CoChat

Intercontinental comparison of optical atomic clocks through very long baseline interferometry

Open access

The DOI matches its Crossref record; 90 of the 90 references it cites were found in a registry or an index; 26 of the 45 sources its claims cite were checked for support.

Overview

CoChat Summary

TL;DR

A dedicated broadband very long baseline interferometry (VLBI) system compared the ytterbium-171 clock IT-Yb1 in Italy and the strontium-87 clock NICT-Sr1 in Japan over an 8700 km intercontinental baseline. The VLBI frequency link achieved a total uncertainty of \(2.8 \times 10^{-16}\) for the campaign, demonstrating intercontinental optical-clock comparison beyond satellite techniques.

Key findings

  • The weighted mean Yb/Sr frequency ratio measured via VLBI was \(R = f(\mathrm{Yb})/f(\mathrm{Sr}) = 1.207\,507\,039\,343\,338\,05(34)\), corresponding to a fractional deviation from recommended frequencies of \(y(\mathrm{Yb/Sr}) = 2.5(2.8) \times 10^{-16}\).
  • The VLBI link contributed \(9 \times 10^{-17}\) uncertainty for 300 h of measurement; the total campaign uncertainty was \(2.8 \times 10^{-16}\). An independent GPS integer-ambiguity precise point positioning (IPPP) link gave \(y(\mathrm{Yb/Sr}) = -3.2(4.0) \times 10^{-16}\), and the closure difference was \(y(\mathrm{VLBI-IPPP}) = 3.5(3.2) \times 10^{-16}\).
  • Ten VLBI sessions between October 2018 and February 2019 lasted 28–36 h each, included at least 400 scans and 16–25 ICRF radio sources, and had typical delay residuals of 30 ps; single-run formal frequency uncertainty was as low as \(1.5 \times 10^{-16}\).
  • The system reached a typical formal uncertainty of \(2 \times 10^{-16}\) at \(10^5\) s averaging time, with potential to reach the low \(10^{-17}\) region at 10 d if instrumentation delays, source structure, and atmospheric modelling are controlled.

Methods

  • Two transportable 2.4 m Cassegrain VLBI stations used broadband detection from 3 GHz to 14 GHz, with four 1 GHz channels at 6.0, 8.5, 10.4, and 13.3 GHz and 2048 MHz sampling per channel; a 34 m antenna in Kashima served as the hub in a node-hub observation scheme.
  • Ten sessions compared clocks between Medicina (Italy) and Koganei (Japan) over an 8700 km baseline, using local hydrogen masers, a 535 km compensated optical fibre link between Torino and Medicina, and optical frequency combs; an independent GPS IPPP link was used for confirmation.
  • Analysis used bandwidth synthesis, least-squares fitting, VMF3 atmospheric delay calibration, Gauss-Markov weighted averages, and Monte Carlo simulation for dead-time extrapolation uncertainty.

Limitations

  • The paper states that VLBI still requires optical-to-microwave conversions; source structure caused excess delay residuals for 3 of 35 observed sources, so careful radio-source selection is needed in future comparisons.
  • The paper states that intermittent operation of the optical clocks, optical link, and VLBI link required extrapolation using masers as flywheel oscillators, with typical extrapolation uncertainty of \(1 \times 10^{-15}\) per VLBI measurement, reduced to \(2.8 \times 10^{-16}\) for the last point by simultaneous operation.
  • The text makes evident that the campaign was limited to 10 sessions over about four months rather than a continuous link, that transportable nodes relied on a high-sensitivity hub antenna, and that the east-west long baseline limited sky coverage for estimating atmospheric anisotropy.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1038/s41567-020-01038-6

Cites

90 of 90 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

14 Valid · 3 Not valid · 11 Not checked · 59 Own results and interpretations

41 more claims · 4 with their cited sources checked

Create a free account to see all 87 claims and every source verdict.

