Improvements in the calibration of109Cd K X-ray fluorescence systems for measuring bone lead in vivo
The DOI matches its Crossref record.
Abstract
A 109Cd K x-ray fluorescence (XRF) system using a point source in a back-scatter geometry is described. The suitability of plaster-of-Paris phantoms as targets for intercalibration standards was evaluated. When the phantom concentrations were measured by inductively-coupled-plasma mass spectrometry (ICPMs), the calculated phantom concentrations underestimated true concentrations by an average of 15%. Since calculated values are used to calibrate the K XRF system, in vivo bone-lead concentrations may be similarly underestimated. The difference between calculated and measured concentration is attributable to impurities in the plaster of Paris (e.g. calcium carbonate). The ICPMS-measured concentrations were used to calibrate the K XRF system. The same phantoms were also measured as 'unknowns' by a bone-lead measurement system (Abiomed, Danvers, MA, USA). The commercial system overestimated the lowest-concentration phantoms and underestimated the phantoms with concentrations above 15 microg Pb/g plaster of Paris. The commercial system and our system were compared by measurement of the new phantoms in air and in water. The K XRF system exhibited better precision in both situations. On the basis of this work, we recommend that plaster-of-Paris phantoms used to calibrate K XRF measurement systems be analysed first by ICPMS or another valid analytical technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bone lead as a biological marker in epidemiologic studies of chronic toxicity: conceptual paradigms.
Hu, H., Rabinowitz, M., & Smith, D. (1998) · Environmental Health Perspectives · doi:10.1289/ehp.981061 · Cited by 435
Self-citationHu, H., Shih, R., Rothenberg, S., & Schwartz, B. S. (2007) · Environmental Health Perspectives · doi:10.1289/ehp.9783 · Cited by 306
Self-citationInfluence of Prenatal Lead Exposure on Genomic Methylation of Cord Blood DNA
Pilsner, J. R., Hu, H., Ettinger, A., Sánchez, B. N., Wright, R. O., Cantonwine, D., Lazarus, A., Lamadrid-Figueroa, H., Mercado-García, A., Téllez-Rojo, M. M., et al. (2009) · Environmental Health Perspectives · doi:10.1289/ehp.0800497 · Cited by 275
Self-citationBiomarkers of Lead Exposure and DNA Methylation within Retrotransposons
Wright, R. O., Schwartz, J., Wright, R. J., Bollati, V., Tarantini, L., Park, S. K., Hu, H., Sparrow, D., Vokonas, P., & Baccarelli, A. (2010) · Environmental Health Perspectives · doi:10.1289/ehp.0901429 · Cited by 235
Self-citationDecrease in Birth Weight in Relation to Maternal Bone-Lead Burden
González-Cossı́o, T., Peterson, K. E., Sanı́n, L.-H., Fishbein, E., Palazuelos, E., Aro, A., Hernández-Avila, M., & Hu, H. (1997) · Pediatrics · doi:10.1542/peds.100.5.856 · Cited by 235
Self-citation
Metadata
- Authors
- Aro, A. C. A., Todd, A. C., Amarasiriwardena, C., & Hu, H.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1994-12-01
- Volume
- 39
- Issue
- 12
- Pages
- 2263-2271
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2088396931
- Cited by
- 96
- References
- 0
- FWCI
- 4.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improvements in the calibration of109Cd K X-ray fluorescence systems for measuring bone lead in vivo. https://app.cochat.ai/papers/10.1088/0031-9155/39/12/009
- The paper
- Aro, A. C. A., Todd, A. C., Amarasiriwardena, C., & Hu, H. (1994). Improvements in the calibration of109Cd K X-ray fluorescence systems for measuring bone lead in vivo. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/39/12/009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.