Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 635

The DOI matches its Crossref record.

High-resolution 3D Bayesian image reconstruction using the microPET small-animal scanner

Open access
Qi, Jinyi, Leahy, Richard M, Cherry, Simon R, Chatziioannou, Arion, Farquhar, Thomas H·1998·Physics in Medicine and Biology

Abstract

A Bayesian method is described for reconstruction of high-resolution 3D images from the microPET small-animal scanner. Resolution recovery is achieved by explicitly modelling the depth dependent geometric sensitivity for each voxel in combination with an accurate detector response model that includes factors due to photon pair non-collinearity and inter-crystal scatter and penetration. To reduce storage and computational costs we use a factored matrix in which the detector response is modelled using a sinogram blurring kernel. Maximum a posteriori (MAP) images are reconstructed using this model in combination with a Poisson likelihood function and a Gibbs prior on the image. Reconstructions obtained from point source data using the accurate system model demonstrate a potential for near-isotropic FWHM resolution of approximately 1.2 mm at the center of the field of view compared with approximately 2 mm when using an analytic 3D reprojection (3DRP) method with a ramp filter. These results also show the ability of the accurate system model to compensate for resolution loss due to crystal penetration producing nearly constant radial FWHM resolution of 1 mm out to a 4 mm radius. Studies with a point source in a uniform cylinder indicate that as the resolution of the image is reduced to control noise propagation the resolution obtained using the accurate system model is superior to that obtained using 3DRP at matched background noise levels. Additional studies using pie phantoms with hot and cold cylinders of diameter 1-2.5 mm and 18FDG animal studies appear to confirm this observation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0031-9155/43/4/027

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 635

Metadata

Authors
Qi, J., Leahy, R. M., Cherry, S. R., Chatziioannou, A., & Farquhar, T. H.
Venue
Physics in Medicine and Biology
Published
1998-04-01
Volume
43
Issue
4
Pages
1001-1013
ISSN
  • 0031-9155 (ISSN-L)
  • 1361-6560
OpenAlex
W2084090004
Cited by
635
References
0
FWCI
16.36
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High-resolution 3D Bayesian image reconstruction using the microPET small-animal scanner. https://app.cochat.ai/papers/10.1088/0031-9155/43/4/027
The paper
Qi, J., Leahy, R. M., Cherry, S. R., Chatziioannou, A., & Farquhar, T. H. (1998). High-resolution 3D Bayesian image reconstruction using the microPET small-animal scanner. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/43/4/027

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.