Comparison of cardiac-induced endogenous fields and power frequency induced exogenous fields in an anatomical model of the human body
Open accessAbstract
Time-domain potentials measured at 64 points on the surface of a large canine heart, considered comparable with those of a human heart, were used to calculate the electric fields and current densities within various organs of the human body. A heterogeneous volume conductor model of an adult male with a resolution of approximately 6 mm3 and 30 segmented tissue types was used along with the admittance method and successive over-relaxation to calculate the voltage distribution throughout the torso and head as a function of time. From this time-domain voltage description, values of [E(t)] and [J(t)] were obtained, allowing for maximum values to be found within the given tissues of interest. Frequency analysis was then used to solve for [E(f)] and [J(f)] in the various organs, so that average, minimum and maximum values within specific bandwidths (0-40, 40-70 and 70-100 Hz) could be analysed. A comparison was made between the computed results and measured data from both EKG waveforms and isopotential surface maps for validation, with good agreement in both amplitude and shape between the computed and measured results. These computed endogenous fields were then compared with exogenous fields induced in the body from a 60 Hz high-voltage power line and a 60 Hz uniform magnetic field of 1 mT directed from the front to the back of the body. The high-voltage power line EMFs and 1 mT magnetic field were used as 'bench' marks for comparison with several safety guidelines for power frequency (50/60 Hz) EMF exposures. The endogenous electric fields and current densities in most of the tissues (except for organs in close proximity to the heart, for example lungs, liver, etc) in the frequency band 40-70 Hz were found to be considerably smaller, between 5% and 10%, than those induced in the human body by the electric and magnetic fields generated by the 60 Hz sources described above.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Field strength is ~1 nT near the myocardium, ~0.1 nT at the body surface, and 10–100 pT a few centimeters above the chest—much weaker than the Earth’s field but far stronger than cortical sources [Figure 1] [20,21,22,23,25,26,27].”
From The Heart’s Electromagnetic Field in Emotions, Empathy and Human Connection: Biosensor-Derived Insights into Heart–Brain Axis Mechanisms and a Basis for Novel BioMagnetoTherapies (2026) · cites this paper as [22]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Its EMF is generated throughout the cardiac cycle and is mainly attributed to transmembrane Na+, K+, and Ca2+ fluxes during depolarization and repolarization, generating time-varying magnetic signals, detectable by sensitive biosensors, in line with Maxwell’s equations [Figure 1] [22,23,24,25,26].”
From The Heart’s Electromagnetic Field in Emotions, Empathy and Human Connection: Biosensor-Derived Insights into Heart–Brain Axis Mechanisms and a Basis for Novel BioMagnetoTherapies (2026) · cites this paper as [22]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Lung tissue, due to its high electrical resistivity (~2000 Ω·cm) compared to ventricular muscle (~400 Ω·cm) and blood (~160 Ω·cm), impedes radial EMFs and favors tangential currents [22,27].”
From The Heart’s Electromagnetic Field in Emotions, Empathy and Human Connection: Biosensor-Derived Insights into Heart–Brain Axis Mechanisms and a Basis for Novel BioMagnetoTherapies (2026) · cites this paper as [22]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“The heart is the body’s largest bioelectrical source, producing stronger surface potentials than nerves or skeletal muscle [20,21,22].”
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Field strength is ~1 nT near the myocardium, ~0.1 nT at the body surface, and 10–100 pT a few centimeters above the chest—much weaker than the Earth’s field but far stronger than cortical sources [Figure 1] [20,21,22,23,25,26,27].”
From The Heart’s Electromagnetic Field in Emotions, Empathy and Human Connection: Biosensor-Derived Insights into Heart–Brain Axis Mechanisms and a Basis for Novel BioMagnetoTherapies (2026) · cites this paper as [22]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Report of the task group on reference man
(1979) · Annals of the ICRP · doi:10.1016/0146-6453(79)90123-4 · Cited by 1,726
Geddes, L. A., & Baker, L. E. (1967) · Medical & Biological Engineering & Computing · doi:10.1007/bf02474537 · Cited by 1,612
Dielectric properties of tissues and biological materials: a critical review.
Foster, K. R., & Schwan, H. P. (1989) · PubMed · Cited by 1,186
Herbertz, J. (1998) · PubMed · Cited by 597
Resistivity of Body Tissues at Low Frequencies
Rush, S., Abildskov, J. A., & McFee, R. (1963) · Circulation Research · doi:10.1161/01.res.12.1.40 · Cited by 449
Clinical Electrocardiography: A Simplified Approach
Goldberger, A. L. (2006) · Elsevier eBooks · doi:10.1016/b0-323-04038-1/x5001-x · Cited by 274
Impedance of Skeletal Muscle from 1 Hz to 1 MHz
Zheng, E., Shao, S.-Y., & Webster, J. G. (1984) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1984.325417 · Cited by 140
Endogenous ionic currents and DC electric fields in multicellular animal tissues
Nuccitelli, R. (1992) · Bioelectromagnetics · doi:10.1002/bem.2250130714 · Cited by 129
A Spectral Analysis of the Normal Resting Electrocardiogram
Golden, D. P., Wolthuis, R. A., & Hoffler, G. W. (1973) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1973.324231 · Cited by 123
Research works printed but not linked: 3
- American Conference of Governmental Industrial Hygienists (ACGIH), 1997
- Foster K R, 1989, Crit. Rev. Biomed. Eng., 17, 25
- International Commission on Non-Ionizing Radiation Protection (ICNIRP), 1998, Health Phys., 74, 494
Cited by
Cardiac torsion and electromagnetic fields: The cardiac bioinformation hypothesis
Burleson, K. O., & Schwartz, G. E. (2005) · Medical Hypotheses · doi:10.1016/j.mehy.2004.12.023 · Cited by 16
Palantzas, A., & Anagnostouli, M. (2026) · Sensors · doi:10.3390/s26051738 · Cited by 1
Metadata
- Authors
- Hart, R. A., & Gandhi, O. P.
- Affiliations
- University of Utah (US)
- ORCID
- Gandhi, Om P
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1998-10-01
- Volume
- 43
- Issue
- 10
- Pages
- 3083-3099
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2045662093
- Cited by
- 34
- References
- 23
- Citations by year
- 2026: 1 · 2024: 2 · 2022: 2 · 2017: 2 · 2016: 1
- FWCI
- 2.94
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Physics in Medicine and Biology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation (9215274)
- U.S. Department of Energy
- Oak Ridge National Laboratory
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Electromagnetic Fields and Biological Effects
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electromagnetic Simulation and Numerical Methods
- Keywords
- cardiac electric field, endogenous electric fields, power frequency electromagnetic fields, 60 Hz magnetic fields, current density distribution, human body model, volume conductor model, ECG validation
- MeSH terms
- Adult, Animals, Brain, Dogs, Electric Conductivity, Electrocardiography, Electromagnetic Fields, Heart, Humans, Liver, Male, Models, Anatomic, Guidelines as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review