Selective dielectrophoretic confinement of bioparticles in potential energy wells
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The potential energy surfaces generated by microelectrodes of polynomial and interdigitated castellated geometry have been calculated for particles experiencing both positive and negative dielectrophoretic forces. The resulting forms of particle collection at these electrodes are governed by the locations of the potential energy wells, and the theoretical predictions of the modes of collection for particles experiencing positive and negative dielectrophoretic forces are verified using mixtures of viable and non-viable yeast cells, as well as of bacteria and blood cells. An important result for the interdigitated electrodes is the finding that particles trapped in potential energy wells under the action of negative dielectrophoresis can be more easily removed from the electrode structure (e.g. by fluid flow or gravitational forces) than those trapped under positive dielectrophoresis. This was verified for mixtures of bacteria and blood cells, viable and non-viable yeast cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pethig, R., Huang, Y., Wang, X.-B., & Burt, J. P. H. (1992) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/25/5/022 · Cited by 312
Self-citationCalculation of the Electrical Capacitance of a Cube
Reitan, D. K., & Higgins, T. J. (1951) · Journal of Applied Physics · doi:10.1063/1.1699929 · Cited by 82
Precise calculation of dielectrophoretic force in arbitrary field
Washizu, M. (1993) · Journal of Electrostatics · doi:10.1016/0304-3886(93)90104-f · Cited by 63
Stoicheva, N. G., Davey, C. L., Markx, G. H., & Kell, D. B. (1989) · Biocatalysis · doi:10.3109/10242428908992034 · Cited by 58
Self-citation
Cited by
Ac electrokinetics: a review of forces in microelectrode structures
Ramos, A., Morgan, H., Green, N. G., & Castellanos, A. (1998) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/31/18/021 · Cited by 1,233
Review of cell and particle trapping in microfluidic systems
Nilsson, J., Evander, M., Hammarström, B., & Laurell, T. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.07.017 · Cited by 534
Separation of Submicron Bioparticles by Dielectrophoresis
Morgan, H., Hughes, M. P., & Green, N. G. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)76908-0 · Cited by 523
Dielectrophoretic separation of cancer cells from blood
Gascoyne, P. R. C., Wang, X.-B., Huang, Y., & Becker, F. F. (1997) · IEEE Transactions on Industry Applications · doi:10.1109/28.585856 · Cited by 406
Self-citationGupta, V., Jafferji, I., Garza, M., Melnikova, V. O., Hasegawa, D. K., Pethig, R., & Davis, D. W. (2012) · Biomicrofluidics · doi:10.1063/1.4731647 · Cited by 383
Self-citationCheng, J., Sheldon, E. L., Wu, L., Uribe, A., Gerrue, L. O., Carrino, J., Heller, M. J., & O'Connell, J. P. (1998) · Nature Biotechnology · doi:10.1038/nbt0698-541 · Cited by 347
The dielectric properties of biological cells at radiofrequencies: applications in biotechnology
Markx, G. H., & Davey, C. L. (1999) · Enzyme and Microbial Technology · doi:10.1016/s0141-0229(99)00008-3 · Cited by 333
Self-citationDielectrophoresis-Based Sample Handling in General-Purpose Programmable Diagnostic Instruments
Gascoyne, P. R. C., & Vykoukal, J. V. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820535 · Cited by 321
Yang, J., Huang, Y., Wang, X.-B., Becker, F. F., & Gascoyne, P. R. C. (1999) · Analytical Chemistry · doi:10.1021/ac981250p · Cited by 310
Self-citationDielectrophoretic Assembly of Metallodielectric Janus Particles in AC Electric Fields
Gangwal, S., Cayre, O. J., & Velev, O. D. (2008) · Langmuir · doi:10.1021/la8015222 · Cited by 298
Dielectrophoresis: Using Inhomogeneous AC Electrical Fields to Separate and Manipulate Cells
Pethig, R. (1996) · Critical Reviews in Biotechnology · doi:10.3109/07388559609147425 · Cited by 286
Self-citationDetection of pathogens in foods: the current state-of-the-art and future directions
Dwivedi, H. P., & Jaykus, L.-A. (2011) · Critical Reviews in Microbiology · doi:10.3109/1040841x.2010.506430 · Cited by 255
Dielectrophoresis of Submicrometer Latex Spheres. 1. Experimental Results
Green, N. G., & Morgan, H. (1999) · The Journal of Physical Chemistry B · doi:10.1021/jp9829849 · Cited by 239
Dielectrophoretic manipulation of rod-shaped viral particles
Morgan, H., & Green, N. G. (1997) · Journal of Electrostatics · doi:10.1016/s0304-3886(97)00159-9 · Cited by 232
Morgan, H., Izquierdo, A. G., Bakewell, D., Green, N. G., & Ramos, A. (2001) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/34/10/316 · Cited by 209
Selective detection of viable bacteria using dielectrophoretic impedance measurement method
Suehiro, J., Hamada, R., Noutomi, D., Shutou, M., & Hara, M. (2003) · Journal of Electrostatics · doi:10.1016/s0304-3886(02)00124-9 · Cited by 206
Rare cell capture in microfluidic devices
Pratt, E. D., Huang, C., Hawkins, B. G., Gleghorn, J. P., & Kirby, B. J. (2011) · Chemical Engineering Science · doi:10.1016/j.ces.2010.09.012 · Cited by 194
“lysodeikticus from erythrocytes based on their differing dielectric properties (Wang et al., 1993).”
BackgroundDielectrophoretic separation of bacteria using a conductivity gradient
Markx, G. H., Dyda, P. A., & Pethig, R. (1996) · Journal of Biotechnology · doi:10.1016/0168-1656(96)01617-3 · Cited by 191
Self-citationGreen, N. G., Ramos, A., & Morgan, H. (2002) · Journal of Electrostatics · doi:10.1016/s0304-3886(02)00069-4 · Cited by 181
Manipulation and trapping of sub-micron bioparticles using dielectrophoresis
Green, N. G., Morgan, H., & Milner, J. J. (1997) · Journal of Biochemical and Biophysical Methods · doi:10.1016/s0165-022x(97)00033-x · Cited by 181
“For example, the DEP force necessary to move a cell or micro-organism is of the order of a 5 21 few pN [12] which can be generated with an electric field of 1 3 10 V m (equivalent to 10 V across an electrode gap of 0.”
BackgroundSeparation of Polystyrene Microbeads Using Dielectrophoretic/Gravitational Field-Flow-Fractionation
Wang, X.-B., Vykoukal, J., Becker, F. F., & Gascoyne, P. R. C. (1998) · Biophysical Journal · doi:10.1016/s0006-3495(98)77975-5 · Cited by 175
Self-citationParticle-localized AC and DC manipulation and electrokinetics
Velev, O. D., Gangwal, S., & Petsev, D. N. (2009) · Annual Reports Section "C" (Physical Chemistry) · doi:10.1039/b803015b · Cited by 158
The use of electric fields in tissue engineering: A review
Markx, G. H. (2008) · Organogenesis · doi:10.4161/org.5799 · Cited by 92
Metadata
- Authors
- Wang, X. B., Huang, Y., Burt, J. P. H., Markx, G. H., & Pethig, R.
- Venue
- Journal of Physics D: Applied Physics
- Publisher
- IOP Publishing
- Published
- 1993-08-14
- Volume
- 26
- Issue
- 8
- Pages
- 1278-1285
- ISSN
- 0022-3727 (ISSN-L)
- 1361-6463
- OpenAlex
- W2006044860
- Cited by
- 223
- References
- 4
- FWCI
- 10.52
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.