Reducing the influence of the partial volume effect on SPECT activity quantitation with 3D modelling of spatial resolution in iterative reconstruction
Open accessAbstract
Quantitative parameters such as the maximum and total counts in a volume are influenced by the partial volume effect. The magnitude of this effect varies with the non-stationary and anisotropic spatial resolution in SPECT slices. The objective of this investigation was to determine whether iterative reconstruction which includes modelling of the three-dimensional (3D) spatial resolution of SPECT imaging can reduce the impact of the partial volume effect on the quantitation of activity compared with filtered backprojection (FBP) techniques which include low-pass, and linear restoration filtering using the frequency distance relationship (FDR). The iterative reconstruction algorithms investigated were maximum-likelihood expectation-maximization (MLEM), MLEM with ordered subset acceleration (ML-OS), and MLEM with acceleration by the rescaled-block-iterative technique (ML-RBI). The SIMIND Monte Carlo code was used to simulate small hot spherical objects in an elliptical cylinder with and without uniform background activity as imaged by a low-energy ultra-high-resolution (LEUHR) collimator. Centre count ratios (CCRs) and total count ratios (TCRs) were determined as the observed counts over true counts. CCRs were unstable while TCRs had a bias of approximately 10% for all iterative techniques. The variance in the TCRs for ML-OS and ML-RBI was clearly elevated over that of MLEM, with ML-RBI having the smaller elevation. TCRs obtained with FDR-Wiener filtering had a larger bias (approximately 30%) than any of the iterative reconstruction methods but near stationarity is also reached. Butterworth filtered results varied by 9.7% from the centre to the edge. The addition of background has an influence on the convergence rate and noise properties of iterative techniques.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The Fragile X syndrome population has susceptibility to ASD, ADHD, anxiety disorders, and neurological disorders such as epilepsy.
“This population also has susceptibility to certain other neuropsychiatric disabilities including ASD, ADHD, anxiety disorders, and neurological disorders such as epilepsy (Hessl et al., 2001; Pretorius et al., 1998).”
From Oxytocin and vasopressin systems in genetic syndromes and neurodevelopmental disorders (2014) · cites this paper as Pretorius et al., 1998
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429 · see citing works
Accelerated image reconstruction using ordered subsets of projection data
Hudson, H. M., & Larkin, R. S. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363108 · Cited by 3,713 · see citing works
EM reconstruction algorithms for emission and transmission tomography.
Lange, K. L., & Carson, R. E. (1984) · PubMed · Cited by 1,775 · see citing works
Quantitation in Positron Emission Computed Tomography
Hoffman, E. J., Huang, S., & Phelps, M. E. (1979) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-197906000-00001 · Cited by 1,145 · see citing works
A Monte Carlo program for the simulation of scintillation camera characteristics
Ljungberg, M. H., & Strand, S. (1989) · Computer Methods and Programs in Biomedicine · doi:10.1016/0169-2607(89)90111-9 · Cited by 515 · see citing works
Analysis of Emission Tomographic Scan Data: Limitations Imposed by Resolution and Background
KESSLER, R. M., Ellis, J. R., & Eden, M. (1984) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198406000-00028 · Cited by 429 · see citing works
Ichihara, T., Ogawa, K., Motomura, N., et al. (1993) · PubMed · Cited by 316 · see citing works
Zeng, G. L., Gullberg, G. T., Tsui, B. M. W., et al. (1991) · IEEE Transactions on Nuclear Science · doi:10.1109/23.289376 · Cited by 255 · see citing works
