Feasibility of the homogeneous head model in the interpretation of neuromagnetic fields
Open accessThe DOI matches its Crossref record.
Abstract
During the past few years it has been demonstrated that active areas in the human brain can be located by measuring the magnetic fields arising from the electric currents in the neurons. An established model for the conductivity geometry of the head in these studies is the layerwise homogeneous sphere. If, however, the measurement grid is too large or the local radius of curvature of the head is changing rapidly in the measurement area, this simple model may become inadequate. In this paper we investigate the feasibility of replacing the conducting sphere by a homogeneous body having the shape of the brain. We show by a semi-quantitative argument that the homogeneous body model is justified. A numerical procedure for the calculation of the magnetic field is presented with examples of the accuracy that can be obtained. An example of significant differences between the predictions of the homogeneous and sphere models is discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Basic mathematical and electromagnetic concepts of the biomagnetic inverse problem
Sarvas, J. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/1/004 · Cited by 1,843
Self-citationRealistic conductivity geometry model of the human head for interpretation of neuromagnetic data
Hamalainen, M. S., & Sarvas, J. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.16463 · Cited by 989
Self-citationWolters, C. H., Anwander, A., Tricoche, X., Weinstein, D., Koch, M. A., & MacLeod, R. S. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.10.014 · Cited by 452
Mathematical framework for large-scale brain network modeling in The Virtual Brain
Sanz-Leon, P., Knock, S. A., Spiegler, A., & Jirsa, V. K. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.01.002 · Cited by 356
“These modalities include, but are not limited to, intracranial Electroencephalography (iEEG), Electroencephalography (EEG) (Nunez and Srinivasan, 1981; Nunez, 1995; Niedermeyer and Lopes Da Silva, 2005), Magnetoencephalography (MEG) (Hämäläinen and Sarvas, 1987; Hämäläinen, 1992; Hämäläinen et al., 1993) and functiona…”
InfluentialVolume conduction effects in EEG and MEG
van den Broek, S. P., Reinders, F., Donderwinkel, M., & Peters, M. J. (1998) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(97)00147-8 · Cited by 355
Metadata
- Authors
- Hamalainen, M. S., & Sarvas, J.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1987-01-01
- Volume
- 32
- Issue
- 1
- Pages
- 91-97
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2076636459
- Cited by
- 122
- References
- 0
- FWCI
- 5.36
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Feasibility of the homogeneous head model in the interpretation of neuromagnetic fields. https://app.cochat.ai/papers/10.1088/0031-9155/32/1/014
- The paper
- Hamalainen, M. S., & Sarvas, J. (1987). Feasibility of the homogeneous head model in the interpretation of neuromagnetic fields. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/32/1/014
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.