Cited by 44Advanced Frequency and Time StandardsScientific Measurement and Uncertainty EvaluationAdvanced Electrical Measurement Techniques

Uncertainty of a frequency comparison with distributed dead time and measurement interval offset

Open access
Yu, Dai-Hyuk, Weiss, Marc, Parker, Thomas E·2007·Metrologia

Abstract

A theory is presented for estimating the uncertainty of a frequency comparison in the presence of distributed dead time or measurement interval offset using an extension of the method of Douglas and Boulanger (1997 Proc. 11th European Frequency and Time Forum pp 345–9). The uncertainties due to the distributed dead time and lumped dead time with mixed power law noise type are calculated and compared. It is shown that the use of distributed measurements of frequencies can greatly reduce the uncertainty as compared with that of lumped measurements. When a measurement interval offset is present, two different methods are possible for the frequency estimation and uncertainty evaluation. We compare and discuss the different results for the different methods.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0026-1394/44/1/014

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • At INRIM, the redshift is calculated from a gravitational potential difference measured with a global navigation satellite system/geoid approach from the geoid model of Europe EGG2015, with an uncertainty of 3 × 10^-18 corresponding to about 3 cm in height.

    “At INRIM, the redshift is calculated from a gravitational potential difference measured with a global navigation satellite system/geoid approach from the geoid model of Europe EGG2015 80,81 , with an uncertainty of 3 × 10 -18 corresponding to about 3 cm in height.”

    From Intercontinental comparison of optical atomic clocks through very long baseline interferometry (2021) · cites this paper as [80]

    Split into 2 atoms — 0 confirmed, 0 partially supported, 0 disputed, 0 misattributed, 2 unverifiable. Expand the claim to see per-atom verdicts.

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 8 · Cited by 44

Research works printed but not linked: 10

  1. Douglas R J and Boulanger J-S 1997 Standard uncertainty for average frequency traceability Proc. 11th European Frequency and Time Forum (Neuchâtel, Switzerland) pp 345-9
  2. Azoubib J, Granveaud M and Guinot B 1977 Estimation of the scale unit duration of time scale Metrologia 13 87-93 · DOI
  3. Douglas R J and Boulanger J-S 1992 Local oscillator requirements for timekeeping in the 10 -14 τ -1/2 era Proc. 1992 IEEE Int. Frequency Control Symp. (Hershey, PA) pp 6-26
  4. Douglas R J, Boulanger J-S and Jacques C 1993 Accuracy metrics for judging time scale algorithms Proc. 25th Precise Time and Time Interval Meeting (Marina Del Ray, CA) pp 249-66 Metrologia, 44 (2007) 91-96
  5. Morris D, Douglas R J and Boulanger J-S 1994 The role of the hydrogen maser frequency transfer from cesium fountains Japan. J. Appl. Phys. 33 1659-68 · DOI
  6. Douglas R J and Boulanger J-S 1994 Frequency control of hydrogen masers using high accuracy calibration Proc. 1994 IEEE Int. Frequency Control Symp. (Boston, MA) pp 695-708
  7. Douglas R J and Boulanger J-S 1994 Mettafitting: weight optimization for least-square fitting of PTTI data Proc. 26th Precise Time and Time Interval Meeting (Reston, VA) pp 347-60
  8. Parker T E, Howe D A and Weiss M 1998 Accurate frequency comparison at the 1 × 10 -15 level Proc. 1998 IEEE Int. Frequency Control Symp. (Pasadena, CA) pp 265-72
  9. Kasdin N J and Walter T 1992 Discrete simulation of power law noise Proc. 1992 IEEE Int. Frequency Control Symp. (Hershey, PA) pp 274-83
  10. Greenhall C A 2002 FFT-based method for simulating flicker FM Proc. 34th Precise Time and Time Interval Meeting (Reston, VA) pp 481-9

Authors
Yu, D.-H., Weiss, M., & Parker, T. E.
Affiliations
  • Korea Research Institute of Standards and Science (KR)
  • National Institute of Standards and Technology (US)
Venue
Metrologia
Published
2007-02
Volume
44
Issue
1
Pages
91-96
ISSN
  • 0026-1394 (ISSN-L)
  • 1681-7575
OpenAlex
W2098371052
Cited by
44
References
8
Citations by year
2026: 1 · 2025: 5 · 2024: 1 · 2023: 2 · 2022: 4 · 2021: 4 · 2020: 7 · 2019: 2 · 2018: 2 · 2017: 5 · 2016: 1 · 2015: 2 · 2014: 1 · 2013: 1 · 2012: 1
FWCI
1.02
Type
journal article
Language
en
Open access
Locations
Metrologia (publishedVersion)
Topics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
  • Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Scientific Measurement and Uncertainty Evaluation
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Electrical Measurement Techniques
Keywords
frequency comparison, measurement uncertainty, power-law noise, frequency estimation, frequency metrology

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review