The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Radiation dose reduction in computed tomography: techniques and future perspective
Open accessAbstract
Despite universal consensus that computed tomography (CT) overwhelmingly benefits patients when used for appropriate indications, concerns have been raised regarding the potential risk of cancer induction from CT due to the exponentially increased use of CT in medicine. Keeping radiation dose as low as reasonably achievable, consistent with the diagnostic task, remains the most important strategy for decreasing this potential risk. This article summarizes the general technical strategies that are commonly used for radiation dose management in CT. Dose-management strategies for pediatric CT, cardiac CT, dual-energy CT, CT perfusion and interventional CT are specifically discussed, and future perspectives on CT dose reduction are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT
Brenner, D. J., Elliston, C. D., Hall, E. J., & Berdon, W. E. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760289 · Cited by 3,222
Sidky, E. Y., & Pan, X. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/17/021 · Cited by 1,995
Strategies for Reducing Radiation Dose in CT
McCollough, C. H., Primak, A. N., Braun, N., Kofler, J., Yu, L., & Christner, J. (2009) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2008.10.006 · Cited by 842
Self-citationDetermination of the weighted CT dose index in modern multi-detector CT scanners
Perisinakis, K., Damilakis, J., Tzedakis, A., Papadakis, A., Theocharopoulos, N., & Gourtsoyiannis, N. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/21/010 · Cited by 47
Cited by
Kuriyan, R. (2018) · Indian Journal of Medical Research · doi:10.4103/ijmr.ijmr_1777_18 · Cited by 384
McCollough, C. H., Bartley, A. C., Carter, R. E., Chen, B., Drees, T. A., Edwards, P., Holmes, D. R., Huang, A. E., Khan, F., Leng, S., et al. (2017) · Medical Physics · doi:10.1002/mp.12345 · Cited by 308
Self-citationM., J. M., U., R., U., S. K., Shetty, L., Dabholkar, A., & Ramachandraiah, C. (2026) · Indian Journal of Radiology and Imaging · doi:10.1055/s-0045-1806868 · Cited by 2
“These methods preserve optimum image quality with dose reduction.”
Metadata
- Authors
- Yu, L., Liu, X., Leng, S., Kofler, J. M., Ramirez-Giraldo, J. C., Qu, M., Christner, J., Fletcher, J. G., & McCollough, C. H.
- Venue
- Imaging in Medicine
- Publisher
- OMICS Publishing Group
- Published
- 2009-10
- Volume
- 1
- Issue
- 1
- Pages
- 65-84
- ISSN
- 1755-5191 (ISSN-L)
- 1755-5205
- OpenAlex
- W2136172319
- Cited by
- 395
- References
- 5
- FWCI
- 7.99
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Radiation dose reduction in computed tomography: techniques and future perspective. https://app.cochat.ai/papers/10.2217/iim.09.5
- The paper
- Yu, L., Liu, X., Leng, S., Kofler, J. M., Ramirez-Giraldo, J. C., Qu, M., Christner, J., Fletcher, J. G., & McCollough, C. H. (2009). Radiation dose reduction in computed tomography: techniques and future perspective. Imaging in Medicine. https://doi.org/10.2217/iim.09.5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.