Implementation of simultaneous attenuation and detector response correction in SPECT
Tsui, B. M. W., Hu, H.-B., Gilland, D. R., & Gullberg, G. T. (1988) · IEEE Transactions on Nuclear Science · doi:10.1109/23.12831 · Cited by 238 · see citing works
Compensation of tissue absorption in emission tomography
Bellini, S., Piacentini, M., Cafforio, C., et al. (1979) · IEEE Transactions on Acoustics Speech and Signal Processing · doi:10.1109/tassp.1979.1163232 · Cited by 231 · see citing works
Block-iterative methods for image reconstruction from projections
Byrne, C. L. (1996) · IEEE Transactions on Image Processing · doi:10.1109/83.499919 · Cited by 188 · see citing works
Self-citationCompensation of spatial system response in SPECT with conjugate gradient reconstruction technique
Formiconi, A. R., Pupi, A., & Passeri, A. (1989) · Physics in Medicine and Biology · doi:10.1088/0031-9155/34/1/007 · Cited by 156 · see citing works
Glick, S. J., Penney, B. C., King, M. A., et al. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.293929 · Cited by 129 · see citing works
Self-citationZeng, G. L., & Gullberg, G. T. (1992) · IEEE Transactions on Nuclear Science · doi:10.1109/23.173222 · Cited by 125 · see citing works
Fourier correction for spatially variant collimator blurring in SPECT
Xia, W., Lewitt, R. M., & Edholm, P. (1995) · IEEE Transactions on Medical Imaging · doi:10.1109/42.370406 · Cited by 117 · see citing works
Quantitation in Positron Emission Computed Tomography
Hoffman, E. J., Huang, S., Plummer, D. L., & Phelps, M. E. (1982) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198210000-00022 · Cited by 116 · see citing works
Fourier Method For Correction Of Depth-Dependent Collimator Blurring
Lewitt, R. M., Edholm, P., & Xia, W. (1989) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.953264 · Cited by 113 · see citing works
Comparison of four scatter correction methods using Monte Carlo simulated source distributions.
Ljungberg, M. H., King, M. A., Hádemenos, G. J., et al. (1994) · PubMed · Cited by 111 · see citing works
Self-citationHawkins, W. G., Leichner, P. K., & Yang, N. (1988) · IEEE Transactions on Medical Imaging · doi:10.1109/42.3940 · Cited by 106 · see citing works
Object shape dependent PSF model for SPECT imaging
Beekman, F. J., Eijkman, E. G. J., Viergever, M. A., et al. (1993) · IEEE Transactions on Nuclear Science · doi:10.1109/23.199484 · Cited by 101 · see citing works
SPECT volume quantitation: Influence of spatial resolution, source size and shape, and voxel size
King, M. A., Long, D. T., & Brill, A. B. (1991) · Medical Physics · doi:10.1118/1.596737 · Cited by 95 · see citing works
Self-citationMaximum likelihood SPECT in clinical computation times using mesh-connected parallel computers
McCarthy, A. W., & Miller, M. I. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.97593 · Cited by 94 · see citing works
Effect of spatial resolution on SPECT quantification values.
Kojima, A., Matsumoto, M., Takahashi, M., et al. (1989) · PubMed · Cited by 94 · see citing works
Hebert, T., Leahy, R. M., & Singh, M. (1990) · Journal of the Optical Society of America A · doi:10.1364/josaa.7.001305 · Cited by 88 · see citing works
King, M. A., Xia, W., DeVries, D. J., et al. (1996) · Journal of Nuclear Cardiology · doi:10.1016/s1071-3581(96)90020-3 · Cited by 82 · see citing works
Self-citationAccelerated EM reconstruction in total-body PET: potential for improving tumour detectability
Meikle, S. R., Hutton, B. F., Bailey, D. L., Hooper, P. K., & FULHAM, M. J. (1994) · Physics in Medicine and Biology · doi:10.1088/0031-9155/39/10/012 · Cited by 81 · see citing works
Penney, B. C., King, M. A., & Knešaurek, K. (1990) · IEEE Transactions on Nuclear Science · doi:10.1109/23.106698 · Cited by 58 · see citing works