See all claims — free account
  • Probably not a substantial claim. 15
  • It may state two separate claims as one. 30

Create a free account to see these claims.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 90 references

Research works printed but not linked: 3

  1. Sekido, M. et al. A broadband VLBI system using transportable stations for geodesy and metrology. J. Geodesy (in the press).
  2. Kimura, M. Development of the software correlator for the VERA system III. International VLBI Service for Geodesy and Astrometry (IVS) National Institute of Information and Communications Technology (NICT) Technology Development Center News 29, 12–14 (2008).
  3. On the definition of time scales. In Resolutions Adopted; 26th General Conference on Weights and Measures (CGPM) Resolution 2 (BIPM, 2018); https://www.bipm.org/en/cgpm-2018/

Cited by

See all 64

Metadata

Authors
Pizzocaro, M., Sekido, M., Takefuji, K., Ujihara, H., Hachisu, H., Nemitz, N., Tsutsumi, M., Kondo, T., Kawai, E., Ichikawa, R., Namba, K., Okamoto, Y., Takahashi, R., Komuro, J., Clivati, C., Bregolin, F., Barbieri, P., Mura, A., Cantoni, E., Cerretto, G., Levi, F., Maccaferri, G., Roma, M., Bortolotti, C., Negusini, M., Ricci, R., Zacchiroli, G., Roda, J., Leute, J., Petit, G., Perini, F., Calonico, D., & Ido, T.
Affiliations
  • Istituto Nazionale di Ricerca Metrologica (IT)
  • National Institute of Information and Communications Technology (JP)
  • Chinese Academy of Sciences (CN)
  • Istituto di Radioastronomia di Bologna (IT)
  • Centre National de la Recherche Scientifique (FR)
  • Bureau international des poids et mesures (FR)
Corresponding author
Sekido, Mamoru
Venue
Nature Physics
Published
2020-10-05
Volume
17
Issue
2
Pages
223-227
ISSN
  • 1745-2473 (ISSN-L)
  • 1745-2481
OpenAlex
W3092167438
Cited by
64
References
90
Citations by year
2026: 5 · 2025: 10 · 2024: 12 · 2023: 15 · 2022: 11 · 2021: 9 · 2020: 2
FWCI
3.76
Type
journal article
Language
en
Open access
Licence
Locations
  • Nature Physics (publishedVersion)
  • CINECA IRIS Institutional Research Information System (IRIS Istituto Nazionale di Ricerca Metrologica) (submittedVersion, other-oa)
  • HAL (submittedVersion, cc-by)
Funders
  • European Commission (18SIB05 ROCIT, HORIZON2020, 15SIB03 OC18, 691156)
  • Agence Nationale de la Recherche (ANR 10 LABX 48 01, ANR-10-LABX-0048, 15SIB03, 15SIB03 OC18, 10-LABX-48-01, ANR-10-LABX-48, ANR-10, ANR-10-LABX)
  • Centre National d’Etudes Spatiales
  • Ministero dell’Istruzione, dell’Università e della Ricerca
  • National Astronomical Observatory of Japan
  • National Institutes of Natural Sciences
  • National Institute of Information and Communications Technology
  • European Metrology Programme for Innovation and Research (15SIB03 “OC18”, 15SIB05 “OFTEN”, 15SIB03, 15SIB05, 18SIB05 ROCIT, 18SIB05)
Topics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
  • Physical Sciences › Computer Science › Computer Networks and Communications › Network Time Synchronization Technologies
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum Information and Cryptography
Keywords
optical atomic clocks, clock comparison, very long baseline interferometry, extragalactic radio sources, broadband detection, timekeeping, fundamental physics tests

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-12, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-12 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Intercontinental comparison of optical atomic clocks through very long baseline interferometry. https://app.cochat.ai/papers/10.1038/s41567-020-01038-6
The paper
Pizzocaro, M., Sekido, M., Takefuji, K., Ujihara, H., Hachisu, H., Nemitz, N., Tsutsumi, M., Kondo, T., Kawai, E., Ichikawa, R., Namba, K., Okamoto, Y., Takahashi, R., Komuro, J., Clivati, C., Bregolin, F., Barbieri, P., Mura, A., Cantoni, E., . . . Ido, T. (2021). Intercontinental comparison of optical atomic clocks through very long baseline interferometry. Nature Physics. https://doi.org/10.1038/s41567-020-01038-6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.