CoChat

Time transfer through optical fibres over a distance of 73 km with an uncertainty below 100 ps

Open access
Rost, M, Piester, D, Yang, W, Feldmann, T, Wübbena, T, Bauch, A · 2012 · Metrologia
Cited by 117

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

We demonstrate the capability of accurate time transfer using optical fibers over long distances utilizing a dark fiber and hardware which is usually employed in two-way satellite time and frequency transfer (TWSTFT). Our time transfer through optical fiber (TTTOF) system is a variant of the standard TWSTFT by employing an optical fiber in the transmission path instead of free-space transmission of signals between two ground stations through geostationary satellites. As we use a dark fiber there are practically no limitations to the bandwidth of the transmitted signals so that we can use the highest chip-rate of the binary phase-shift modulation available from the commercial equipment. This leads to an enhanced precision compared to satellite time transfer where the occupied bandwidth is limited for cost reasons. The TTTOF system has been characterized and calibrated in a common clock experiment at PTB, and the combined calibration uncertainty is estimated as 74 ps. In a second step the remote part of the system was operated at Leibniz Universitaet Hannover, Institut fuer Quantenoptik (IQ) separated by 73 km from PTB in Braunschweig. In parallel, a GPS time transfer link between Braunschweig and Hannover was established, and both links connected a passive hydrogen maser at IQ with the reference time scale UTC(PTB) maintained in PTB. The results obtained with both links agree within the 1-sigma uncertainty of the GPS link results, which is estimated as 0.72 ns. The fiber link exhibits a nearly 10-fold improved stability compared to the GPS link, and assessment of its performance has been limited by the properties of the passive maser.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0026-1394/49/6/772

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 117

Metadata

Authors
Rost, M., Piester, D., Yang, W., Feldmann, T., Wübbena, T., & Bauch, A.
Venue
Metrologia
Published
2012-10-30
Volume
49
Issue
6
Pages
772-778
ISSN
  • 0026-1394 (ISSN-L)
  • 1681-7575
OpenAlex
W2951133713
Cited by
117
References
3
FWCI
4.82
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Time transfer through optical fibres over a distance of 73 km with an uncertainty below 100 ps. https://app.cochat.ai/papers/10.1088/0026-1394/49/6/772
The paper
Rost, M., Piester, D., Yang, W., Feldmann, T., Wübbena, T., & Bauch, A. (2012). Time transfer through optical fibres over a distance of 73 km with an uncertainty below 100 ps. Metrologia. https://doi.org/10.1088/0026-1394/49/6/772

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.