The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Unproved prediction of extracellular and total body water using impedance loci generated by multiple frequency bioelectrical impedance analysis
Open accessAbstract
Bioelectrical impedance analysis (BIA) using a frequency of 50 kHz is an established method of predicting total body water (TBW). However, very little research has been performed to determine whether 50 kHz is the optimum frequency for the prediction of TBW from impedance measurements. This paper analyses a mathematical expression describing the equivalent electrical circuit for biological tissue, and derives a graphical representation of the resistive and reactive components. The nature of the resulting impedance locus was used in the analysis of measured whole-body impedance of 42 rats over a range of frequencies to determine the impedance at the characteristic frequency, Zc, and also the impedance at zero frequency, R0. The standard error associated with the prediction of TBW (determined by isotope dilution) using Zc was 5.9% compared with a standard error of prediction of 10.1% using the established BIA method at 50 kHz on the same data. Predictions of extracellular water (ECW) using the impedance at zero frequency, R0, yielded a standard error of 3.2% compared with standard errors of 4.8% and 4.2% using single frequency BIA measurements at 5 kHz and 1 kHz, respectively. These results demonstrate a significant (P < 0.01) improvement in the prediction of TBW and ECW using multiple frequency bioelectrical impedance analysis (MFBIA).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dispersion and Absorption in Dielectrics I. Alternating Current Characteristics
Cole, K. S., & Cole, R. H. (1941) · The Journal of Chemical Physics · doi:10.1063/1.1750906 · Cited by 10,152
Assessment of fat-free mass using bioelectrical impedance measurements of the human body
Lukaski, H., Johnson, P., Bolonchuk, W., & Lykken, G. (1985) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/41.4.810 · Cited by 1,896
Cited by
Bioelectrical impedance analysis?part I: review of principles and methods
KYLE, U. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.06.004 · Cited by 3,200
Bioelectrical impedance analysis—part II: utilization in clinical practice
Kyle, U. G., Bosaeus, I., De Lorenzo, A. D., Deurenberg, P., Elia, M., Manuel Gómez, J., Lilienthal Heitmann, B., Kent-Smith, L., Melchior, J.-C., Pirlich, M., et al. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.09.012 · Cited by 2,350
Human Body Composition: In Vivo Methods
Ellis, K. J. (2000) · Physiological Reviews · doi:10.1152/physrev.2000.80.2.649 · Cited by 825
Predicting body cell mass with bioimpedance by using theoretical methods: a technological review
De Lorenzo, A., Andreoli, A., Matthie, J., & Withers, P. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.82.5.1542 · Cited by 654
Ward, L. C. (2019) · European Journal of Clinical Nutrition · doi:10.1038/s41430-018-0335-3 · Cited by 417
Self-citation
Metadata
- Authors
- Cornish, B. H., Thomas, B. J., & Ward, L. C.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1993-03-01
- Volume
- 38
- Issue
- 3
- Pages
- 337-346
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W1993913057
- Cited by
- 229
- References
- 2
- FWCI
- 4.99
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Unproved prediction of extracellular and total body water using impedance loci generated by multiple frequency bioelectrical impedance analysis. https://app.cochat.ai/papers/10.1088/0031-9155/38/3/001
- The paper
- Cornish, B. H., Thomas, B. J., & Ward, L. C. (1993). Unproved prediction of extracellular and total body water using impedance loci generated by multiple frequency bioelectrical impedance analysis. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/38/3/001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.