The DOI matches its Crossref record.
Vibrational imaging and microspectroscopies based on coherent anti-Stokes Raman scattering microscopy
Abstract
For noninvasive characterization of chemical species or biological components within a complex heterogeneous system, their intrinsic molecular vibrational properties can be used in contrast mechanisms in optical microscopy. A series of recent advances have made coherent anti-Stokes Raman scattering (CARS) microscopy a powerful technique that allows vibrational imaging with high sensitivity, high spectral resolution and three-dimensional sectioning capability. In this review, we discuss theoretical and experimental aspects of CARS microscopy in a collinear excitation beam geometry. Particular attention is given to the underlying physical principles behind the new features of CARS signal generation under tight focusing conditions. We provide a brief overview of the instrumentation of CARS microscopy and its experimental characterization by means of imaging of model systems and live unstained cells. CARS microscopy offers the possibility of spatially resolved vibrational spectroscopy, providing chemical and physical structure information of molecular specimens on the sub-micrometre length scale. We review multiplex CARS microspectroscopy allowing fast acquisition of frequency-resolved CARS spectra, time-resolved CARS microspectroscopy recording ultrafast Raman free induction decays and CARS correlation spectroscopy probing dynamical processes with chemical selectivity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lipidomics: New Tools and Applications
Wenk, M. R. (2010) · Cell · doi:10.1016/j.cell.2010.11.033 · Cited by 589
Probing Liquid/Solid Interfaces at the Molecular Level
Zaera, F. (2012) · Chemical Reviews · doi:10.1021/cr2002068 · Cited by 458
Vibrational imaging based on stimulated Raman scattering microscopy
Nandakumar, P., Kovalev, A., & Volkmer, A. (2009) · New Journal of Physics · doi:10.1088/1367-2630/11/3/033026 · Cited by 401
Self-citationStimulated Raman Scattering: From Bulk to Nano
Prince, R. C., Frontiera, R. R., & Potma, E. O. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00545 · Cited by 350
Hyperspectral Imaging with Stimulated Raman Scattering by Chirped Femtosecond Lasers
Fu, D., Holtom, G., Freudiger, C., Zhang, X., & Xie, X. S. (2013) · The Journal of Physical Chemistry B · doi:10.1021/jp308938t · Cited by 322
Metadata
- Authors
- Volkmer, A.
- Venue
- Journal of Physics D: Applied Physics
- Publisher
- IOP Publishing
- Published
- 2005-02-19
- Volume
- 38
- Issue
- 5
- Pages
- R59-R81
- ISSN
- 0022-3727 (ISSN-L)
- 1361-6463
- OpenAlex
- W2038703722
- Cited by
- 244
- References
- 0
- FWCI
- 9.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Vibrational imaging and microspectroscopies based on coherent anti-Stokes Raman scattering microscopy. https://app.cochat.ai/papers/10.1088/0022-3727/38/5/r01
- The paper
- Volkmer, A. (2005). Vibrational imaging and microspectroscopies based on coherent anti-Stokes Raman scattering microscopy. Journal of Physics D: Applied Physics. https://doi.org/10.1088/0022-3727/38/5/r01
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.