Intercontinental comparison of optical atomic clocks through very long baseline interferometry
Open accessThe DOI matches its Crossref record; 90 of the 90 references it cites were found in a registry or an index; 26 of the 45 sources its claims cite were checked for support.
Overview
CoChat Summary
TL;DR
A dedicated broadband very long baseline interferometry (VLBI) system compared the ytterbium-171 clock IT-Yb1 in Italy and the strontium-87 clock NICT-Sr1 in Japan over an 8700 km intercontinental baseline. The VLBI frequency link achieved a total uncertainty of \(2.8 \times 10^{-16}\) for the campaign, demonstrating intercontinental optical-clock comparison beyond satellite techniques.
Key findings
- The weighted mean Yb/Sr frequency ratio measured via VLBI was \(R = f(\mathrm{Yb})/f(\mathrm{Sr}) = 1.207\,507\,039\,343\,338\,05(34)\), corresponding to a fractional deviation from recommended frequencies of \(y(\mathrm{Yb/Sr}) = 2.5(2.8) \times 10^{-16}\).
- The VLBI link contributed \(9 \times 10^{-17}\) uncertainty for 300 h of measurement; the total campaign uncertainty was \(2.8 \times 10^{-16}\). An independent GPS integer-ambiguity precise point positioning (IPPP) link gave \(y(\mathrm{Yb/Sr}) = -3.2(4.0) \times 10^{-16}\), and the closure difference was \(y(\mathrm{VLBI-IPPP}) = 3.5(3.2) \times 10^{-16}\).
- Ten VLBI sessions between October 2018 and February 2019 lasted 28–36 h each, included at least 400 scans and 16–25 ICRF radio sources, and had typical delay residuals of 30 ps; single-run formal frequency uncertainty was as low as \(1.5 \times 10^{-16}\).
- The system reached a typical formal uncertainty of \(2 \times 10^{-16}\) at \(10^5\) s averaging time, with potential to reach the low \(10^{-17}\) region at 10 d if instrumentation delays, source structure, and atmospheric modelling are controlled.
Methods
- Two transportable 2.4 m Cassegrain VLBI stations used broadband detection from 3 GHz to 14 GHz, with four 1 GHz channels at 6.0, 8.5, 10.4, and 13.3 GHz and 2048 MHz sampling per channel; a 34 m antenna in Kashima served as the hub in a node-hub observation scheme.
- Ten sessions compared clocks between Medicina (Italy) and Koganei (Japan) over an 8700 km baseline, using local hydrogen masers, a 535 km compensated optical fibre link between Torino and Medicina, and optical frequency combs; an independent GPS IPPP link was used for confirmation.
- Analysis used bandwidth synthesis, least-squares fitting, VMF3 atmospheric delay calibration, Gauss-Markov weighted averages, and Monte Carlo simulation for dead-time extrapolation uncertainty.
Limitations
- The paper states that VLBI still requires optical-to-microwave conversions; source structure caused excess delay residuals for 3 of 35 observed sources, so careful radio-source selection is needed in future comparisons.
- The paper states that intermittent operation of the optical clocks, optical link, and VLBI link required extrapolation using masers as flywheel oscillators, with typical extrapolation uncertainty of \(1 \times 10^{-15}\) per VLBI measurement, reduced to \(2.8 \times 10^{-16}\) for the last point by simultaneous operation.
- The text makes evident that the campaign was limited to 10 sessions over about four months rather than a continuous link, that transportable nodes relied on a high-sensitivity hub antenna, and that the east-west long baseline limited sky coverage for estimating atmospheric anisotropy.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
14 Valid · 3 Not valid · 11 Not checked · 59 Own results and interpretations
Every source the paper cites for this claim was checked and supports it.
In the paper
“However, they have not reached a transoceanic scale 19 and therefore intercontinental comparisons are only possible by microwave satellite transfer techniques 20 .”
