Single-sided device for magnetic particle imaging
The DOI matches its Crossref record.
Abstract
Recently, a new imaging modality called magnetic particle imaging (MPI) was introduced. The method is capable of imaging the distribution of superparamagnetic nanoparticles at high sensitivity, high resolution and high imaging speed by exploiting their non-linear magnetization curve. Up to now, all published simulation as well as experimental work uses a scanner setup, where the field of view (FOV) lies in between a symmetric coil configuration. This, however, poses a size limitation for the specimens. In this paper, we present a feasibility study of a new, so-called single-sided scanner, which is applied to the object of interest merely from one side. Thus, the problem of the specimen fitting into the scanner no longer exists, which denotes a major step for MPI. To date, the FOV of the single-sided device is limited to one dimension. First experimental results on imaging phantoms containing a superparamagnetic fluid show a resolution of up to 1 mm and are indeed promising.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Progress in applications of magnetic nanoparticles in biomedicine
Pankhurst, Q. A., Thanh, N. T. K., Jones, S. K., & Dobson, J. (2009) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/42/22/224001 · Cited by 1,455
Goodwill, P. W., & Conolly, S. M. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2052284 · Cited by 395
Human-sized magnetic particle imaging for brain applications
Graeser, M., Thieben, F., Szwargulski, P., Werner, F., Gdaniec, N., Boberg, M., Griese, F., Möddel, M., Ludewig, P., van de Ven, D., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-09704-x · Cited by 334
Self-citationMultidimensional X-Space Magnetic Particle Imaging
Goodwill, P. W., & Conolly, S. M. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2125982 · Cited by 319
Magnetic particle imaging: current developments and future directions
Panagiotopoulos, N., Vogt, F., Barkhausen, J., Buzug, T. M., Duschka, R. L., Lüdtke-Buzug, K., Ahlborg, M., Bringout, G., Debbeler, C., Gräser, M., et al. (2015) · International Journal of Nanomedicine · doi:10.2147/ijn.s70488 · Cited by 289
Self-citation
Metadata
- Authors
- Sattel, T. F., Knopp, T., Biederer, S., Gleich, B., Weizenecker, J., Borgert, J., & Buzug, T. M.
- Venue
- Journal of Physics D: Applied Physics
- Publisher
- IOP Publishing
- Published
- 2008-12-18
- Volume
- 42
- Issue
- 2
- Pages
- 022001
- ISSN
- 0022-3727 (ISSN-L)
- 1361-6463
- OpenAlex
- W2090159769
- Cited by
- 151
- References
- 0
- FWCI
- 5.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Single-sided device for magnetic particle imaging. https://app.cochat.ai/papers/10.1088/0022-3727/42/2/022001
- The paper
- Sattel, T. F., Knopp, T., Biederer, S., Gleich, B., Weizenecker, J., Borgert, J., & Buzug, T. M. (2009). Single-sided device for magnetic particle imaging. Journal of Physics D: Applied Physics. https://doi.org/10.1088/0022-3727/42/2/022001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.