Optical pathlength measurements on adult head, calf and forearm and the head of the newborn infant using phase resolved optical spectroscopy
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
We have used an intensity modulated optical spectrometer, which measures the phase shift across tissue experienced by intensity modulated near-infrared light, to determine the absolute optical pathlength through tissue. The instrument is portable and takes only 5 s to record pathlength at four wavelengths (690 nm, 744 nm, 807 nm and 832 nm). The absolute pathlength divided by the known spacing between the light source and detector on the skin is the differential pathlength factor (DPF) which previous studies have shown is approximately constant for spacings greater than 2.5 cm. DPF results are presented for measurements on 100 adults and 35 newborn infants to determine the statistical variation on the DPF. All measurements were made at a frequency of 200 MHz with source-detector spacings of > 4 cm. Results at 807 nm show a DPF of 4.16(+/- 18.8%) for adult arm, 5.51(+/- 18%) for adult leg, 6.26(+/- 14.1%) for adult head and 4.99(+/- 9%) for the head of a newborn infant. A wavelength dependence was obtained for DPF on all tissues and a difference in DPF between male and female was observed for both the adult arm and leg. The results can be used to improve the quantitation of chromophore concentration changes in adults and newborn infants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Estimation of optical pathlength through tissue from direct time of flight measurement
Delpy, D. T., Cope, M., Zee, P. V. D., Arridge, S., Wray, S., & Wyatt, J. (1988) · Physics in Medicine and Biology · doi:10.1088/0031-9155/33/12/008 · Cited by 2,245
Self-citationCope, M., & Delpy, D. T. (1988) · Medical & Biological Engineering & Computing · doi:10.1007/bf02447083 · Cited by 1,065
Self-citationWyatt, J. S., Delpy, D. T., Cope, M., Wray, S., & Reynolds, E. O. R. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90467-8 · Cited by 876
Self-citationArridge, S. R., Cope, M., & Delpy, D. T. (1992) · Physics in Medicine and Biology · doi:10.1088/0031-9155/37/7/005 · Cited by 595
Self-citationRecovery from exercise-induced desaturation in the quadriceps muscles of elite competitive rowers
Chance, B., Dait, M. T., Zhang, C., Hamaoka, T., & Hagerman, F. (1992) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1992.262.3.c766 · Cited by 528
Refractive index of some mammalian tissues using a fiber optic cladding method
Bolin, F. P., Preuss, L. E., Taylor, R. C., & Ference, R. J. (1989) · Applied Optics · doi:10.1364/ao.28.002297 · Cited by 522
Quantitation of cerebral blood volume in human infants by near-infrared spectroscopy
Wyatt, J. S., Cope, M., Delpy, D. T., Richardson, C. E., Edwards, A. D., Wray, S., & Reynolds, E. O. (1990) · Journal of Applied Physiology · doi:10.1152/jappl.1990.68.3.1086 · Cited by 442
Self-citationvan der Zee, P., Cope, M., Arridge, S. R., Essenpreis, M., Potter, L. A., Edwards, A. D., Wyatt, J. S., McCormick, D. C., Roth, S. C., Reynolds, E. O. R., et al. (1992) · Advances in Experimental Medicine and Biology · doi:10.1007/978-1-4615-3404-4_17 · Cited by 427
Self-citationCOTSIDE MEASUREMENT OF CEREBRAL BLOOD FLOW IN ILL NEWBORN INFANTS BY NEAR INFRARED SPECTROSCOPY
Edwards, A. D., Richardson, C., Cope, M., Wyatt, J. S., Delpy, D. T., & Reynolds, E. O. R. (1988) · The Lancet · doi:10.1016/s0140-6736(88)92418-x · Cited by 370
Self-citation
Cited by
Ferrari, M., & Quaresima, V. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.03.049 · Cited by 2,274
“The instrument developed at the University College Londonwas utilized tomeasure the optical pathlength on newborn and adult head (Duncan et al., 1995); the instruments developed at Urbana-Champaign and Philadelphia were utilized also tomeasure for the first time O2Hb saturation on adult PFC (De Blasi et al.”
