Stability comparison of two absolute gravimeters: optical versus atomic interferometers
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
We report the direct comparison between the stabilities of two mobile absolute gravimeters of different technology: the LNE-SYRTE Cold Atom Gravimeter (CAG) and FG5X#216 of the Université du Luxembourg. These instruments rely on two different principles of operation: atomic and optical interferometry. The comparison took place in the Walferdange Underground Laboratory for Geodynamics in Luxembourg, at the beginning of the last International Comparison of Absolute Gravimeters, ICAG-2013. We analyse a 2h10 duration common measurement, and find that the CAG shows better immunity with respect to changes in the level of vibration noise, as well as a slightly better short term stability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High-precision gravity measurements using atom interferometry
Peters, A., Chung, K. Y., & Chu, S. (2001) · Metrologia · doi:10.1088/0026-1394/38/1/4 · Cited by 965
Allan, D. W. (1987) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/t-uffc.1987.26997 · Cited by 853 · cited 1×
“In this paper, we choose to analyse the stabilities of the measurements using the Allan standard deviations [19] of the corrected gravity data (figure 2).”
MethodA new generation of absolute gravimeters
Niebauer, T. M., Sasagawa, G. S., Faller, J. E., Hilt, R. L., & Klopping, F. J. (1995) · Metrologia · doi:10.1088/0026-1394/32/3/004 · Cited by 604 · cited 1×
“The most used is the state-of-the-art commercial gravimeter FG5 [1].”
BackgroundMeasurement of the gravitational acceleration of an atom with a light-pulse atom interferometer
Kasevich, M., & Chu, S. (1992) · Applied Physics B Photophysics and Laser Chemistry · doi:10.1007/bf00325375 · Cited by 550 · cited 1×
“Since the beginning of the 90’s [2], laboratories started to elaborate gravimeters using cold atoms as a test mass [3, 4, 5].”
BackgroundDemonstration of an ultrahigh-sensitivity atom-interferometry absolute gravimeter
Hu, Z.-K., Sun, B.-L., Duan, X., Zhou, M.-K., Chen, L., Zhan, S., Zhang, Q., & Luo, J. (2013) · Physical Review A · doi:10.1103/physreva.88.043610 · Cited by 442 · cited 2×
“As an example, the fountain configuration used in [17] allows to increase T up to 300 ms, to be compared with the 80 ms we use in the CAG.”
BackgroundMethodLimits to the sensitivity of a low noise compact atomic gravimeter
Le Gouët, J., Mehlstäubler, T. E., Kim, J., Merlet, S., Clairon, A., Landragin, A., & Pereira Dos Santos, F. (2008) · Applied Physics B · doi:10.1007/s00340-008-3088-1 · Cited by 294 · cited 3×
“They are based on the combination of a passive isolation and of a low noise seismometer [4, 15].”
BackgroundSelf-citationThe influence of transverse motion within an atomic gravimeter
Louchet-Chauvet, A., Farah, T., Bodart, Q., Clairon, A., Landragin, A., Merlet, S., & Santos, F. P. D. (2011) · New Journal of Physics · doi:10.1088/1367-2630/13/6/065025 · Cited by 263 · cited 1×
“This led to develop transportable instruments [6, 7, 8, 9] coming out on participation to International Comparisons of Absolute Gravimeters (ICAG) as the LNE-SYRTE Cold Atom Gravimeter (CAG) does since 2009 [10, 11].”
BackgroundSelf-citationCompact cold atom gravimeter for field applications
Bidel, Y., Carraz, O., Charrière, R., Cadoret, M., Zahzam, N., & Bresson, A. (2013) · Applied Physics Letters · doi:10.1063/1.4801756 · Cited by 205
Operating an atom interferometer beyond its linear range
Merlet, S., Gouët, J. L., Bodart, Q., Clairon, A., Landragin, A., dos Santos, F. P., & Rouchon, P. (2009) · Metrologia · doi:10.1088/0026-1394/46/1/011 · Cited by 164 · cited 3×
“They are based on the combination of a passive isolation and of a low noise seismometer [4, 15].”
