Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 261

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Megavoltage CT on a tomotherapy system

Open access
Ruchala, K J, Olivera, G H, Schloesser, E A, Mackie, T R·1999·Physics in Medicine and Biology

Abstract

A megavoltage computed tomography (MVCT) system was developed on the University of Wisconsin tomotherapy benchtop. This system can operate either axially or helically, and collect transmission data without any bounds on delivered dose. Scan times as low as 12 s per slice are possible, and scans were run with linac output rates of 100 MU min(-1), although the system can be tuned to deliver arbitrarily low dose rates. Images were reconstructed with clinically reasonable doses ranging from 8 to 12 cGy. These images delineate contrasts below 2% and resolutions of 3.0 mm. Thus, the MVCT image quality of this system should be sufficient for verifying the patient's position and anatomy prior to radiotherapy. Additionally, synthetic data were used to test the potential for improved MVCT contrast using maximum-likelihood (ML) reconstruction. Specifically, the maximum-likelihood expectation-maximization (ML-EM) algorithm and a transmission ML algorithm were compared with filtered backprojection (FBP). It was found that for expected clinical MVCT doses enough imaging photons are used such that little benefit is conferred by the improved noise model of ML algorithms. For significantly lower doses, some quantitative improvement is achieved through ML reconstruction. Nonetheless, the image quality at those lower doses is not satisfactory for radiotherapy verification.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0031-9155/44/10/316

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 261

Metadata

Authors
Ruchala, K. J., Olivera, G. H., Schloesser, E. A., & Mackie, T. R.
Venue
Physics in Medicine and Biology
Published
1999-09-22
Volume
44
Issue
10
Pages
2597-2621
ISSN
  • 0031-9155 (ISSN-L)
  • 1361-6560
OpenAlex
W2053683763
Cited by
261
References
3
FWCI
12.43
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Megavoltage CT on a tomotherapy system. https://app.cochat.ai/papers/10.1088/0031-9155/44/10/316
The paper
Ruchala, K. J., Olivera, G. H., Schloesser, E. A., & Mackie, T. R. (1999). Megavoltage CT on a tomotherapy system. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/44/10/316

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.