Cited by 10

The DOI matches its Crossref record.

Broadband emissivity calibration of highly reflective samples at cryogenic temperatures

Woods, S I, Jung, T M, Ly, G T, Yu, J·2012·Metrologia

Abstract

We have developed a technique for measuring the broadband optical emissivity of high reflectivity samples at cryogenic temperatures. This measurement method employs a primary standard optical detector with high absorptance from visible wavelengths to beyond 200 µm. Background subtraction and quantification allow determination of the emissivity with total absolute uncertainty (k = 1) between approximately 0.0002 and 0.002 (for emissivities between 0.0035 and 0.092) over the temperature range from 80 K to 300 K. Using the irradiance data at the detector, precise measurements of the experimental geometry and diffraction calculations, the optical power emitted by the sample can be determined. Contact thermometry measurements for the sample can then be used to find its emissivity. The emissivity calibration technique is demonstrated for large plate samples made from polished stainless steel and is also extended to calculate the separate emissivities of multiple distinct regions on a more complex sample assembly.

Overview

Integrity signals

Registry

Crossref · 10.1088/0026-1394/49/6/737

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Woods et al. (2012) at NIST developed a low-uncertainty, absolutely calibrated emissivity measurement system for the precise characterization of highly reflective materials.

    “In 2012, Woods et al. [48] at the National Institute of Standards and Technology (NIST) developed a low-uncertainty, absolutely calibrated emissivity measurement system for the precise characterization of highly reflective materials.”
  • By incorporating shutter-partitioning technology, the Woods et al. system allowed independent emissivity measurements of multiple microregions on the same sample surface.

    “By incorporating shutterpartitioning technology, it allowed independent emissivity measurements of multiple microregions on the same sample surface.”
  • The Woods et al. system enabled precise emissivity measurements of polished 304 stainless steel across the 80-300 K temperature range.

    “Based on the radiometric method, this system enabled precise emissivity measurements of polished 304 stainless steel across the 80-300 K temperature range [38].”
  • The Woods et al. apparatus employed a helium-cooled, high-absorption, low-noise absolute cryogenic radiometer as the detector.

    “The apparatus employed a heliumcooled, high-absorption, low-noise absolute cryogenic radiometer as the detector.”

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 14

  1. Ageladarakis P A Obert W DewHughes D, 1998, Cryogenic Engineering Conf. 1998, 715
  2. Lipa M Martinez A Lacroix B Chatain D, 2009, 23rd IEEE/NPSS Symp. on Fusion Engineering, 603
  3. 10.1016/j.cryogenics.2008.07.007 · DOI · Paper page
  4. 10.1117/12.624002 · DOI
  5. 10.1117/12.624020 · DOI
  6. 10.1016/j.cryogenics.2004.11.010 · DOI · Paper page
  7. 10.1364/JOSA.69.001384 · DOI
  8. 10.1364/AO.31.007219 · DOI
  9. Houston J M, 2006, Metrologia, 43, S31, 10.1088/0026-1394/43/2/S07 · DOI
  10. 10.1364/AO.44.000871 · DOI
  11. 10.1364/AO.40.004463 · DOI
  12. 10.1016/S1079-4042(05)41009-7 · DOI
  13. 10.1016/S1079-4042(05)41001-2 · DOI
  14. 10.1364/JOSA.68.001505 · DOI

Cited by

Sorted by citations

Metadata

Authors
Woods, S. I., Jung, T. M., Ly, G. T., & Yu, J.
Venue
Metrologia
Published
2012-10-15
Volume
49
Issue
6
Pages
737-744
ISSN
  • 0026-1394
  • 1681-7575
Cited by
10
References
0

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review