The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Electron beam dose calculations
Abstract
Electron beam dose distributions in the presence of inhomogeneous tissue are calculated by an algorithm that sums the dose distribution of individual pencil beams. The off-axis dependence of the pencil beam dose distribution is described by the Fermi-Eyges theory of thick-target multiple Coulomb scattering. Measured square-field depth-dose data serve as input for the calculations. Air gap corrections are incorporated and use data from'in-air' measurements in the penumbra of the beam. The effective depth, used to evaluate depth-dose, and the sigma of the off-axis Gaussian spread against depth are calculated by recursion relations from a CT data matrix for the material underlying individual pencil beams. The correlation of CT number with relative linear stopping power and relative linear scattering power for various tissues is shown. The results of calculations are verified by comparison with measurements in a 17 MeV electron beam from the Therac 20 linear accelerator. Calculated isodose lines agree nominally to within 2 mm of measurements in a water phantom. Similar agreement is observed in cork slabs simulating lung. Calculations beneath a bone substitute illustrate a weakness in the calculation. Finally a case of carcinoma in the maxillary antrum is studied. The theory suggests an alternative method for the calculation of depth-dose of rectangular fields.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hubbell, J. H. (1969) · doi:10.6028/nbs.nsrds.29 · Cited by 598
The direct use of CT numbers in radiotherapy dosage calculations for inhomogeneous media
Parker, R. P., Hobday, P., & Cassell, K. J. (1979) · Physics in Medicine and Biology · doi:10.1088/0031-9155/24/4/011 · Cited by 101
Cited by
Schneider, W., Bortfeld, T., & Schlegel, W. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/2/314 · Cited by 831
Newhauser, W. D., & Zhang, R. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/8/r155 · Cited by 675
Optimisation of conformal radiotherapy dose distribution by simulated annealing
Webb, S. (1989) · Physics in Medicine and Biology · doi:10.1088/0031-9155/34/10/002 · Cited by 339
Metadata
- Authors
- Hogstrom, K. R., Mills, M. D., & Almond, P. R.
- Venue
- Physics in Medicine & Biology
- Publisher
- IOP Publishing
- Published
- 1981-05-01
- Volume
- 26
- Issue
- 3
- Pages
- 445-459
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2014447936
- Cited by
- 352
- References
- 2
- FWCI
- 3.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electron beam dose calculations. https://app.cochat.ai/papers/10.1088/0031-9155/26/3/008
- The paper
- Hogstrom, K. R., Mills, M. D., & Almond, P. R. (1981). Electron beam dose calculations. Physics in Medicine & Biology. https://doi.org/10.1088/0031-9155/26/3/008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.