§ ISTITUTO NAZIONALE DI RICERCA METROLOGICA Repository Istituzionale Intercontinental comparison of optical atomic clocks through very long baseline interferometry > Intercontinental comparison of optical atomic clocks via very long baseline interferometry
What the sources say
- Supportedcites [20] Hachisu, H. et al. Direct comparison of optical lattice clocks with an intercontinental baseline of 9,000 km. Opt. Lett. 39, 4072–4075 (2014). source
The introduction (p. 1) says that satellite-based techniques were then the only way to bridge intercontinental distances. The methods (p. 2) describe the paper’s intercontinental satellite transfer using microwave signals, matching the claim in its contemporary context. (LLM, conf=0.92)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“Optical fibre links have been shown to allow comparisons at the full accuracy of the clocks up to thousands of kilometres 18 .”
§ ISTITUTO NAZIONALE DI RICERCA METROLOGICA Repository Istituzionale Intercontinental comparison of optical atomic clocks through very long baseline interferometry > Intercontinental comparison of optical atomic clocks via very long baseline interferometry
What the sources say
- Supportedcites [18] Lisdat, C. et al. A clock network for geodesy and fundamental science. Nat. Commun. 7, 12443 (2016). source
The Abstract reports a comparison of two optical clocks over 1,415 km of telecom fibre and says it was limited only by the clocks’ own instability and uncertainty, with negligible contribution from the optical frequency transfer. This supports comparisons at the clocks’ full accuracy over a distance exceeding a thousand kilometres. (LLM, conf=0.94)
boostedstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“However, they have not reached a transoceanic scale 19 and therefore intercontinental comparisons are only possible by microwave satellite transfer techniques 20 .”
§ ISTITUTO NAZIONALE DI RICERCA METROLOGICA Repository Istituzionale Intercontinental comparison of optical atomic clocks through very long baseline interferometry > Intercontinental comparison of optical atomic clocks via very long baseline interferometry
What the sources say
- Supportedcites [19] Clivati, C. et al. Optical frequency transfer over submarine fiber links. Optica 5, 893–901 (2018). source
The Introduction (p. 2) describes bridging transoceanic distances by fiber frequency transfer as an outstanding challenge. The paper reports experiments on Mediterranean links of 96.4 km and 117.5 km (Introduction, p. 3), while treating transoceanic performance as a prediction rather than a demonstrated link. (LLM, conf=0.94)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“We used this VLBI frequency link to compare two optical clocks: the ytterbium-171 optical lattice clock 34 IT-Yb1 at INRIM in Torino (Italy) and the strontium-87 optical lattice clock 35,36 NICT-Sr1 in Koganei.”
§ ISTITUTO NAZIONALE DI RICERCA METROLOGICA Repository Istituzionale Intercontinental comparison of optical atomic clocks through very long baseline interferometry > Very long baseline interferometry (VLBI) is a technique developed for
What the sources say
- Supportedcites [34] Pizzocaro, M. et al. Absolute frequency measurement of the 1S0–3P0 transition of 171Yb with a link to international atomic time. Metrologia 57, 035007 (2020). source
Reference 34 is attached to IT-Yb1, not to the citing authors’ statement that they used a VLBI link. The source describes its own ytterbium-171 optical lattice frequency standard in the Experiment overview and identifies INRIM measurements in the Conclusions. It therefore supports the clock-identification citation; the VLBI comparison is the citing authors’ own work. (LLM, conf=0.88)
- Supportedcites [35] Hachisu, H., Petit, G., Nakagawa, F., Hanado, Y. & Ido, T. SI-traceable measurement of an optical frequency at the low 1 × 10−16 level without a local primary standard. Opt. Express 25, 8511–8523 (2017). source
The citation is attached to the identification of the NICT strontium-87 lattice clock, not to the citing authors’ statement that they used a VLBI link. The title and affiliation block (p. 1) place this paper’s strontium-clock work at NICT in Koganei, and the Experimental setup (p. 6) describes its Sr lattice clock. (LLM, conf=0.88)
- Supportedcites [36] Hachisu, H., Nakagawa, F., Hanado, Y. & Ido, T. Months-long real-time generation of a time scale based on an optical clock. Sci. Rep. 8, 4243 (2018). source
The citation is attached to the identification of NICT-Sr1, not to the citing authors’ statement that they used a VLBI link. The Methods section (“Sr lattice clock”; page unavailable) identifies NICT-Sr1 as the ⁸⁷Sr lattice clock operated in this work. The source does not document the citing authors’ VLBI comparison, but that is not the part attributed to it. (LLM, conf=0.91)
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The gravitational redshift induced by the different gravitational potential at the position of the optical clocks 34,35 has been accounted for in the clock systematic shifts, bringing a relative correction of -1.765(2) × 10 -14 to the frequency ratio.”
