PET/MRI: Paving the Way for the Next Generation of Clinical Multimodality Imaging Applications
Open accessAbstract
Multimodality imaging and, more specifically, the combination of PET and CT has matured into an important diagnostic tool. During the same period, concepts for PET scanners integrated into an MR tomograph have emerged. The excellent soft-tissue contrast of MRI and the multifunctional imaging options it offers, such as spectroscopy, functional MRI, and arterial spin labeling, complement the molecular information of PET. The development of a fully integrated PET/MRI system is technologically challenging. It requires not only significant modifications of the PET detector to make it compact and insensitive to magnetic fields but also a major redesign of the MRI hardware.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Combining radiopharmaceutical techniques with other diagnostic methods, such as PET and MRI, provides complementary anatomical and functional information, improving diagnostic accuracy in neurological disorders.
“The integration of radiopharmaceutical techniques with other diagnostic methods, such as the combination of PET and MRI, provides complementary anatomical and functional information, improving diagnostic accuracy in neurological disorders [44].”
From Radiopharmaceuticals: navigating the frontier of precision medicine and therapeutic innovation (2024) · cites this paper as [44]
The Abstract says MRI’s soft-tissue contrast complements PET’s molecular information. In “Clinical Potential of PET/MRI” (page unavailable), the paper describes a brain-tumor case in which combining the images revealed disease extent that neither modality showed fully alone. It presents broader benefits for neurological disorders as expectations, rather than establishing a general improvement in diagnostic accuracy. (LLM, conf=0.85)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
A combined PET/CT scanner for clinical oncology.
Beyer, T., Townsend, D. W., Brun, T., Kinahan, P. E., Charron, M., Roddy, R., Jerin, J., Young, J., Byars, L. G., & Nutt, R. (2000) · PubMed · Cited by 1,655 · see citing works
Simultaneous PET-MRI: a new approach for functional and morphological imaging
Judenhofer, M. S., Wehrl, H. F., Newport, D. F., Catana, C., Siegel, S. B., Becker, M., Thielscher, A., Kneilling, M., Lichy, M. P., Eichner, M., et al. (2008) · Nature Medicine · doi:10.1038/nm1700 · Cited by 983 · see citing works
Self-citationMartínez-Möller, A., Souvatzoglou, M., Delso, G., Bundschuh, R. A., Chefd’hotel, C., Ziegler, S. I., Navab, N., Schwaiger, M., & Nekolla, S. G. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.054726 · Cited by 712 · see citing works
Benefit of Time-of-Flight in PET: Experimental and Clinical Results
Karp, J. S., Surti, S., Daube-Witherspoon, M. E., & Muehllehner, G. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.044834 · Cited by 585 · see citing works
Whole-Body Dual-Modality PET/CT and Whole-Body MRI for Tumor Staging in Oncology
Antoch, G. (2003) · JAMA · doi:10.1001/jama.290.24.3199 · Cited by 551 · see citing works
Whole-Body PET/CT Scanning: Estimation of Radiation Dose and Cancer Risk
Huang, B., Law, M. W.-M., & Khong, P. (2009) · Radiology · doi:10.1148/radiol.2511081300 · Cited by 523 · see citing works
Hofmann, M., Steinke, F., Scheel, V., Charpiat, G., Farquhar, J. D. R., Aschoff, P., Brady, M., Schölkopf, B., & Pichler, B. J. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.049353 · Cited by 495 · see citing works
Self-citationSimultaneous MR/PET Imaging of the Human Brain: Feasibility Study
Schlemmer, H.-P., Pichler, B. J., Schmand, M. J., Burbar, Z., Michel, C. J., Ladebeck, R., Jattke, K., Townsend, D. W., Nahmias, C., Jacob, P. K., et al. (2008) · Radiology · doi:10.1148/radiol.2483071927 · Cited by 473 · see citing works
Self-citationRadiation exposure of patients undergoing whole-body dual-modality 18F-FDG PET/CT examinations.