Scholkmann, F., Kleiser, S., Metz, A. J., Zimmermann, R., Mata Pavia, J., Wolf, U., & Wolf, M. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.004 · Cited by 2,002
Non-invasive optical spectroscopy and imaging of human brain function
Villringer, A., & Chance, B. (1997) · Trends in Neurosciences · doi:10.1016/s0166-2236(97)01132-6 · Cited by 1,618
Strangman, G., Culver, J. P., Thompson, J. H., & Boas, D. A. (2002) · NeuroImage · doi:10.1006/nimg.2002.1227 · Cited by 1,415
Diffuse optics for tissue monitoring and tomography
Durduran, T., Choe, R., Baker, W. B., & Yodh, A. G. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/7/076701 · Cited by 1,161
Lloyd-Fox, S., Blasi, A., & Elwell, C. E. (2010) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2009.07.008 · Cited by 865
Self-citationBoas, D. A., Dale, A. M., & Franceschini, M. A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.011 · Cited by 721
Progress of near-infrared spectroscopy and topography for brain and muscle clinical applications
Ferrari, M. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2804899 · Cited by 600
Strangman, G., Franceschini, M. A., & Boas, D. A. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00021-1 · Cited by 581
Best practices for fNIRS publications
Yücel, M. A., Lühmann, A. V., Scholkmann, F., Gervain, J., Dan, I., Ayaz, H., Boas, D., Cooper, R. J., Culver, J., Elwell, C. E., et al. (2021) · Neurophotonics · doi:10.1117/1.nph.8.1.012101 · Cited by 492
Self-citationOkada, E., Firbank, M., Schweiger, M., Arridge, S. R., Cope, M., & Delpy, D. T. (1997) · Applied Optics · doi:10.1364/ao.36.000021 · Cited by 477
Self-citationUnderstanding near infrared spectroscopy and its application to skeletal muscle research
Barstow, T. J. (2019) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00166.2018 · Cited by 470
Duncan, A., Meek, J. H., Clemence, M., Elwell, C. E., Fallon, P., Tyszczuk, L., Cope, M., & Delpy, D. T. (1996) · Pediatric Research · doi:10.1203/00006450-199605000-00025 · Cited by 469
Self-citationScholkmann, F., & Wolf, M. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.10.105004 · Cited by 450
Toronov, V., Webb, A., Choi, J. H., Wolf, M., Michalos, A., Gratton, E., & Hueber, D. (2001) · Medical Physics · doi:10.1118/1.1354627 · Cited by 380
DeLorey, D. S., Kowalchuk, J. M., & Paterson, D. H. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00956.2002 · Cited by 369
Cerebral blood flow and metabolism during exercise: implications for fatigue
Secher, N. H., Seifert, T., & Van Lieshout, J. J. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00853.2007 · Cited by 344
Non-invasive NIR spectroscopy of human brain function during exercise
Perrey, S. (2008) · Methods · doi:10.1016/j.ymeth.2008.04.005 · Cited by 346
Durduran, T., Yu, G., Burnett, M. G., Detre, J. A., Greenberg, J. H., Wang, J., Zhou, C., & Yodh, A. G. (2004) · Optics Letters · doi:10.1364/ol.29.001766 · Cited by 346
Illuminating the BOLD signal: combined fMRI–fNIRS studies
Steinbrink, J., Villringer, A., Kempf, F., Haux, D., Boden, S., & Obrig, H. (2006) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2005.12.034 · Cited by 334
Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Long-Term Enhancement of Brain Function and Cognition Using Cognitive Training and Brain Stimulation
Snowball, A., Tachtsidis, I., Popescu, T., Thompson, J., Delazer, M., Zamarian, L., Zhu, T., & Cohen Kadosh, R. (2013) · Current Biology · doi:10.1016/j.cub.2013.04.045 · Cited by 326
Near-infrared oximetry of the brain
Madsen, P. L., & Secher, N. H. (1999) · Progress in Neurobiology · doi:10.1016/s0301-0082(98)00093-8 · Cited by 315
Ding, H., Lu, J. Q., Wooden, W. A., Kragel, P. J., & Hu, X.-H. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/6/008 · Cited by 291
Wavelet minimum description length detrending for near-infrared spectroscopy
Jang, K. E., Tak, S., Jung, J., Jang, J., Jeong, Y., & Ye, J. C. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3127204 · Cited by 279
A flexible organic reflectance oximeter array
Khan, Y., Han, D., Pierre, A., Ting, J., Wang, X., Lochner, C. M., Bovo, G., Yaacobi-Gross, N., Newsome, C., Wilson, R., et al. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1813053115 · Cited by 278
“5, the molar extinction coefficients and DPF (λ) can be obtained from the literature (1, 24).”