§ ISTITUTO NAZIONALE DI RICERCA METROLOGICA Repository Istituzionale Intercontinental comparison of optical atomic clocks through very long baseline interferometry > Very long baseline interferometry (VLBI) is a technique developed for
What the sources say
- Partly supportedcites [34] Pizzocaro, M. et al. Absolute frequency measurement of the 1S0–3P0 transition of 171Yb with a link to international atomic time. Metrologia 57, 035007 (2020). sourceExperimental — accuracy not yet measured
Split into 2 atoms — 0 confirmed, 2 partially supported, 0 disputed, 0 misattributed, 0 unverifiable. Expand the claim to see per-atom verdicts.
- Partly supportedcites [35] Hachisu, H., Petit, G., Nakagawa, F., Hanado, Y. & Ido, T. SI-traceable measurement of an optical frequency at the low 1 × 10−16 level without a local primary standard. Opt. Express 25, 8511–8523 (2017). sourceExperimental — accuracy not yet measured
Split into 2 atoms — 0 confirmed, 1 partially supported, 0 disputed, 0 misattributed, 0 unverifiable, 1 not checked. Expand the claim to see per-atom verdicts.
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
41 more claims · 4 with their cited sources checked
Create a free account to see all 87 claims and every source verdict.
- Probably not a substantial claim. 15
- It may state two separate claims as one. 30
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Using an integration time of 1 day, an uncertainty of 10 -15 can result from evaluating the satellite signal ' s carrier phase.”
From Time transfer and significance of vertical land motion in relativistic geodesy applications: a review paper (2023) · cites this paper as Pizzocaro et al., 2020
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Based on this method, over intracontinental distances, the statistical relative frequency instability of a frequency comparison has been reported to be about 10 -15 .”
From Time transfer and significance of vertical land motion in relativistic geodesy applications: a review paper (2023) · cites this paper as Pizzocaro et al., 2020
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“However, the performance of the intracontinental and intercontinental clock networks is different, as the uncertainty of the distant atomic clocks is further restricted in the intercontinental networks by the satellite transfer technique performance”
From Time transfer and significance of vertical land motion in relativistic geodesy applications: a review paper (2023) · cites this paper as Pizzocaro et al., 2020
The cited source says what the claim attributes to it.
In the citing paper
“Pizzocaro et al. (2020) showed that it is possible to reach 10 -17 uncertainty level.”