BackgroundMethodSelf-citationA cold atom pyramidal gravimeter with a single laser beam
Bodart, Q., Merlet, S., Malossi, N., dos Santos, F. P., Bouyer, P., & Landragin, A. (2010) · Applied Physics Letters · doi:10.1063/1.3373917 · Cited by 160 · cited 1×
“This led to develop transportable instruments [6, 7, 8, 9] coming out on participation to International Comparisons of Absolute Gravimeters (ICAG) as the LNE-SYRTE Cold Atom Gravimeter (CAG) does since 2009 [10, 11].”
BackgroundSelf-citationComparison between two mobile absolute gravimeters: optical versus atomic interferometers
Merlet, S., Bodart, Q., Malossi, N., Landragin, A., Santos, F. P. D., Gitlein, O., & Timmen, L. (2010) · Metrologia · doi:10.1088/0026-1394/47/4/l01 · Cited by 149
Self-citationFirst gravity measurements using the mobile atom interferometer GAIN
Hauth, M., Freier, C., Schkolnik, V., Senger, A., Schmidt, M. G., & Peters, A. (2013) · Applied Physics B · doi:10.1007/s00340-013-5413-6 · Cited by 148
Theoretical tools for atom optics and interferometry
Bordé, C. (2001) · Comptes Rendus de l Académie des Sciences - Series IV - Physics-Astrophysics · doi:10.1016/s1296-2147(01)01186-6 · Cited by 135 · cited 1×
“Moreover, the sensitivity of atom gravimeters which scales as T 2 can be increased using taller vacuum chambers and larger time T between the three interogating pulses [23].”
BackgroundActive low frequency vertical vibration isolation
Hensley, J. M., Peters, A., & Chu, S. (1999) · Review of Scientific Instruments · doi:10.1063/1.1149838 · Cited by 129 · cited 1×
“Eventually, it turned into an active system [16, 9, 5], by using the signal of the seismometer to even better stabilize the position of the reference mirror.”
BackgroundJiang, Z., Pálinkáš, V, Arias, F. E., Liard, J., Merlet, S., Wilmes, H., Vitushkin, L., Robertsson, L., Tisserand, L., Pereira Dos Santos, F., et al. (2012) · Metrologia · doi:10.1088/0026-1394/49/6/666 · Cited by 113
Self-citation
Cited by
Exploring gravity with the MIGA large scale atom interferometer
Canuel, B., Bertoldi, A., Amand, L., Pozzo di Borgo, E., Chantrait, T., Danquigny, C., Dovale Álvarez, M., Fang, B., Freise, A., Geiger, R., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-32165-z · Cited by 285
Self-citationContinuous Cold-Atom Inertial Sensor with1 nrad/secRotation Stability
Dutta, I., Savoie, D., Fang, B., Venon, B., Garrido Alzar, C. L., Geiger, R., & Landragin, A. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.183003 · Cited by 284
Self-citationGeophysics From Terrestrial Time‐Variable Gravity Measurements
Van Camp, M., de Viron, O., Watlet, A., Meurers, B., Francis, O., & Caudron, C. (2017) · Reviews of Geophysics · doi:10.1002/2017rg000566 · Cited by 248
“Results from laboratory tests show that the atom gravimeters provide an accuracy and precision similar to classical ballistic gravimeters (Freier et al., 2016; Gillot et al., 2014).”
BackgroundSelf-citationMobile quantum gravity sensor with unprecedented stability
Freier, C., Hauth, M., Schkolnik, V, Leykauf, B., Schilling, M., Wziontek, H., Scherneck, H.-G., Müller, J., & Peters, A. (2016) · Journal of Physics: Conference Series · doi:10.1088/1742-6596/723/1/012050 · Cited by 245
The watt or Kibble balance: a technique for implementing the new SI definition of the unit of mass
Robinson, I. A., & Schlamminger, S. (2016) · Metrologia · doi:10.1088/0026-1394/53/5/a46 · Cited by 240
Metadata
- Authors
- Gillot, P., Francis, O., Landragin, A., Pereira Dos Santos, F., & Merlet, S.
- Venue
- Metrologia
- Publisher
- IOP Publishing
- Published
- 2014-06-25
- Volume
- 51
- Issue
- 5
- Pages
- L15-L17
- ISSN
- 0026-1394 (ISSN-L)
- 1681-7575
- OpenAlex
- W2004600120
- Cited by
- 201
- References
- 15
- FWCI
- 14.48
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.