MethodResultJasdzewski, G., Strangman, G., Wagner, J., Kwong, K. K., Poldrack, R. A., & Boas, D. A. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00311-2 · Cited by 277
Cerebral Near-Infrared Spectroscopy in Adults: A Work in Progress
Ghosh, A., Elwell, C., & Smith, M. (2012) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31826dd6a6 · Cited by 277
Self-citationEffects of acute hypoxia on cerebral and muscle oxygenation during incremental exercise
Subudhi, A. W., Dimmen, A. C., & Roach, R. C. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01460.2006 · Cited by 271
Schroeter, M. L., Zysset, S., Kupka, T., Kruggel, F., & von Cramon, D. Y. (2002) · Human Brain Mapping · doi:10.1002/hbm.10052 · Cited by 259
Determining changes in NIR absorption using a layered model of the human head
Steinbrink, J., Wabnitz, H., Obrig, H., Villringer, A., & Rinneberg, H. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/320 · Cited by 259
Near-infrared spectroscopy for medical applications: Current status and future perspectives
Sakudo, A. (2016) · Clinica Chimica Acta · doi:10.1016/j.cca.2016.02.009 · Cited by 248
Near-Infrared spectroscopy: Theory and applications
Wahr, J. A., Tremper, K. K., Samra, S., & Delpy, D. T. (1996) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/s1053-0770(96)80107-8 · Cited by 227
Self-citationSocial perception in infancy: A near infrared spectroscopy study
Lloyd-Fox, S., Blasi, A., Volein, A., Everdell, N., Elwell, C. E., & Johnson, M. H. (2009) · Child Development · doi:10.1111/j.1467-8624.2009.01312.x · Cited by 217
“, 1988) and assuming a differential pathlength factor for infants (5.13; Duncan et al., 1995).”
BackgroundMethodInfluentialSelf-citationYamada, T., Umeyama, S., & Matsuda, K. (2012) · PLoS ONE · doi:10.1371/journal.pone.0050271 · Cited by 218
“Because individual data are differently scaled owing to the difference in the optical path length of subjects or optode positions [57,58], we cannot calculate a precise average over subjects unless the optical path lengths are given.”
BackgroundFunane, T., Kiguchi, M., Atsumori, H., Sato, H., Kubota, K., & Koizumi, H. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3602853 · Cited by 198
Kaiser, V., Bauernfeind, G., Kreilinger, A., Kaufmann, T., Kübler, A., Neuper, C., & Müller-Putz, G. R. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.097 · Cited by 192
Myers, D. E., Anderson, L. D., Seifert, R. P., Ortner, J. P., Cooper, C. E., Beilman, G. J., & Mowlem, J. D. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1925250 · Cited by 187
Di Lorenzo, R., Pirazzoli, L., Blasi, A., Bulgarelli, C., Hakuno, Y., Minagawa, Y., & Brigadoi, S. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.06.056 · Cited by 181
“The fNIRS data was acquired with the NTS diffuse optical imaging half-system (NTS2 – Gowerlabs Ltd UK; Everdell et al., 2005), consisting of eight dual-wavelength sources (780 nm, 850 nm) and eight detectors, which form 22 source-detector channels at a separation of 2 cm (see Fig.”
