The DOI matches its Crossref record.
Optical pathlength measurements on adult head, calf and forearm and the head of the newborn infant using phase resolved optical spectroscopy
Open accessAbstract
We have used an intensity modulated optical spectrometer, which measures the phase shift across tissue experienced by intensity modulated near-infrared light, to determine the absolute optical pathlength through tissue. The instrument is portable and takes only 5 s to record pathlength at four wavelengths (690 nm, 744 nm, 807 nm and 832 nm). The absolute pathlength divided by the known spacing between the light source and detector on the skin is the differential pathlength factor (DPF) which previous studies have shown is approximately constant for spacings greater than 2.5 cm. DPF results are presented for measurements on 100 adults and 35 newborn infants to determine the statistical variation on the DPF. All measurements were made at a frequency of 200 MHz with source-detector spacings of > 4 cm. Results at 807 nm show a DPF of 4.16(+/- 18.8%) for adult arm, 5.51(+/- 18%) for adult leg, 6.26(+/- 14.1%) for adult head and 4.99(+/- 9%) for the head of a newborn infant. A wavelength dependence was obtained for DPF on all tissues and a difference in DPF between male and female was observed for both the adult arm and leg. The results can be used to improve the quantitation of chromophore concentration changes in adults and newborn infants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ferrari, M., & Quaresima, V. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.03.049 · Cited by 2,274
Boas, D. A., Dale, A. M., & Franceschini, M. A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.011 · Cited by 721
Understanding near infrared spectroscopy and its application to skeletal muscle research
Barstow, T. J. (2019) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00166.2018 · Cited by 470
Cerebral blood flow and metabolism during exercise: implications for fatigue
Secher, N. H., Seifert, T., & Van Lieshout, J. J. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00853.2007 · Cited by 344
Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Metadata
- Authors
- Duncan, A., Meek, J. H., Clemence, M., Elwell, C. E., Tyszczuk, L., Cope, M., & Delpy, D.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1995-02-01
- Volume
- 40
- Issue
- 2
- Pages
- 295-304
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2114510322
- Cited by
- 649
- References
- 0
- FWCI
- 15.62
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optical pathlength measurements on adult head, calf and forearm and the head of the newborn infant using phase resolved optical spectroscopy. https://app.cochat.ai/papers/10.1088/0031-9155/40/2/007
- The paper
- Duncan, A., Meek, J. H., Clemence, M., Elwell, C. E., Tyszczuk, L., Cope, M., & Delpy, D. (1995). Optical pathlength measurements on adult head, calf and forearm and the head of the newborn infant using phase resolved optical spectroscopy. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/40/2/007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.