The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
FDTD calculations of the whole-body averaged SAR in an anatomically realistic voxel model of the human body from 1 MHz to 1 GHz
Open accessAbstract
This paper presents finite-difference time-domain (FDTD) calculations of the whole-body averaged SAR in an anatomically realistic voxel model of the human body. This model, NORMAN, consists of approximately 9 million voxels, of 2 mm dimension in the adult phantom, segmented into 37 tissue types. SAR values are presented for an adult phantom and for scaled 10, 5 and 1 year old models, grounded and isolated in air from 1 MHz to 1 GHz for plane wave exposure. External electric field values corresponding to a whole-body averaged SAR of 0.4 W kg-1 are also presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mur, G. (1981) · IEEE Transactions on Electromagnetic Compatibility · doi:10.1109/temc.1981.303970 · Cited by 2,565
Cited by
De Wilde, J. P., Rivers, A. W., & Price, D. L. (2005) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2004.08.010 · Cited by 351
Dimbylow, P. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/6/002 · Cited by 276
Self-citation
Metadata
- Authors
- Dimbylow, P. J.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1997-03-01
- Volume
- 42
- Issue
- 3
- Pages
- 479-490
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2015926885
- Cited by
- 284
- References
- 1
- FWCI
- 4.72
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: FDTD calculations of the whole-body averaged SAR in an anatomically realistic voxel model of the human body from 1 MHz to 1 GHz. https://app.cochat.ai/papers/10.1088/0031-9155/42/3/003
- The paper
- Dimbylow, P. J. (1997). FDTD calculations of the whole-body averaged SAR in an anatomically realistic voxel model of the human body from 1 MHz to 1 GHz. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/42/3/003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.