Reconstruction of densities from their projections, with applications in radiological physics
Open accessThe DOI matches its Crossref record.
Abstract
The precise determination of body attenuation for X-rays or its stopping power for heavy charged particles, positron annihilation scanning, and, to a lesser extent, single gamma -ray scanning all contain the same mathematical problem, namely, to determine a density distribution in space from its known projections on to one or more planes. Present methods of solving this problem involve taking slices through the distribution and considering the projected densities to be line integrals along lines through the slices and then using Fourier transforms, or orthogonal expansions of the line integrals, or a matrix inversion to determine the density distribution. An alternative method enables the density to be inferred by integration. In addition, a generalization of the method to surface integrals is given and possible applications are suggested including an application to positron annihilation scanning.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Whole-Brain Imaging with Single-Cell Resolution Using Chemical Cocktails and Computational Analysis
Susaki, E. A., Tainaka, K., Perrin, D., Kishino, F., Tawara, T., Watanabe, T. M., Yokoyama, C., Onoe, H., Eguchi, M., Yamaguchi, S., et al. (2014) · Cell · doi:10.1016/j.cell.2014.03.042 · Cited by 1,325
The neural basis of the blood–oxygen–level–dependent functional magnetic resonance imaging signal
Logothetis, N. K. (2002) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.2002.1114 · Cited by 958
A Positron-Emission Transaxial Tomograph for Nuclear Imaging (PETT)
Ter-Pogossian, M. M., Phelps, M. E., Hoffman, E. J., & Mullani, N. A. (1975) · Radiology · doi:10.1148/114.1.89 · Cited by 680
Behind the scenes of functional brain imaging: A historical and physiological perspective
Raichle, M. E. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.3.765 · Cited by 616
Radermacher, M., Wagenknecht, T., Verschoor, A., & Frank, J. (1987) · Journal of Microscopy · doi:10.1111/j.1365-2818.1987.tb01333.x · Cited by 501
High resolution X-ray computed tomography: an emerging tool for small animal cancer research
Paulus, M. J., Gleason, S. S., Kennel, S. J., Hunsicker, P. R., & Johnson, D. K. (2000) · Neoplasia · doi:10.1038/sj.neo.7900069 · Cited by 490
Digital reconstruction of multidimensional signals from their projections
Mersereau, R. M., & Oppenheim, A. V. (1974) · Proceedings of the IEEE · doi:10.1109/proc.1974.9625 · Cited by 435
Three-Dimensional Reconstruction from Projections: A Review of Algorithms
Gordon, R., & Herman, G. (1974) · International Review of Cytology · doi:10.1016/s0074-7696(08)60925-0 · Cited by 335
Electron Tomography: A Three‐Dimensional Analytic Tool for Hard and Soft Materials Research
Ercius, P., Alaidi, O., Rames, M. J., & Ren, G. (2015) · Advanced Materials · doi:10.1002/adma.201501015 · Cited by 226
Metadata
- Authors
- Cormack, A. M.
- Venue
- Physics in Medicine & Biology
- Publisher
- IOP Publishing
- Published
- 1973-03-01
- Volume
- 18
- Issue
- 2
- Pages
- 195-207
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2058995634
- Cited by
- 212
- References
- 0
- FWCI
- 9.63
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.