Ozone correlates with antibacterial effects from indirect air dielectric barrier discharge treatment of water
The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
Ambient-condition air plasma produced by indirect dielectric barrier discharges can rapidly disinfect aqueous solutions contaminated with bacteria and other microorganisms. In this study, we measured key chemical species in plasma-treated aqueous solutions and the associated antimicrobial effect for varying discharge power densities, exposure times, and buffer components in the aqueous medium. The aqueous chemistry corresponded to air plasma chemistry, and we observed a transition in composition from ozone mode to nitrogen oxides mode as the discharge power density increased. The inactivation of E. coli correlates well with the aqueous-phase ozone concentration, suggesting that ozone is the dominant species for bacterial inactivation under these conditions. Published values of ozone-water antibacterial inactivation kinetics as a function of the product of ozone concentration and contact time are consistent with our results. In contrast to earlier studies of plasma-treated water disinfection, ozone-dependent bacterial inactivation does not require acidification of the aqueous medium and the bacterial inactivation rates are far higher. Furthermore, we show that the antimicrobial effect depends strongly on gas-liquid mixing following plasma treatment, apparently because of the low solubility of ozone and the slow rate of mass transfer from the gas phase to the liquid. Without thorough mixing of the ozone-containing gas and bacteria-laden water, the antimicrobial effect will not be observed. However, it should be recognized that the complexity of atmospheric pressure plasma devices, and their sensitivity to subtle differences in design and operation, can lead to different results with different mechanisms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nitric oxide: physiology, pathophysiology, and pharmacology.
Moncada, S., Palmer, R. M., & Higgs, E. A. (1991) · Pharmacological Reviews · doi:10.1016/s0031-6997(25)06663-3 · Cited by 15,525
The nitrate-nitrite-nitric oxide pathway in physiology and therapeutics
Lundberg, J. O., Weitzberg, E., & Gladwin, M. T. (2008) · Nature Reviews Drug Discovery · doi:10.1038/nrd2466 · Cited by 2,739
Determination of ozone in water by the indigo method
Bader, H., & Hoigné, J. (1981) · Water Research · doi:10.1016/0043-1354(81)90054-3 · Cited by 2,189
Rate constants of reactions of ozone with organic and inorganic compounds in water—I
Hoigné, J., & Bader, H. (1983) · Water Research · doi:10.1016/0043-1354(83)90098-2 · Cited by 1,830
Low-pressure solubility of gases in liquid water
Wilhelm, E., Battino, R., & Wilcock, R. J. (1977) · Chemical Reviews · doi:10.1021/cr60306a003 · Cited by 1,807
Graves, D. B. (2012) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/45/26/263001 · Cited by 1,518
Self-citationLow Temperature Plasma‐Based Sterilization: Overview and State‐of‐the‐Art
Laroussi, M. (2005) · Plasma Processes and Polymers · doi:10.1002/ppap.200400078 · Cited by 1,111
The Role of Acidification for Antimicrobial Activity of Atmospheric Pressure Plasma in Liquids
Oehmigen, K., Hähnel, M., Brandenburg, R., Wilke, C., Weltmann, K. ‐., & von Woedtke, T. (2010) · Plasma Processes and Polymers · doi:10.1002/ppap.200900077 · Cited by 726
Low temperature atmospheric pressure plasma sources for microbial decontamination
Ehlbeck, J., Schnabel, U., Polak, M., Winter, J., von Woedtke, T., Brandenburg, R., von dem Hagen, T., & Weltmann, K.-D. (2011) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/44/1/013002 · Cited by 723
Sakiyama, Y., Graves, D. B., Chang, H.-W., Shimizu, T., & Morfill, G. E. (2012) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/45/42/425201 · Cited by 584
Self-citation
Cited by
Plasma–liquid interactions: a review and roadmap
Bruggeman, P. J., Kushner, M. J., Locke, B. R., Gardeniers, J. G. E., Graham, W. G., Graves, D. B., Hofman-Caris, R. C. H. M., Maric, D., Reid, J. P., Ceriani, E., et al. (2016) · Plasma Sources Science and Technology · doi:10.1088/0963-0252/25/5/053002 · Cited by 1,725
