The importance and implementation of accurate 3D compensation methods for quantitative SPECT
Abstract
The purpose of this study was to investigate the importance of 2D versus 3D compensation methods in SPECT. The compensation methods included in the study addressed two important degrading factors, namely attenuating and collimator-detector response in SPET. They can be divided into two general categories. The conventional methods are based on the filtered backprojection algorithm, the Chang algorithm for attenuation compensation and the Metz filter for detector response compensation. These methods, which were computationally efficient, could only achieve approximate compensation due to the assumptions made. The quantitative compensation methods provide accurate compensation by modelling the degrading effects at the expense of large computational requirements. Both types of compensation methods were implemented in 2D and 3D reconstructions. The 2D and 3D reconstruction/compensation methods were evaluated using data from simulation of brain and heart, and patient thallium SPECT studies. Our results demonstrate the importance of compensation methods in improving the quality and quantitative accuracy of SPECT images and the relative effectiveness of the different 2D and 3D reconstruction/compensation methods. We concluded that 3D implementation of the quantitative compensation methods provides the best SPECT image in terms of quantitative accuracy, spatial resolution, and noise at a cost of high computational requirements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
Cited by
Medical image analysis: progress over two decades and the challenges ahead
Duncan, J. S., & Ayache, N. (2000) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.824822 · Cited by 4,140
PET versus SPECT: strengths, limitations and challenges
Rahmim, A., & Zaidi, H. (2008) · Nuclear Medicine Communications · doi:10.1097/mnm.0b013e3282f3a515 · Cited by 834
Erlandsson, K., Buvat, I., Pretorius, P. H., Thomas, B. A., & Hutton, B. F. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/21/r119 · Cited by 733
Dewaraja, Y. K., Frey, E. C., Sgouros, G., Brill, A. B., Roberson, P., Zanzonico, P. B., & Ljungberg, M. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.100123 · Cited by 419
Self-citationDorbala, S., Ananthasubramaniam, K., Armstrong, I. S., Chareonthaitawee, P., DePuey, E. G., Einstein, A. J., Gropler, R. J., Holly, T. A., Mahmarian, J. J., Park, M.-A., et al. (2018) · Journal of Nuclear Cardiology · doi:10.1007/s12350-018-1283-y · Cited by 406
Metadata
- Authors
- Tsui, B. M. W., Frey, E. C., Zhao, X., Lalush, D. S., Johnston, R. E., & McCartney, W. H.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1994-03-01
- Volume
- 39
- Issue
- 3
- Pages
- 509-530
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W1973675464
- Cited by
- 161
- References
- 1
- FWCI
- 5.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The importance and implementation of accurate 3D compensation methods for quantitative SPECT. https://app.cochat.ai/papers/10.1088/0031-9155/39/3/015
- The paper
- Tsui, B. M. W., Frey, E. C., Zhao, X., Lalush, D. S., Johnston, R. E., & McCartney, W. H. (1994). The importance and implementation of accurate 3D compensation methods for quantitative SPECT. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/39/3/015
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.