MethodToronov, V., Franceschini, M. A., Filiaci, M., Fantini, S., Wolf, M., Michalos, A., & Gratton, E. (2000) · Medical Physics · doi:10.1118/1.598943 · Cited by 169
Thavasothy, M., Broadhead, M., Elwell, C., Peters, M., & Smith, M. (2002) · Anaesthesia · doi:10.1046/j.1365-2044.2002.02826.x · Cited by 165
Self-citationHomma, S., Fukunaga, T., & Kagaya, A. (1996) · Journal of Biomedical Optics · doi:10.1117/12.252417 · Cited by 123
Cortical responses before 6 months of life associate with later autism
Lloyd‐Fox, S., Blasi, A., Pasco, G., Gliga, T., Jones, E. J. H., Murphy, D. G. M., Elwell, C. E., Charman, T., Johnson, M. H., & the BASIS Team (2018) · European Journal of Neuroscience · doi:10.1111/ejn.13757 · Cited by 120
Self-citationShannon, O. M., Duckworth, L., Barlow, M. J., Deighton, K., Matu, J., Williams, E. L., Woods, D., Xie, L., Stephan, B. C. M., Siervo, M., et al. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2017.00401 · Cited by 76
Louvaris, Z., Zakynthinos, S., Aliverti, A., Habazettl, H., Vasilopoulou, M., Andrianopoulos, V., Wagner, H., Wagner, P., & Vogiatzis, I. (2012) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00481.2012 · Cited by 45
Bourdillon, N., Fan, J.-L., Uva, B., Müller, H., Meyer, P., & Kayser, B. (2015) · Frontiers in Physiology · doi:10.3389/fphys.2015.00288 · Cited by 44
“…www.frontiersin.org 3 October 2015 | Volume 6 | Article 288 (O2Hb and HHb, respectively) obtained with spatially resolved, continuous wave near infrared spectroscopy (NIRS, Artinis Oxymon, MKIII, Zetten, The Netherlands) using a sourcedetector spacing of 3.8 cm and DPF of 4.0 (Duncan et al., 1995).”
MethodInfluentialMuscle oxygenation by near-infrared-based tissue oximeters
Quaresima, V., & Ferrari, M. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00215.2009 · Cited by 36
Rissanen, A.-P. E., Tikkanen, H. O., Koponen, A. S., Aho, J. M., Hägglund, H., Lindholm, H., & Peltonen, J. E. (2012) · Frontiers in Physiology · doi:10.3389/fphys.2012.00265 · Cited by 25
“The values used for the differential pathlength factor (DPF) were 5.51 for the leg, and 4.16 for the arm (van der Zee et al., 1992; Duncan et al., 1995).”
MethodInfluentialCarbon monoxide exposure during exercise performance: muscle and cerebral oxygenation
Keramidas, M. E., Kounalakis, S. N., Eiken, O., & Mekjavic, I. B. (2012) · Acta Physiologica · doi:10.1111/j.1748-1716.2011.02363.x · Cited by 19
Muscle deoxygenation of upper-limb muscles during progressive arm-cranking exercise
Lusina, S.-J. C., Warburton, D. E. R., Hatfield, N. G., & Sheel, A. W. (2008) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/h07-156 · Cited by 18
Metadata
- Authors
- Duncan, A., Meek, J. H., Clemence, M., Elwell, C. E., Tyszczuk, L., Cope, M., & Delpy, D.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1995-02-01
- Volume
- 40
- Issue
- 2
- Pages
- 295-304
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2114510322
- Cited by
- 649
- References
- 21
- FWCI
- 15.62
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.