From Time transfer and significance of vertical land motion in relativistic geodesy applications: a review paper (2023) · cites this paper as Pizzocaro et al. (2020)
Citations
Cites
Optimization by Vector Space Methods
(1970) · Students Quarterly Journal · doi:10.1049/sqj.1970.0088 · Cited by 6,004
First M87 Event Horizon Telescope Results. I. The Shadow of the Supermassive Black Hole
The Event Horizon Telescope Collaboration, Akiyama, K., Alberdi, A., Alef, W., Asada, K., Azulay, R., Baczko, A.-K., Ball, D., Baloković, M., Barrett, J., et al. (2019) · The Astrophysical Journal Letters · doi:10.3847/2041-8213/ab0ec7 · Cited by 4,205
Atmospheric Correction for the Troposphere and Stratosphere in Radio Ranging Satellites
Saastamoinen, J. (2013) · Geophysical Monograph Series · doi:10.1029/gm015p0247 · Cited by 1,492
Boehm, J., Werl, B., & Schuh, H. (2006) · Journal of Geophysical Research: Solid Earth · doi:10.1029/2005jb003629 · Cited by 1,233
An optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073
Takamoto, M., Hong, F.-L., Higashi, R., & Katori, H. (2005) · Nature · doi:10.1038/nature03541 · Cited by 853
Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780
Kómár, P., Kessler, E. M., Bishof, M., Jiang, L., Sørensen, A. S., Ye, J., & Lukin, M. D. (2014) · Nature Physics · doi:10.1038/nphys3000 · Cited by 768
Atomic clock performance enabling geodesy below the centimetre level
McGrew, W. F., Zhang, X., Fasano, R. J., Schäffer, S. A., Beloy, K., Nicolodi, D., Brown, R. C., Hinkley, N., Milani, G., Schioppo, M., et al. (2018) · Nature · doi:10.1038/s41586-018-0738-2 · Cited by 727
(2019) · doi:10.1103/physrevlett.123.033201 · Cited by 711
Research works printed but not linked: 3
- Sekido, M. et al. A broadband VLBI system using transportable stations for geodesy and metrology. J. Geodesy (in the press).
- Kimura, M. Development of the software correlator for the VERA system III. International VLBI Service for Geodesy and Astrometry (IVS) National Institute of Information and Communications Technology (NICT) Technology Development Center News 29, 12–14 (2008).
- On the definition of time scales. In Resolutions Adopted; 26th General Conference on Weights and Measures (CGPM) Resolution 2 (BIPM, 2018); https://www.bipm.org/en/cgpm-2018/
Cited by
Roadmap towards the redefinition of the second
Dimarcq, N., Gertsvolf, M., Mileti, G., Bize, S., Oates, C. W., Peik, E., Calonico, D., Ido, T., Tavella, P., Meynadier, F., et al. (2023) · Metrologia · doi:10.1088/1681-7575/ad17d2 · Cited by 205
“Using VLBI, the frequency of an Yb and a Sr optical standard has been compared [75], with a statistical uncertainty from the VLBI link of 9 × 10 − 17 over 300 h of measurements.”
MethodSelf-citationSchioppo, M., Kronjäger, J., Silva, A., Ilieva, R., Paterson, J. W., Baynham, C. F. A., Bowden, W., Hill, I. R., Hobson, R., Vianello, A., et al. (2022) · Nature Communications · doi:10.1038/s41467-021-27884-3 · Cited by 118
Sub-10–16 accuracy GNSS frequency transfer with IPPP
Petit, G. (2021) · GPS Solutions · doi:10.1007/s10291-020-01062-2 · Cited by 84
Self-citationUltrastable microwave and soliton-pulse generation from fibre-photonic-stabilized microcombs
Kwon, D., Jeong, D., Jeon, I., Lee, H., & Kim, J. (2022) · Nature Communications · doi:10.1038/s41467-022-27992-8 · Cited by 86
Absolute frequency measurement of the 171Yb optical lattice clock at KRISS using TAI for over a year
Kim, H., Heo, M.-S., Park, C. Y., Yu, D.-H., & Lee, W.-K. (2021) · Metrologia · doi:10.1088/1681-7575/ac1950 · Cited by 50
“The absolute frequency measurements of the 1S0-3P0 transition of 171Yb have been performed many times by laboratories worldwide by using TAI (International Atomic Time) [13, 25-31], by using a local Cs fountain clock [20, 32], or by using the frequency ratio measurement between different atomic species [17, 33-42].”
Metadata
- Authors
- Pizzocaro, M., Sekido, M., Takefuji, K., Ujihara, H., Hachisu, H., Nemitz, N., Tsutsumi, M., Kondo, T., Kawai, E., Ichikawa, R., Namba, K., Okamoto, Y., Takahashi, R., Komuro, J., Clivati, C., Bregolin, F., Barbieri, P., Mura, A., Cantoni, E., Cerretto, G., Levi, F., Maccaferri, G., Roma, M., Bortolotti, C., Negusini, M., Ricci, R., Zacchiroli, G., Roda, J., Leute, J., Petit, G., Perini, F., Calonico, D., & Ido, T.
