Cited by 53Terahertz technology and applicationsSpectroscopy and Laser ApplicationsLaser-Matter Interactions and Applications

High-Resolution Terahertz Spectrometer

Klatt, Gregor, Gebs, Raphael, Schäfer, Hanjo, Nagel, Michael, Janke, Christof, Bartels, Albrecht, Dekorsy, Thomas·2011·IEEE Journal of Selected Topics in Quantum Electronics

Abstract

Terahertz time-domain spectroscopy (THz-TDS) based on high-speed asynchronous optical sampling (ASOPS) with two offset-locked GHz femtosecond lasers requires no mechanical time-delay scanner. Consequently, measurements with 1-GHz frequency resolution are performed at intrinsically high scan rates in the multikilohertz range. This is at least one order, in most cases several orders of magnitude faster than conventional approaches employing mechanical time-delay scanners. We report a system offering a unique combination of high-frequency resolution (1 GHz) and high scan rate (2 kHz) with a spectral coverage of more than 6 THz. Its capabilities for high-precision spectroscopy are demonstrated by measuring the absorption spectrum of a mixture of H2O, D2O, and hydrogen deuterium oxide (HDO) vapor. H2O and HDO vapor absorption spectra are accurately tabulated in databases. However, D2O absorption data are rare, because of residual H2O and HDO often present when measuring pure D2O. Here, we present a high-resolution absorption spectrum of D2O vapor numerically extracted from the absorption spectrum of the three-component mixture. In addition, we show that the high spectral resolution of the ASOPS THz-TDS system provides benefits in the analysis of frequency-selective surface sensors, which are promising candidates for biosensing applications in the THz regime.

Integrity signals

Registry

Crossref · 10.1109/jstqe.2010.2047635

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Klatt, G., Gebs, R., Schäfer, H., Nagel, M., Janke, C., Bartels, A., & Dekorsy, T.
Affiliations
  • University of Konstanz (DE)
  • RWTH Aachen University (DE)
Venue
IEEE Journal of Selected Topics in Quantum Electronics
Published
2011-01
Volume
17
Issue
1
Pages
159-168
ISSN
  • 1077-260X (ISSN-L)
  • 1558-4542
OpenAlex
W2001214649
Cited by
53
References
2
Citations by year
2026: 1 · 2025: 6 · 2024: 4 · 2023: 5 · 2022: 4 · 2021: 3 · 2020: 1 · 2019: 5 · 2018: 2 · 2017: 2 · 2016: 5 · 2015: 2 · 2014: 2 · 2013: 6 · 2012: 2
FWCI
2.77
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Journal of Selected Topics in Quantum Electronics (publishedVersion)
  • KOPS (University of Konstanz) (submittedVersion)
  • RWTH Publications (RWTH Aachen) (submittedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Terahertz technology and applications
  • Physical Sciences › Chemistry › Spectroscopy › Spectroscopy and Laser Applications
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Laser-Matter Interactions and Applications
Keywords
terahertz time-domain spectroscopy, asynchronous optical sampling, high frequency resolution, biosensing, terahertz spectroscopy

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review