Self-citationLukes, P., Dolezalova, E., Sisrova, I., & Clupek, M. (2014) · Plasma Sources Science and Technology · doi:10.1088/0963-0252/23/1/015019 · Cited by 1,181
Plasma-activated water: generation, origin of reactive species and biological applications
Zhou, R., Zhou, R., Wang, P., Xian, Y., Mai-Prochnow, A., Lu, X., Cullen, P. J., Ostrikov, K. (., & Bazaka, K. (2020) · Journal of Physics D: Applied Physics · doi:10.1088/1361-6463/ab81cf · Cited by 714
Reuter, S., von Woedtke, T., & Weltmann, K.-D. (2018) · Journal of Physics D: Applied Physics · doi:10.1088/1361-6463/aab3ad · Cited by 522
Shen, J., Tian, Y., Li, Y., Ma, R., Zhang, Q., Zhang, J., & Fang, J. (2016) · Scientific Reports · doi:10.1038/srep28505 · Cited by 410
Atmospheric pressure dielectric barrier discharges interacting with liquid covered tissue
Tian, W., & Kushner, M. J. (2014) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/47/16/165201 · Cited by 367
Bradu, C., Kutasi, K., Magureanu, M., Puač, N., & Živković, S. (2020) · Journal of Physics D: Applied Physics · doi:10.1088/1361-6463/ab795a · Cited by 318
Wende, K., Williams, P., Dalluge, J., Van Gaens, W., Aboubakr, H., Bischof, J., von Woedtke, T., Goyal, S. M., Weltmann, K.-D., Bogaerts, A., et al. (2015) · Biointerphases · doi:10.1116/1.4919710 · Cited by 279
Liu, D. X., Liu, Z. C., Chen, C., Yang, A. J., Li, D., Rong, M. Z., Chen, H. L., & Kong, M. G. (2016) · Scientific Reports · doi:10.1038/srep23737 · Cited by 269
Tian, Y., Ma, R., Zhang, Q., Feng, H., Liang, Y., Zhang, J., & Fang, J. (2015) · Plasma Processes and Polymers · doi:10.1002/ppap.201400082 · Cited by 263
Physicochemical processes in the indirect interaction between surface air plasma and deionized water
Liu, Z. C., Liu, D. X., Chen, C., Li, D., Yang, A. J., Rong, M. Z., Chen, H. L., & Kong, M. G. (2015) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/48/49/495201 · Cited by 260
Applications of Plasma-Liquid Systems: A Review
Rezaei, F., Vanraes, P., Nikiforov, A., Morent, R., & De Geyter, N. (2019) · Materials · doi:10.3390/ma12172751 · Cited by 228
“[193] concluded that the antimicrobial rates with ozone were much faster than previously reported antimicrobial rates for inactivation affected by nitrogen oxides and low pH values.”
BackgroundResultWinter, J., Tresp, H., Hammer, M. U., Iseni, S., Kupsch, S., Schmidt-Bleker, A., Wende, K., Dünnbier, M., Masur, K., Weltmann, K.-D., et al. (2014) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/47/28/285401 · Cited by 227
“the inactivation efficacy of Escherichia coli [10, 11].”
Jablonowski, H., & von Woedtke, T. (2015) · Clinical Plasma Medicine · doi:10.1016/j.cpme.2015.11.003 · Cited by 208
Kondeti, V. S. S. K., Phan, C. Q., Wende, K., Jablonowski, H., Gangal, U., Granick, J. L., Hunter, R. C., & Bruggeman, P. J. (2018) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2018.05.083 · Cited by 197
Aboubakr, H. A., Gangal, U., Youssef, M. M., Goyal, S. M., & Bruggeman, P. J. (2016) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/49/20/204001 · Cited by 187
Reducing energy cost of NO production in air plasmas
Pei, X., Gidon, D., Yang, Y.-J., Xiong, Z., & Graves, D. B. (2019) · Chemical Engineering Journal · doi:10.1016/j.cej.2019.01.011 · Cited by 178
Self-citationLaurita, R., Barbieri, D., Gherardi, M., Colombo, V., & Lukes, P. (2015) · Clinical Plasma Medicine · doi:10.1016/j.cpme.2015.10.001 · Cited by 163
Bauer, A., Ni, Y., Bauer, S., Paulsen, P., Modic, M., Walsh, J. L., & Smulders, F. J. M. (2017) · Meat Science · doi:10.1016/j.meatsci.2017.02.003 · Cited by 94
Metadata
- Authors
- Pavlovich, M. J., Chang, H.-W., Sakiyama, Y., Clark, D. S., & Graves, D. B.
- Venue
- Journal of Physics D: Applied Physics
- Publisher
- IOP Publishing
- Published
- 2013-03-07
- Volume
- 46
- Issue
- 14
- Pages
- 145202
- ISSN
- 0022-3727 (ISSN-L)
- 1361-6463
- OpenAlex
- W2082684897
- Cited by
- 259
- References
- 46
- FWCI
- 18.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.