- Affiliations
- Istituto Nazionale di Ricerca Metrologica (IT)
- National Institute of Information and Communications Technology (JP)
- Chinese Academy of Sciences (CN)
- Istituto di Radioastronomia di Bologna (IT)
- Centre National de la Recherche Scientifique (FR)
- Bureau international des poids et mesures (FR)
- Corresponding author
- Sekido, Mamoru
- ORCID
- Pizzocaro, Marco
- Sekido, Mamoru
- Takefuji, Kazuhiro
- Ujihara, Hideki
- Hachisu, Hidekazu
- Nemitz, Nils
- Kondo, Tetsuro
- Kawai, Eiji
- Clivati, Cecilia
- Bregolin, Filippo
- Mura, Alberto
- Cantoni, Elena
- Cerretto, Giancarlo
- Levi, Filippo
- Maccaferri, Giuseppe
- Roma, Mauro
- Bortolotti, Claudio
- Negusini, Monia
- Ricci, Roberto
- Zacchiroli, Giampaolo
- Roda, Juri
- Petit, Gérard
- Perini, Federico
- Calonico, Davide
- Ido, Tetsuya
- Venue
- Nature Physics
- Published
- 2020-10-05
- Volume
- 17
- Issue
- 2
- Pages
- 223-227
- ISSN
- 1745-2473 (ISSN-L)
- 1745-2481
- OpenAlex
- W3092167438
- Cited by
- 64
- References
- 90
- Citations by year
- 2026: 5 · 2025: 10 · 2024: 12 · 2023: 15 · 2022: 11 · 2021: 9 · 2020: 2
- FWCI
- 3.76
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- other-oa
- www.springer.com/tdm (tdm)
- www.springer.com/tdm (vor)
- Locations
- Nature Physics (publishedVersion)
- CINECA IRIS Institutional Research Information System (IRIS Istituto Nazionale di Ricerca Metrologica) (submittedVersion, other-oa)
- HAL (submittedVersion, cc-by)
- Funders
- European Commission (18SIB05 ROCIT, HORIZON2020, 15SIB03 OC18, 691156)
- Agence Nationale de la Recherche (ANR 10 LABX 48 01, ANR-10-LABX-0048, 15SIB03, 15SIB03 OC18, 10-LABX-48-01, ANR-10-LABX-48, ANR-10, ANR-10-LABX)
- Centre National d’Etudes Spatiales
- Ministero dell’Istruzione, dell’Università e della Ricerca
- National Astronomical Observatory of Japan
- National Institutes of Natural Sciences
- National Institute of Information and Communications Technology
- European Metrology Programme for Innovation and Research (15SIB03 “OC18”, 15SIB05 “OFTEN”, 15SIB03, 15SIB05, 18SIB05 ROCIT, 18SIB05)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Computer Science › Computer Networks and Communications › Network Time Synchronization Technologies
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum Information and Cryptography
- Keywords
- optical atomic clocks, clock comparison, very long baseline interferometry, extragalactic radio sources, broadband detection, timekeeping, fundamental physics tests
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-12, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-12 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intercontinental comparison of optical atomic clocks through very long baseline interferometry. https://app.cochat.ai/papers/10.1038/s41567-020-01038-6
- The paper
- Pizzocaro, M., Sekido, M., Takefuji, K., Ujihara, H., Hachisu, H., Nemitz, N., Tsutsumi, M., Kondo, T., Kawai, E., Ichikawa, R., Namba, K., Okamoto, Y., Takahashi, R., Komuro, J., Clivati, C., Bregolin, F., Barbieri, P., Mura, A., Cantoni, E., . . . Ido, T. (2021). Intercontinental comparison of optical atomic clocks through very long baseline interferometry. Nature Physics. https://doi.org/10.1038/s41567-020-01038-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.