Dose-rate effects in targeted radiotherapy
Open accessThe DOI matches its Crossref record.
Abstract
The physical dose delivered in radio-immunotherapy (RIT) may not, by itself, be a reliable indicator of the likely effectiveness of the treatment. Radiobiological considerations, in particular those relating to the dose-rate, are also very relevant. Dose-rate effects are important in conventional radiotherapy because of their ability to produce differential sparing effects between normal and malignant tissue. With targeted radiotherapy, in which dose-rates are likely to vary both spatially and temporally, the instantaneous dose-rate is additionally relevant since it determines whether or not any on-going clonogenic tumour re-population can be controlled. Therefore, for RIT in particular, there are two separate facets to the dose-rate effect, one concerned with the relative ability of different tissues to recover from radiation damage, the other concerned with the absolute ability to control concurrent tumour re-growth. In this article these two aspects are examined in terms of the linear-quadratic model and the implications assessed. Other radiobiological issues, such as re-oxygenation and cell cycle re-distribution are not discussed here.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bolch, W. E., Eckerman, K. F., Sgouros, G., & Thomas, S. R. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.056036 · Cited by 913
Violet, J., Jackson, P., Ferdinandus, J., Sandhu, S., Akhurst, T., Iravani, A., Kong, G., Kumar, A. R., Thang, S. P., Eu, P., et al. (2019) · Journal of Nuclear Medicine · doi:10.2967/jnumed.118.219352 · Cited by 504
Strigari, L., Sciuto, R., Rea, S., Carpanese, L., Pizzi, G., Soriani, A., Iaccarino, G., Benassi, M., Ettorre, G. M., & Maini, C. L. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.075861 · Cited by 239
Chiesa, C., Mira, M., Maccauro, M., Spreafico, C., Romito, R., Morosi, C., Camerini, T., Carrara, M., Pellizzari, S., Negri, A., et al. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-015-3068-8 · Cited by 164
“The dosimetric interpretation of nuclear medicine radiotherapy outcome requires the introduction of two factors that affect the radiobiological implications: the non-uniformity of absorbed dose deposition, accounted for by a radiobiological variable named EUD, and the dose-rate effect, accounted for by the BED [22, 23…”
Cremonesi, M., Ferrari, M. E., Bodei, L., Chiesa, C., Sarnelli, A., Garibaldi, C., Pacilio, M., Strigari, L., Summers, P. E., Orecchia, R., et al. (2018) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-018-4044-x · Cited by 141
“93, and introduced the description of dose-rate effects by the linear quadratic model, as used in EBRTand brachytherapy, to radionuclide therapy [32, 52]:”
Metadata
- Authors
- Dale, R. G.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1996-10-01
- Volume
- 41
- Issue
- 10
- Pages
- 1871-1884
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2014544986
- Cited by
- 166
- References
- 0
- FWCI
- 1.22
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dose-rate effects in targeted radiotherapy. https://app.cochat.ai/papers/10.1088/0031-9155/41/10/001
- The paper
- Dale, R. G. (1996). Dose-rate effects in targeted radiotherapy. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/41/10/001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.