Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 203

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Dissemination of time and RF frequency via a stabilized fibre optic link over a distance of 420 km

Open access
Śliwczyński, Łukasz, Krehlik, Przemysław, Czubla, Albin, Buczek, Łukasz, Lipiński, Marcin · 2013 · Metrologia

Abstract

In this paper we present the results of our work concerning the long-distance fibre optic dissemination of time (1 PPS) and frequency (10 MHz) signals generated by atomic sources, such as caesium clocks, hydrogen masers or caesium fountains. For these purposes we developed dedicated hardware (a fibre optic system with active stabilization of the propagation delay and bidirectional fibre optic amplifiers) together with a procedure to enable calibration of the time transfer. Our laboratory measurements performed over fibre lengths of up to 480 km showed an Allan deviation of the order of 4 × 10 −17 , time deviation below 1 ps (both at one-day averaging) and the possibility of calibration with picosecond accuracy even for the longest from evaluated links. After successful laboratory evaluation the system was next installed on a 421.4 km long route between the Central Office of Measures (GUM) in Warsaw, Poland, and the Astrogeodynamic Observatory (AOS) in Borowiec near Poznań, Poland. Experiments comparing the UTC(PL) and UTC(AOS) atomic timescales using the fibre optic link and TTS-4 dual-frequency GNSS time transfer receivers showed that the consistency of the results is within the calibration accuracy of the GPS receivers and with much better noise performance. The field operation of the system proved its full functionality and confirmed our previous laboratory evaluation to the maximum extent possible using the methods for comparing distant clocks available at GUM and AOS.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0026-1394/50/2/133

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 203

Metadata

Authors
Śliwczyński, Ł., Krehlik, P., Czubla, A., Buczek, Ł., & Lipiński, M.
Venue
Metrologia
Published
2013-02-11
Volume
50
Issue
2
Pages
133-145
ISSN
  • 0026-1394 (ISSN-L)
  • 1681-7575
OpenAlex
W1971785090
Cited by
203
References
2
FWCI
13.19
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Dissemination of time and RF frequency via a stabilized fibre optic link over a distance of 420 km. https://app.cochat.ai/papers/10.1088/0026-1394/50/2/133
The paper
Śliwczyński, Ł., Krehlik, P., Czubla, A., Buczek, Ł., & Lipiński, M. (2013). Dissemination of time and RF frequency via a stabilized fibre optic link over a distance of 420 km. Metrologia. https://doi.org/10.1088/0026-1394/50/2/133

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.