Geodetic techniques for time and frequency comparisons using GPS phase and code measurements
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
We review the development and status of GPS geodetic methods for high-precision global time and frequency comparisons. A comprehensive view is taken, including hardware effects in the transmitting satellites and tracking receiver stations, data analysis and interpretation, and comparisons with independent results. Other GPS techniques rely on single-frequency data and/or assume cancellation of most systematic errors using differences between simultaneous observations. By applying the full observation modelling of modern geodesy to dual-frequency observations of GPS carrier phase and pseudorange, the precision of timing comparisons can be improved from the level of several nanoseconds to near 100 ps. For an averaging interval of one day, we infer a limiting Allan deviation of about 1.4 × 10 −15 for the GPS geodetic technique. The accuracy of time comparisons is set by the ability to calibrate the absolute instrumental delays through the GPS receiver and antenna chain, currently about 3 ns. Geodetic clock measurements are available for most of the major timing laboratories, as well as for many other tracking stations and the satellites, via the routine products of the International GPS Service.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Precise point positioning for the efficient and robust analysis of GPS data from large networks
Zumberge, J. F., Heflin, M. B., Jefferson, D. C., Watkins, M. M., & Webb, F. H. (1997) · Journal of Geophysical Research: Solid Earth · doi:10.1029/96jb03860 · Cited by 3,620 · cited 3×
“Rather than form large global network GPS solutions, for most applications it is much more economical and efficient to analyse data from individual stations in the PPP mode [ 3 ].”
BackgroundMethodInfluentialPrecise Point Positioning Using IGS Orbit and Clock Products
Kouba, J., & Héroux, P. (2001) · GPS Solutions · doi:10.1007/pl00012883 · Cited by 1,488 · cited 1×
“(In some variations of the PPP method, partial relaxation of the orbits and clocks is permitted.) Applying all the same models as discussed above, the user can determine coordinates, clock variations and tropospheric delays for an isolated, single receiver [ 39 ].”
MethodAltamimi, Z., Sillard, P., & Boucher, C. (2002) · Journal of Geophysical Research: Solid Earth · doi:10.1029/2001jb000561 · Cited by 848
Effects of antenna orientation on GPS carrier phase
Wu, J. T., Wu, S. C., Hajj, G. A., Bertiger, W. I., & Lichten, S. M. (1993) · manuscripta geodaetica · doi:10.1007/bf03655303 · Cited by 735
TEQC: The Multi-Purpose Toolkit for GPS/GLONASS Data
Estey, L. H., & Meertens, C. M. (1999) · GPS Solutions · doi:10.1007/pl00012778 · Cited by 543
A GUIDE TO USING INTERNATIONAL GNSS SERVICE (IGS) PRODUCTS
Kouba, J. (2003) · Cited by 519
Accurate Time and Frequency Transfer During Common-View of a GPS Satellite
Allan, D. W., & Weiss, M. A. (1980) · 34th Annual Symposium on Frequency Control · doi:10.1109/freq.1980.200424 · Cited by 429 · cited 1×
“(Some figures in this article are in colour only in the electronic version)”
Background(1996) · Springer eBooks · doi:10.1007/bfb0117676 · Cited by 363
Beutler, G., Brockmann, E., Gurtner, W., Hugentobler, U., Mervart, L., Rothacher, M., & Verdun, A. (1994) · manuscripta geodaetica · doi:10.1007/bf03655466 · Cited by 331 · cited 1×
“Various forms have been developed to describe GPS satellite motions, from the finite-element approach of Fliegel et al [33] to the empirical model of Beutler et al [34].”
MethodMcCarthy, D. D., & Petit, G. (1996) · Defense Technical Information Center (DTIC) · Cited by 295
GPS precise point positioning using IGS orbit products
Héroux, P., & Kouba, J. (2001) · Physics and Chemistry of the Earth, Part A: Solid Earth and Geodesy · doi:10.1016/s1464-1895(01)00103-x · Cited by 292
(1976) · Australian Surveyor · doi:10.1080/00050326.1976.10440875 · Cited by 265
Strategies for high‐precision Global Positioning System orbit determination
Lichten, S. M., & Border, J. S. (1987) · Journal of Geophysical Research: Solid Earth · doi:10.1029/jb092ib12p12751 · Cited by 247
The effect of the second order GPS ionospheric correction on receiver positions
Kedar, S., Hajj, G. A., Wilson, B. D., & Heflin, M. B. (2003) · Geophysical Research Letters · doi:10.1029/2003gl017639 · Cited by 247 · cited 1×
“is, to first order, free of ionospheric effects (see [ 32 ] for a study of the second-order effect).”
