Terahertz Fourier transform characterization of biological materials in a liquid phase
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Significant progress has been achieved during the last several years relating to experimental and theoretical aspects of terahertz (or submillimetre wave) Fourier transform spectroscopy of biological macromolecules. However, previous research in this spectral range has been focused on bio-materials in solid state since it was common opinion that high water absorption will obscure the spectral signatures of the bio-molecules in solutions. At the same time, the biological functions of DNA and proteins take place in water solutions. In this work, the spectra of DNA samples have been measured in liquid phase (gel) over the spectral range 10–25 cm −1 and compared with spectra obtained from solid films. The results demonstrate that there is very little interference between the spectral features of the material under test and the water background except for the band around 18.6 cm −1 . Multiple resonances due to low frequency vibrational modes within biological macromolecules in solutions are unambiguously demonstrated. Higher level of sensitivity and higher sharpness of vibrational modes are observed in the liquid environment in comparison with the solid phase, with the width of spectral lines 0.3–0.5 cm −1 . Gel sample spectra are found to be polarization-dependent. The ability of THz spectroscopy to characterize samples in liquid phase could be very important since it permits examination of DNA interactions in real (wet) samples. One demonstrated example of practical importance is the ability to discriminate between spectral patterns for native and denaturated DNA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Integrated THz technology for label-free genetic diagnostics
Nagel, M., Haring Bolivar, P., Brucherseifer, M., Kurz, H., Bosserhoff, A., & Büttner, R. (2002) · Applied Physics Letters · doi:10.1063/1.1428619 · Cited by 543
Cited by
Biomedical Applications of Terahertz Spectroscopy and Imaging
Yang, X., Zhao, X., Yang, K., Liu, Y., Liu, Y., Fu, W., & Luo, Y. (2016) · Trends in Biotechnology · doi:10.1016/j.tibtech.2016.04.008 · Cited by 968
Applications of Terahertz Spectroscopy in Biosystems
Plusquellic, D. F., Siegrist, K., Heilweil, E. J., & Esenturk, O. (2007) · ChemPhysChem · doi:10.1002/cphc.200700332 · Cited by 310
On the strong and narrow absorption signature in lactose at 0.53THz
Brown, E. R., Bjarnason, J. E., Fedor, A. M., & Korter, T. M. (2007) · Applied Physics Letters · doi:10.1063/1.2437107 · Cited by 124
High-Resolution Terahertz Spectrometer
Klatt, G., Gebs, R., Schäfer, H., Nagel, M., Janke, C., Bartels, A., & Dekorsy, T. (2011) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2010.2047635 · Cited by 53
“Compared to classic free-space radiation analysis [38], [39], this field localization”
Nakagawa, M., Kanda, N., Otsu, T., Ito, I., Kobayashi, Y., & Matsunaga, R. (2023) · Optics Express · doi:10.1364/oe.488866 · Cited by 3
Metadata
- Authors
- Globus, T., Woolard, D., Crowe, T. W., Khromova, T., Gelmont, B., & Hesler, J.
- Venue
- Journal of Physics D: Applied Physics
- Publisher
- IOP Publishing
- Published
- 2006-07-21
- Volume
- 39
- Issue
- 15
- Pages
- 3405-3413
- ISSN
- 0022-3727 (ISSN-L)
- 1361-6463
- OpenAlex
- W2033008552
- Cited by
- 89
- References
- 1
- FWCI
- 9.45
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Terahertz Fourier transform characterization of biological materials in a liquid phase. https://app.cochat.ai/papers/10.1088/0022-3727/39/15/028
- The paper
- Globus, T., Woolard, D., Crowe, T. W., Khromova, T., Gelmont, B., & Hesler, J. (2006). Terahertz Fourier transform characterization of biological materials in a liquid phase. Journal of Physics D: Applied Physics. https://doi.org/10.1088/0022-3727/39/15/028
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.