Precise Measurement of Thermal Conductivity at High Temperatures (100–1200 K)
The DOI matches its Crossref record.
Abstract
Various absolute steady-state methods of measuring thermal conductivity can be made to yield, verifiably, experimental results accurate to within ± 2% from 100 to 1200 K, and for conductivity values from 0.1 to 5 W/cmK. This statement is substantiated by a detailed analysis of the results obtained by eight different systems in three laboratories on ten metals: Cu, Ag, Au, Pd, Pt, W, Cr, Armco Iron, and the alloys Nb-10 W and Inconel 702. The experimental systems by which these results were obtained are also briefly described. The achievement of such accuracy, however, requires that careful attention be paid to the design and operation of the experimental apparatus. In general, the thermal conductivity is computed from three parameters: the power developed in a specific heater; the temperature difference due to that heater; and a geometrical factor relating the two through the geometry of the heat flow pattern. The determination of each parameter presents problems of its own; these we outline, and present solutions to them which are often a matter of judicious compromises. However, because the individual problems are not equally severe for the different methods here discussed, the close agreement of the results that we show provides a gratifying reassurance that the experimental approaches and theoretical analysis, including estimates of error, are basically sound.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The proposed procedure is equivalent to the correction of measured results with the absolute method by Laubitz [11, 12].”
From A correction scheme for thermal conductivity measurement using the comparative cut-bar technique based on 3D numerical simulation (2014) · cites this paper as [11]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 23
- US National Bureau of Standards, 1966, Thermal Conductivity of Selected Materials
- US National Bureau of Standards, 1968, Thermal Conductivity of Selected Materials
- Goff J F, 1970, Phys. Rev., B1, 1351, 10.1103/PhysRevB.1.1351 · doi:10.1103/physrevb.1.1351
- Goff J F, 1968, Proceedings of the Seventh Conference on Thermal Conductivity, 302, 311
- Meaden G T, 1969, Phys. Rev. Lett., 23, 475, 10.1103/PhysRevLett.23.475 · doi:10.1103/physrevlett.23.475
- 10.1103/PhysRevLett.24.587 · doi:10.1103/physrevlett.24.587
- 10.1103/PhysRevLett.24.727 · doi:10.1103/physrevlett.24.727
- Tye R P Ed., 1969, Thermal Conductivity, 1
- Laubitz M J, 1969, Can. J. Phys., 47, 2633, 10.1139/p69-322 · DOI
- Forbes J D, 1864, Trans. Roy. Soc. Edinburg, 23, 133, 10.1017/S0080456800018494 · doi:10.1017/s0080456800018494
- Watson T W, 1961, Trans. ASME J. Heat Transfer, 83C, 403, 10.1115/1.3683651 · doi:10.1115/1.3683651
- Godfrey T G, 1965, J. Am. Ceram. Soc., 48, 297, 10.1111/j.1151-2916.1965.tb14745.x · DOI
- Fulkerson W, 1966, J. Appl. Phys., 37, 2639, 10.1063/1.1782098 · DOI
- Flynn D R, 1967, J. Res. Nat. Bur. Stand., 71C, 255, 10.6028/jres.071C.021 · doi:10.6028/jres.071c.021
- Laubitz M J, 1967, Can. J. Phys., 45, 3677, 10.1139/p67-309 · DOI
- Moore J P, 1967, Can. J. Phys., 45, 3849, 10.1139/p67-323 · DOI
- Cook J G, 1970, Can. J. Phys., 48, 254, 10.1139/p70-035 · DOI · Paper page
- Matsumura T, 1970, Can. J. Phys., 48, 1499, 10.1139/p70-189 · DOI
- Laubitz M J, 1960, Can. J. Phys., 38, 887, 10.1139/p60-098 · doi:10.1139/p60-098
- Watson T W, 1967, J. Res. Nat. Bur. Stand., 71C, 285, 10.6028/jres.071C.022 · doi:10.6028/jres.071c.022
- Laubitz M J, 1964, Can. J. Phys., 42, 131, 10.1139/p64-011 · DOI
- Watson T W, 1968, Trans. Met. Soc. AIME, 242, 844
- 10.1016/0022-5088(67)90062-8 · DOI
Cited by
Thermal conductivity of metals and alloys
Klemens, P. G., & Williams, R. K. (1986) · International Materials Reviews · doi:10.1179/095066086790324294 · Cited by 229
Thermal conductivity of metals and alloys
Klemens, P. G., & Williams, R. K. (1986) · International Metals Reviews · doi:10.1179/imtr.1986.31.1.197 · Cited by 182
Design and Validation of a High-Temperature Comparative Thermal-Conductivity Measurement System
Jensen, C., Xing, C., Folsom, C., Ban, H., & Phillips, J. (2012) · International Journal of Thermophysics · doi:10.1007/s10765-012-1161-9 · Cited by 31
Xing, C., Folsom, C., Jensen, C., Ban, H., & Marshall, D. W. (2014) · Measurement Science and Technology · doi:10.1088/0957-0233/25/5/055602 · Cited by 9
Metadata
- Authors
- Laubitz, M. J., & McElroy, D. L.
- Venue
- Metrologia
- Publisher
- IOP Publishing
- Published
- 1971-01
- Volume
- 7
- Issue
- 1
- Pages
- 1-15
- ISSN
- 0026-1394
- 1681-7575
- Cited by
- 48
- References
- 0
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Precise Measurement of Thermal Conductivity at High Temperatures (100–1200 K). https://app.cochat.ai/papers/10.1088/0026-1394/7/1/002
- The paper
- Laubitz, M. J., & McElroy, D. L. (1971). Precise Measurement of Thermal Conductivity at High Temperatures (100–1200 K). Metrologia. https://doi.org/10.1088/0026-1394/7/1/002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.