Cited by 34Electromagnetic Fields and Biological EffectsECG Monitoring and AnalysisElectromagnetic Simulation and Numerical Methods

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

Comparison of cardiac-induced endogenous fields and power frequency induced exogenous fields in an anatomical model of the human body

Open access
Hart, Rodney A, Gandhi, Om P·1998·Physics in Medicine and Biology

Abstract

Time-domain potentials measured at 64 points on the surface of a large canine heart, considered comparable with those of a human heart, were used to calculate the electric fields and current densities within various organs of the human body. A heterogeneous volume conductor model of an adult male with a resolution of approximately 6 mm3 and 30 segmented tissue types was used along with the admittance method and successive over-relaxation to calculate the voltage distribution throughout the torso and head as a function of time. From this time-domain voltage description, values of [E(t)] and [J(t)] were obtained, allowing for maximum values to be found within the given tissues of interest. Frequency analysis was then used to solve for [E(f)] and [J(f)] in the various organs, so that average, minimum and maximum values within specific bandwidths (0-40, 40-70 and 70-100 Hz) could be analysed. A comparison was made between the computed results and measured data from both EKG waveforms and isopotential surface maps for validation, with good agreement in both amplitude and shape between the computed and measured results. These computed endogenous fields were then compared with exogenous fields induced in the body from a 60 Hz high-voltage power line and a 60 Hz uniform magnetic field of 1 mT directed from the front to the back of the body. The high-voltage power line EMFs and 1 mT magnetic field were used as 'bench' marks for comparison with several safety guidelines for power frequency (50/60 Hz) EMF exposures. The endogenous electric fields and current densities in most of the tissues (except for organs in close proximity to the heart, for example lungs, liver, etc) in the frequency band 40-70 Hz were found to be considerably smaller, between 5% and 10%, than those induced in the human body by the electric and magnetic fields generated by the 60 Hz sources described above.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0031-9155/43/10/027

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 3

  1. American Conference of Governmental Industrial Hygienists (ACGIH), 1997
  2. Foster K R, 1989, Crit. Rev. Biomed. Eng., 17, 25
  3. International Commission on Non-Ionizing Radiation Protection (ICNIRP), 1998, Health Phys., 74, 494

Metadata

Authors
Hart, R. A., & Gandhi, O. P.
Affiliations
University of Utah (US)
Venue
Physics in Medicine and Biology
Published
1998-10-01
Volume
43
Issue
10
Pages
3083-3099
ISSN
  • 0031-9155 (ISSN-L)
  • 1361-6560
OpenAlex
W2045662093
Cited by
34
References
23
Citations by year
2026: 1 · 2024: 2 · 2022: 2 · 2017: 2 · 2016: 1
FWCI
2.94
Type
journal article
Language
en
Open access
Locations
  • Physics in Medicine and Biology (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Science Foundation (9215274)
  • U.S. Department of Energy
  • Oak Ridge National Laboratory
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Electromagnetic Fields and Biological Effects
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electromagnetic Simulation and Numerical Methods
Keywords
cardiac electric field, endogenous electric fields, power frequency electromagnetic fields, 60 Hz magnetic fields, current density distribution, human body model, volume conductor model, ECG validation
MeSH terms
Adult, Animals, Brain, Dogs, Electric Conductivity, Electrocardiography, Electromagnetic Fields, Heart, Humans, Liver, Male, Models, Anatomic, Guidelines as Topic

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review