Self-citationGilland, D. R., Jaszczak, R. J., Wang, H., Turkington, T. G., Greer, K. L., & Coleman, R. E. (1994) · Physics in Medicine and Biology · doi:10.1088/0031-9155/39/3/017 · Cited by 53 · see citing works
Evaluation of OS-EM vs. ML-EM for 1D, 2D and fully 3D SPECT reconstruction
Kamphuis, C., Beekman, F. J., & Viergever, M. A. (1996) · IEEE Transactions on Nuclear Science · doi:10.1109/23.507262 · Cited by 51 · see citing works
Miller, M. I., & Butler, C. (1993) · IEEE Transactions on Medical Imaging · doi:10.1109/42.241884 · Cited by 38 · see citing works
Influence of OSEM, elliptical orbits and background activity on SPECT 3D resolution recovery
Pan, T.-S., Luo, D.-S., Kohli, V., & King, M. A. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/12/015 · Cited by 33 · see citing works
Self-citationCompensation for collimator divergence in SPECT using inverse Monte Carlo reconstruction
Floyd, C. E., Jaszczak, R. J., Manglos, S. H., & Coleman, R. E. (1988) · IEEE Transactions on Nuclear Science · doi:10.1109/23.12832 · Cited by 32 · see citing works
Pretorius, P. H., King, M. A., Glick, S. J., et al. (1996) · IEEE Transactions on Nuclear Science · doi:10.1109/23.552748 · Cited by 23 · see citing works
Self-citationClarke, L. P., LEONG, L. L., Serafini, A. N., et al. (1986) · Nuclear Medicine Communications · doi:10.1097/00006231-198605000-00006 · Cited by 14 · see citing works
King, M. A., Glick, S. J., & Penney, B. C. (1991) · IEEE Transactions on Nuclear Science · doi:10.1109/23.289385 · Cited by 14 · see citing works
Self-citationConcentration recovery for SPECT CNS dopamine‐receptor studies for monkeys
Shao, L., Billings, J. J., Pfeiffer, N., et al. (1994) · Medical Physics · doi:10.1118/1.597321 · Cited by 9 · see citing works
Measured accuracy and precision in quantitative SPECT imaging with iodine-123
Gilland, D. R., Jaszczak, R. J., Bowsher, J. E., et al. (1995) · IEEE Transactions on Nuclear Science · doi:10.1109/23.467738 · Cited by 7 · see citing works
Flagged first, then by citations
Research works printed but not linked: 1
- Gonzalez R C and Wintz P 1977 Digital Image Processing (Reading, MA: Addison-Wesley) pp 207-10
Cited by
Sorted by citations
Oxytocin and vasopressin systems in genetic syndromes and neurodevelopmental disorders
Francis, S. M., Sagar, A., Levin-Decanini, T., Liu, W., Carter, C. S., & Jacob, S. (2014) · Brain Research · doi:10.1016/j.brainres.2014.01.021 · Cited by 101 · see citing works
- Authors
- Pretorius, P. H., King, M. A., Pan, T.-S., Vries, D. J. D., Glick, S. J., & Byrne, C. L.
- Affiliations
- University of Massachusetts Chan Medical School (US)
- University of Massachusetts Lowell (US)
- ORCID
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1998-02-01
- Volume
- 43
- Issue
- 2
- Pages
- 407-420
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2108626141
- Cited by
- 72
- References
- 37
- Citations by year
- 2026: 1 · 2025: 3 · 2023: 2 · 2022: 1 · 2021: 1 · 2020: 1 · 2019: 1 · 2016: 3 · 2015: 3 · 2014: 2 · 2012: 5
- FWCI
- 2.27
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Physics in Medicine and Biology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (2r01ca042165-12)
- National Heart, Lung, and Blood Institute (R01HL050349, HL-50349)
- National Cancer Institute (CA-42165)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced X-ray and CT Imaging
- Keywords
- partial volume effect, iterative reconstruction, maximum likelihood expectation maximization, filtered backprojection, Wiener filter, background activity
- MeSH terms
- Humans, Image Processing, Computer-Assisted, Models, Theoretical, Tomography, Emission-Computed, Single-Photon, Likelihood Functions, Phantoms, Imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review