The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Simultaneous PET and MR imaging
Open accessAbstract
We have developed a prototype PET detector which is compatible with a clinical MRI system to provide simultaneous PET and MR imaging. This single-slice PET system consists of 48 2 x 2 x 10 mm3 LSO crystals in a 38 mm diameter ring configuration that can be placed inside the receiver coil of the MRI system, coupled to three multi-channel photomultipliers housed outside the main magnetic field via 4 m long and 2 mm diameter optical fibres. The PET system exhibits 2 mm spatial resolution, 41% energy resolution at 511 keV and 20 ns timing resolution. Simultaneous PET and MR phantom images were successfully acquired.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cerium-doped lutetium oxyorthosilicate: a fast, efficient new scintillator
Melcher, C. L., & Schweitzer, J. S. (1992) · IEEE Transactions on Nuclear Science · doi:10.1109/23.159655 · Cited by 846
Simple charge division readouts for imaging scintillator arrays using a multi-channel PMT
Siegel, S. B., Silverman, R. W., Shao, Y., & Cherry, S. R. (1996) · IEEE Transactions on Nuclear Science · doi:10.1109/23.507162 · Cited by 312
Self-citationQuantitative Comparisons of Image Registration Techniques Based on High-Resolution MRI of the Brain
Strother, S. C., Anderson, J. R., Xu, X., Liow, J., Bonar, D. C., & Rottenberg, D. A. (1994) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199411000-00021 · Cited by 121
Cited by
Simultaneous PET-MRI: a new approach for functional and morphological imaging
Judenhofer, M. S., Wehrl, H. F., Newport, D. F., Catana, C., Siegel, S. B., Becker, M., Thielscher, A., Kneilling, M., Lichy, M. P., Eichner, M., et al. (2008) · Nature Medicine · doi:10.1038/nm1700 · Cited by 981
Self-citationLee, H.-Y., Li, Z., Chen, K., Hsu, A. R., Xu, C., Xie, J., Sun, S., & Chen, X. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.051243 · Cited by 557
‘Two is better than one’—probes for dual-modality molecular imaging
Jennings, L. E., & Long, N. J. (2009) · Chemical Communications · doi:10.1039/b821903f · Cited by 438
PET/MRI: Paving the Way for the Next Generation of Clinical Multimodality Imaging Applications
Pichler, B. J., Kolb, A., Nägele, T., & Schlemmer, H.-P. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.061853 · Cited by 418
Design and performance evaluation of a whole-body Ingenuity TF PET–MRI system
Zaidi, H., Ojha, N., Morich, M., Griesmer, J., Hu, Z., Maniawski, P., Ratib, O., Izquierdo-Garcia, D., Fayad, Z. A., & Shao, L. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/10/013 · Cited by 402
Metadata
- Authors
- Shao, Y., Cherry, S. R., Farahani, K., Meadors, K., Siegel, S., Silverman, R. W., & Marsden, P. K.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1997-10-01
- Volume
- 42
- Issue
- 10
- Pages
- 1965-1970
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2044764673
- Cited by
- 374
- References
- 3
- FWCI
- 4.16
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Simultaneous PET and MR imaging. https://app.cochat.ai/papers/10.1088/0031-9155/42/10/010
- The paper
- Shao, Y., Cherry, S. R., Farahani, K., Meadors, K., Siegel, S., Silverman, R. W., & Marsden, P. K. (1997). Simultaneous PET and MR imaging. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/42/10/010
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.