The DOI matches its Crossref record.
SNR and DQE analysis of broad spectrum X-ray imaging
Abstract
A general analysis of the signal to noise ratio SNR, of X-ray imaging with a broad spectrum is presented. The analysis indicates that the energy modulation of the signal together with its degree of matching by the energy response of the image receptor are significant determinants of the SNR for signal detection. This requires a generalisation of the interpretation of detective quantum efficiency, DQE, the transfer function appropriate from SNR, that will be dependent on the image detection or discrimination task. The generalised DQE is similar to the conventional DQE for the task of detecting radiation levels, but may differ substantially from it for the task of discriminating a lesion from its surround, particularly for signals of bone or iodine. The photon counter is shown to be inferior to the ideal detector for these tasks, but to be generally superior to the energy detecting scintillators used in conventional or digital radiography and computed tomography.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Perovskite-filled membranes for flexible and large-area direct-conversion X-ray detector arrays
Zhao, J., Zhao, L., Deng, Y., Xiao, X., Ni, Z., Xu, S., & Huang, J. (2020) · Nature Photonics · doi:10.1038/s41566-020-0678-x · Cited by 408
Radiation dose reduction in computed tomography: techniques and future perspective
Yu, L., Liu, X., Leng, S., Kofler, J. M., Ramirez-Giraldo, J. C., Qu, M., Christner, J., Fletcher, J. G., & McCollough, C. H. (2009) · Imaging in Medicine · doi:10.2217/iim.09.5 · Cited by 395
Giger, M. L., Chan, H., & Boone, J. (2008) · Medical Physics · doi:10.1118/1.3013555 · Cited by 311
Image quality in CT: From physical measurements to model observers
Verdun, F. R., Racine, D., Ott, J. G., Tapiovaara, M. J., Toroi, P., Bochud, F. O., Veldkamp, W. J. H., Schegerer, A., Bouwman, R. W., Giron, I. H., et al. (2015) · Physica Medica · doi:10.1016/j.ejmp.2015.08.007 · Cited by 300
Self-citationSpektr: A computational tool for x‐ray spectral analysis and imaging system optimization
Siewerdsen, J. H., Waese, A. M., Moseley, D. J., Richard, S., & Jaffray, D. A. (2004) · Medical Physics · doi:10.1118/1.1758350 · Cited by 279
Metadata
- Authors
- Tapiovaara, M. J., & Wagner, R.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1985-06-01
- Volume
- 30
- Issue
- 6
- Pages
- 519-529
- ISSN
- 0031-9155 (ISSN-L)
- OpenAlex
- W1973132483
- Cited by
- 228
- References
- 0
- FWCI
- 1.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: SNR and DQE analysis of broad spectrum X-ray imaging. https://app.cochat.ai/papers/10.1088/0031-9155/30/6/002
- The paper
- Tapiovaara, M. J., & Wagner, R. (1985). SNR and DQE analysis of broad spectrum X-ray imaging. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/30/6/002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.