697/1/900 · Cited by 253
THE SIZES OF THE X-RAY AND OPTICAL EMISSION REGIONS OF RXJ 1131-1231
Dai, X., Kochanek, C. S., Chartas, G., Kozłowski, S., Morgan, C. W., Garmire, G., & Agol, E. (2010) · The Astrophysical Journal · doi:10.1088/0004-637x/709/1/278 · Cited by 232
“Each of the Chartas et al. (2009) epochs consisted of a 5 ksec observation using ACIS-S3 in 1/8 sub-array mode from which we measure the 0.2-10 keV flux.”
BackgroundMethodInfluentialSelf-citationOguri, M., Diego, J. M., Kaiser, N., Kelly, P. L., & Broadhurst, T. (2018) · Physical Review D · doi:10.1103/physrevd.97.023518 · Cited by 227
Reverberation mapping of active galactic nuclei: From X-ray corona to dusty torus
Cackett, E. M., Bentz, M. C., & Kara, E. (2021) · iScience · doi:10.1016/j.isci.2021.102557 · Cited by 220
The masses and spins of neutron stars and stellar-mass black holes
Miller, M. C., & Miller, J. M. (2015) · Physics Reports · doi:10.1016/j.physrep.2014.09.003 · Cited by 213
“From the observational standpoint, microlensing data for quasars suggest that the X-ray source size is much smaller than that of the optical or UV [264, 213], which might imply that the emissivity index is steeper than r; this would be compatible with the steep indices required in some disk reflection fits of AGN (e.”
ResultSIZES AND TEMPERATURE PROFILES OF QUASAR ACCRETION DISKS FROM CHROMATIC MICROLENSING
Blackburne, J. A., Pooley, D., Rappaport, S., & Schechter, P. L. (2011) · The Astrophysical Journal · doi:10.1088/0004-637x/729/1/34 · Cited by 210
“The high level of X-ray microlensing variability in these two systems in particular (Chartas et al. 2009; Pooley et al. 2009) underscores the importance of making our multiwavelength observations as contemporaneous as possible (see Section 4.2 for a detailed discussion).”
BackgroundInfluentialQUASAR ACCRETION DISKS ARE STRONGLY INHOMOGENEOUS
Dexter, J., & Agol, E. (2011) · The Astrophysical Journal · doi:10.1088/2041-8205/727/1/l24 · Cited by 207
“The X-ray size has been shown by microlensing to be extremely compact (Chartas et al. 2009; Dai et al. 2010), disfavoring spectral models invoking global Comptonizing atmospheres to explain the UV emission.”
BackgroundChanging-look active galactic nuclei
Ricci, C., & Trakhtenbrot, B. (2023) · Nature Astronomy · doi:10.1038/s41550-023-02108-4 · Cited by 199
“Interestingly, the X-ray coro-nae sizes obtained through this approach are consistent with those obtained by micro-lensing studies 37 .”
ResultThe spin of supermassive black holes
Reynolds, C. S. (2013) · Classical and Quantum Gravity · doi:10.1088/0264-9381/30/24/244004 · Cited by 184
“One important point to note (in the spirit of a sanity check) is that the size/location of the x-ray source as inferred from x-ray reverberation is broadly consistent with recent estimates derived from a completely different technique, studies of microlensing in multiply lensed quasars [67, 68].”
ResultGiustini, M., & Proga, D. (2019) · Astronomy & Astrophysics · doi:10.1051/0004-6361/201833810 · Cited by 166
“By increasing MBH and ṁ, the AGN will eventually enter the BAL QSO regime, where powerful, wide-angle LD disk winds are launched (e.g., APM 08279+5255, PDS 465; see, e.g., Chartas et al. 2009c; Nardini et al. 2015).”
BackgroundInfluentialJiang 燕, Y.-F. 飞., Blaes, O., Stone, J. M., & Davis, S. W. (2019) · The Astrophysical Journal · doi:10.3847/1538-4357/ab4a00 · Cited by 162
Swift monitoring of NGC 5548: X-ray reprocessing and short-term UV/optical variability
McHardy, I. M., Cameron, D. T., Dwelly, T., Connolly, S., Lira, P., Emmanoulopoulos, D., Gelbord, J., Breedt, E., Arevalo, P., & Uttley, P. (2014) · Monthly Notices of the Royal Astronomical Society · doi:10.1093/mnras/stu1636 · Cited by 158
“…X-ray heating luminosity corrected for albedo of 6×Lx2−10, implying a low albedo of 20%, H=6Rg, consistent with Xray source sizes measured by other methods (Chartas et al. 2009, 2012; Emmanoulopoulos et al. 2014) and Rin =6Rg , the ISCO for a Schwarzchild black hole, we obtain the dashed line…”
Method
Metadata
- Authors
- Chartas, G., Kochanek, C. S., Dai, X., Poindexter, S., & Garmire, G.
- Venue
- The Astrophysical Journal
- Publisher
- American Astronomical Society
- Published
- 2009-02-27
- Volume
- 693
- Issue
- 1
- Pages
- 174-185
- ISSN
- 0004-637X (ISSN-L)
- 1538-4357
- OpenAlex
- W2068399357
- Cited by
- 180
- References
- 35
- FWCI
- 7.71
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.