BackgroundNew IGS Station and Satellite Clock Combination
Kouba, J., & Springer, T. (2001) · GPS Solutions · doi:10.1007/pl00012863 · Cited by 158 · cited 1×
“The IGS ‘classical’ clock products were changed on 5 November 2000 (GPS Week 1087) when a new combination algorithm was implemented and the clock products were expanded to include many of the receivers in the tracking network, as well as the satellites [ 47 ].”
MethodSenior, K. L., Koppang, P., & Ray, J. (2003) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2003.1209545 · Cited by 95
Self-citationIGS/BIPM pilot project: GPS carrier phase for time/frequency transfer and timescale formation
Ray, J., & Senior, K. (2003) · Metrologia · doi:10.1088/0026-1394/40/3/307 · Cited by 89
Self-citationImproved relativistic transformations in GPS
Kouba, J. (2004) · GPS Solutions · doi:10.1007/s10291-004-0102-x · Cited by 84
Assessment of GPS carrier-phase stability for time-transfer applications
Larson, K. M., Levine, J., Nelson, L. M., & Parker, T. E. (2000) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.827441 · Cited by 77 · cited 1×
“[44, 45]).”
TAI computation: study of an alternative choice for implementing an upper limit of clock weights
Thomas, C., & Azoubib, J. (1996) · Metrologia · doi:10.1088/0026-1394/33/3/5 · Cited by 42
Miniature interferometer terminals for Earth Surveying
Counselman, C. C., & Shapiro, I. I. (1979) · Journal of Geodesy · doi:10.1007/bf02523963 · Cited by 42 · cited 1×
“The recognition that GPS could be utilized to achieve geodetic accuracies several orders of magnitude better than was originally conceived is usually attributed to Counselman and Shapiro [ 29 ].”
BackgroundMiniature interferometer terminals for earth surveying
Counselman, C. C., & Shapiro, I. I. (1979) · Journal of Geodesy · doi:10.1007/bf02521086 · Cited by 39
Continuous time transfer using GPS carrier phase
Dach, R., Schildknecht, T., Springer, T. A., Dudle, G., & Prost, L. (2002) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2002.1049729 · Cited by 30 · cited 4×
“5 × 106 s USNO-PTB 6275 km RMS/2 ns 2 years Dach et al [56]”
BackgroundInfluentialUse of Geodetic Receivers for TAI
Defraigne, P., Petit, G., & Bruyninx, C. (2002) · Cited by 28
First results with a cold cesium continuous fountain resonator
Dudle, G., Joyet, A., Berthoud, P., Mileti, G., & Thomann, P. (2001) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/19.918179 · Cited by 21 · cited 2×
“For comparison, the red trend indicates the design goal for the METAS Cs fountain [53] and the blue trend is for a Sigma Tau H-maser (from Symmetricon).”
Background
Cited by
Comparison between frequency standards in Europe and the USA at the 10−15uncertainty level
Bauch, A., Achkar, J., Bize, S., Calonico, D., Dach, R., Hlavać, R., Lorini, L., Parker, T., Petit, G., Piester, D., et al. (2006) · Metrologia · doi:10.1088/0026-1394/43/1/016 · Cited by 225
Mapping the GPS multipath environment using the signal‐to‐noise ratio (SNR)
Bilich, A., & Larson, K. M. (2007) · Radio Science · doi:10.1029/2007rs003652 · Cited by 190
“Multipath error will also influence other scientific products derived from GPS observables, including timing [ Ray and Senior, 2003 ], water vapor products [Braun et al., 2001], and seismic waves [Larson et al., 2003].”
BackgroundCharacterization of periodic variations in the GPS satellite clocks
Senior, K. L., Ray, J. R., & Beard, R. L. (2008) · GPS Solutions · doi:10.1007/s10291-008-0089-9 · Cited by 189
“…generated as a dynamically weighted ensemble of the IGS clocks themselves, including a number of tracking receivers, some of which use external hydrogen-maser (H-maser), cesium (Cs), or rubidium (Rb) frequency standards in addition to the satellite clocks (Senior et al. 2003; Ray and Senior 2003).”
BackgroundMethodSelf-citationA review of time and frequency transfer methods
Levine, J. (2008) · Metrologia · doi:10.1088/0026-1394/45/6/s22 · Cited by 185
1 × 10−16frequency transfer by GPS PPP with integer ambiguity resolution
Petit, G., Kanj, A., Loyer, S., Delporte, J., Mercier, F., & Perosanz, F. (2015) · Metrologia · doi:10.1088/0026-1394/52/2/301 · Cited by 168
Metadata
- Authors
- Ray, J., & Senior, K.
- Venue
- Metrologia
- Publisher
- IOP Publishing
- Published
- 2005-04-26
- Volume
- 42
- Issue
- 4
- Pages
- 215-232
- ISSN
- 0026-1394 (ISSN-L)
- 1681-7575
- OpenAlex
- W2169321939
- Cited by
- 173
- References
- 25
- FWCI
- 26.91
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.