The distribution of induced currents in magnetic stimulation of the nervous system
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Magnetic stimulation of the nervous system is being used as an alternative to electrical stimulation, principally because it is painless. The spatial distribution of induced currents from the stimulating coil is calculated from a computer model with graphical output. Two configurations of a plane circular coil are considered: parallel to the tissue surface and perpendicular to the surface. The surface is assumed planar and infinite in extent. The tissue is modelled as a uniform, isotropic volume conductor. A quasi-static approximation is made in calculating the electric field. Maps of current density, J, as a function of position, including depth, are shown. In both configurations, J is always parallel to the surface, and is maximum at the surface. There is no perpendicular (vertical) current. For a one-turn 10 cm diameter coil, spaced 1 cm from conducting tissue and parallel to it, with rate of change of current 10(8) A s(-1), Jmax = 6.8 A m(-2) (assuming conductivity 0.2 omega -1 m(-1)). In the perpendicular configuration Jmax = 4.1 A m(-2). These results suggest that nerve fibres running parallel to the skin surface are more likely to be stimulated than those running obliquely; and that it is extremely difficult to stimulate nerve fibres running perpendicularly. This model can be used to characterise the performance of other shapes of stimulating coils and the dependence on fibre orientation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
NON-INVASIVE MAGNETIC STIMULATION OF HUMAN MOTOR CORTEX
Barker, A. T., Jalinous, R., & Freeston, I. L. (1985) · The Lancet · doi:10.1016/s0140-6736(85)92413-4 · Cited by 4,460
Responses in small hand muscles from magnetic stimulation of the human brain.
Hess, C. W., Mills, K. R., & Murray, N. M. (1987) · The Journal of Physiology · doi:10.1113/jphysiol.1987.sp016621 · Cited by 757
Bottomley, P. A., & Andrew, E. R. (1978) · Physics in Medicine & Biology · doi:10.1088/0031-9155/23/4/006 · Cited by 407
Stimulation of nerve trunks with time-varying magnetic fields
Polson, M. J. R., Barker, A. T., & Freeston, I. L. (1982) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441362 · Cited by 219
Rushton, W. A. H. (1927) · The Journal of Physiology · doi:10.1113/jphysiol.1927.sp002409 · Cited by 171
Roth, B. J., Cohen, L. G., Hallett, M., Friauf, W., & Basser, P. J. (1990) · Muscle & Nerve · doi:10.1002/mus.880130812 · Cited by 126
Cited by
Rossi, S., Hallett, M., Rossini, P. M., & Pascual-Leone, A. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.08.016 · Cited by 5,367
“Coil elements which are non-tangential to the scalp induce accumulation of surface charge, which reduces coil efficiency (Tofts, 1990; Branston and Tofts, 1991; Eaton, 1992).”
BackgroundPascual-Leone, A., Nguyet, D., Cohen, L. G., Brasil-Neto, J. P., Cammarota, A., & Hallett, M. (1995) · Journal of Neurophysiology · doi:10.1152/jn.1995.74.3.1037 · Cited by 1,410
Pascual-Leone, A., Rubio, B., Pallardó, F., & Catalá, M. D. (1996) · The Lancet · doi:10.1016/s0140-6736(96)01219-6 · Cited by 1,229
Deng, Z.-D., Lisanby, S. H., & Peterchev, A. V. (2013) · Brain Stimulation · doi:10.1016/j.brs.2012.02.005 · Cited by 1,073
Noninvasive Human Brain Stimulation
Wagner, T., Valero-Cabre, A., & Pascual-Leone, A. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.061206.133100 · Cited by 873
Metadata
- Authors
- Tofts, P. S.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1990-08-01
- Volume
- 35
- Issue
- 8
- Pages
- 1119-1128
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2078858378
- Cited by
- 159
- References
- 6
- FWCI
- 2.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.