Brix, G., Lechel, U., Glatting, G., Ziegler, S. I., Münzing, W., Müller, S. P., & Beyer, T. (2005) · PubMed · Cited by 458 · see citing works
Simultaneous PET and MR imaging
Shao, Y., Cherry, S. R., Farahani, K., et al. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/10/010 · Cited by 380 · see citing works
Towards quantitative PET/MRI: a review of MR-based attenuation correction techniques
Hofmann, M., Pichler, B. J., Schölkopf, B., & Beyer, T. (2008) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-008-1007-7 · Cited by 343 · see citing works
Self-citationDual-Modality Imaging: Combining Anatomy and Function
Townsend, D. W. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.051276 · Cited by 279 · see citing works
A combined PET/CT scanner: the path to true image fusion
Townsend, D. W., & Beyer, T. (2002) · British Journal of Radiology · doi:10.1259/bjr.75.suppl_9.750024 · Cited by 241 · see citing works
Latest Advances in Molecular Imaging Instrumentation
Pichler, B. J., Wehrl, H. F., & Judenhofer, M. S. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.045880 · Cited by 224 · see citing works
Self-citationPfannenberg, C., Aschoff, P., Schanz, S., et al. (2007) · European Journal of Cancer · doi:10.1016/j.ejca.2006.11.014 · Cited by 191 · see citing works
Schmidt, G. P., Baur‐Melnyk, A., Herzog, P., et al. (2005) · Investigative Radiology · doi:10.1097/01.rli.0000185878.61270.b0 · Cited by 158 · see citing works
Whole-body MRI using a rolling table platform for the detection of bone metastases
Lauenstein, T. C., Freudenberg, L. S., Goehde, S. C., et al. (2002) · European Radiology · doi:10.1007/s00330-002-1344-z · Cited by 150 · see citing works
The potential of PET/MR for brain imaging
Heiss, W. (2008) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-008-0962-3 · Cited by 139 · see citing works
PET and MRI in cardiac imaging: from validation studies to integrated applications
Nekolla, S. G., Martínez-Möller, A., & Saraste, A. (2008) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-008-0980-1 · Cited by 127 · see citing works
A look ahead: PET/MR versus PET/CT
von Schulthess, G. K., & Schlemmer, H.-P. (2008) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-008-0940-9 · Cited by 125 · see citing works
Self-citationPotential and feasibility of parallel MRI at high field
Wiesinger, F., de Moortele, P. V., Adriany, G., et al. (2006) · NMR in Biomedicine · doi:10.1002/nbm.1050 · Cited by 125 · see citing works
Fast Whole-Body Assessment of Metastatic Disease Using a Novel Magnetic Resonance Imaging System
Schlemmer, H. P., Sch??fer, J., Pfannenberg, C., Radny, P., Korchidi, S., M??ller-Horvat, C., N??gele, T., Tomaschko, K., Fenchel, M. C., & Claussen, C. D. (2005) · Investigative Radiology · doi:10.1097/01.rli.0000149250.37033.7c · Cited by 112 · see citing works
Self-citationMultimodality imaging: an update on PET/CT technology
Mawlawi, O. R., & Townsend, D. W. (2008) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-008-1016-6 · Cited by 110 · see citing works
Müller-Horvat, C., Radny, P., Eigentler, T., et al. (2005) · European Journal of Cancer · doi:10.1016/j.ejca.2005.10.008 · Cited by 100 · see citing works
Real-Time Iterative Monitoring of Radiofrequency Ablation Tumor Therapy with 15O-Water PET Imaging
Bao, A., Goins, B., Dodd, G. D., et al. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.052886 · Cited by 20 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Hierarchical Feature Representation and Multimodal Fusion with Deep Learning for AD/MCI Diagnosis
Suk, H.-I., Lee, S.-W., & Shen, D. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.06.077 · Cited by 968 · see citing works
NK cell-based immunotherapy for malignant diseases
Cheng, M., Chen, Y., Xiao, W., Sun, R., & Tian, Z. (2013) · Cellular & Molecular Immunology · doi:10.1038/cmi.2013.10 · Cited by 631 · see citing works
Radiopharmaceuticals: navigating the frontier of precision medicine and therapeutic innovation
Dhoundiyal, S., Srivastava, S., Kumar, S., Singh, G., Ashique, S., Pal, R., Mishra, N., & Taghizadeh-Hesary, F. (2024) · European Journal of Medical Research · doi:10.1186/s40001-023-01627-0 · Cited by 144 · see citing works
“The integration of radiopharmaceutical techniques with other diagnostic methods, such as the combination of PET and MRI, provides complementary anatomical and functional information, improving diagnostic accuracy in neurological disorders [44].”
MethodRolle, A.-M., Hasenberg, M., Thornton, C. R., Solouk-Saran, D., Männ, L., Weski, J., Maurer, A., Fischer, E., Spycher, P. R., Schibli, R., et al. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1518836113 · Cited by 134 · see citing works
Self-citationWang, L., Li, N., Wang, W., Mei, A., Shao, J., Wang, W., & Dong, X. (2024) · ACS Nano · doi:10.1021/acsnano.3c12316 · Cited by 127 · see citing works
PET-MR and SPECT-MR multimodality probes: Development and challenges
Yang, C.-T., Ghosh, K. K., Padmanabhan, P., Langer, O., Liu, J., Eng, D. N. C., Halldin, C., & Gulyás, B. (2018) · Theranostics · doi:10.7150/thno.26610 · Cited by 101 · see citing works
Davies, G., Rolle, A.-M., Maurer, A., Spycher, P. R., Schillinger, C., Solouk-Saran, D., Hasenberg, M., Weski, J., Fonslet, J., Dubois, A., et al. (2017) · Theranostics · doi:10.7150/thno.20919 · Cited by 63 · see citing works
Self-citation
- Authors
- Pichler, B. J., Kolb, A., Nägele, T., & Schlemmer, H.-P.
- Affiliations
- University of Tübingen (DE)
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2010-02-11
- Volume
- 51
- Issue
- 3
- Pages
- 333-336
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2015447436
- Cited by
- 418
- References
- 25
- Citations by year
- 2026: 3 · 2025: 5 · 2024: 10 · 2023: 13 · 2022: 16 · 2021: 12 · 2020: 18 · 2019: 18 · 2018: 26 · 2017: 32 · 2016: 34 · 2015: 42 · 2014: 47 · 2013: 55 · 2012: 39
- FWCI
- 36.91
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Journal of Nuclear Medicine (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Deutsche Forschungsgemeinschaft (PI771, SFB 773)
- National Institutes of Health
- National Institute of Biomedical Imaging and Bioengineering (R21EB004483)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
- Keywords
- PET/MRI, multimodal imaging, PET/CT, PET detector design, magnetic field insensitivity, soft tissue contrast, functional MRI, arterial spin labeling, MRI spectroscopy, molecular imaging
- MeSH terms
- Adult, Aged, Brain Neoplasms, Female, Humans, Liver Neoplasms, Magnetic Resonance Imaging, Meningioma, Middle Aged, Ovarian Neoplasms, Positron-Emission Tomography, Whole Body Imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review