Megavoltage CT on a tomotherapy system
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
A megavoltage computed tomography (MVCT) system was developed on the University of Wisconsin tomotherapy benchtop. This system can operate either axially or helically, and collect transmission data without any bounds on delivered dose. Scan times as low as 12 s per slice are possible, and scans were run with linac output rates of 100 MU min(-1), although the system can be tuned to deliver arbitrarily low dose rates. Images were reconstructed with clinically reasonable doses ranging from 8 to 12 cGy. These images delineate contrasts below 2% and resolutions of 3.0 mm. Thus, the MVCT image quality of this system should be sufficient for verifying the patient's position and anatomy prior to radiotherapy. Additionally, synthetic data were used to test the potential for improved MVCT contrast using maximum-likelihood (ML) reconstruction. Specifically, the maximum-likelihood expectation-maximization (ML-EM) algorithm and a transmission ML algorithm were compared with filtered backprojection (FBP). It was found that for expected clinical MVCT doses enough imaging photons are used such that little benefit is conferred by the improved noise model of ML algorithms. For significantly lower doses, some quantitative improvement is achieved through ML reconstruction. Nonetheless, the image quality at those lower doses is not satisfactory for radiotherapy verification.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Handbook of Mathematical Functions
McQuarrie, D. A. (1966) · American Journal of Physics · doi:10.1119/1.1972842 · Cited by 40,433
Principles of Computerized Tomographic Imaging
Kak, A. C., & Slaney, M. (2001) · doi:10.1137/1.9780898719277 · Cited by 5,809
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
Accelerated image reconstruction using ordered subsets of projection data
Hudson, H. M., & Larkin, R. S. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363108 · Cited by 3,711
Introduction to Radiological Physics and Radiation Dosimetry
Attix, F. H. (1986) · Wiley eBooks · doi:10.1002/9783527617135 · Cited by 1,868
EM reconstruction algorithms for emission and transmission tomography.
Lange, K. L., & Carson, R. E. (1984) · PubMed · Cited by 1,769
A row-action alternative to the EM algorithm for maximizing likelihood in emission tomography
Browne, J., & de Pierro, A. B. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.538946 · Cited by 424
Noise and Edge Artifacts in Maximum-Likelihood Reconstructions for Emission Tomography
Snyder, D. L., Miller, M. I., Thomas, L. J., & Politte, D. G. (1987) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1987.4307831 · Cited by 421
An Improved Algorithm for Reprojecting Rays through Pixel Images
Joseph, P. M. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307572 · Cited by 375
A Theoretical Study of Some Maximum Likelihood Algorithms for Emission and Transmission Tomography
Lange, K., Bahn, M., & Little, R. (1987) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1987.4307810 · Cited by 330
Cited by
Sources and effects of ionizing radiation
(2018) · United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) Reports · doi:10.18356/f48d655d-en · Cited by 3,985
Flat-panel cone-beam computed tomography for image-guided radiation therapy
Jaffray, D. A., Siewerdsen, J. H., Wong, J. W., & Martinez, A. A. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02884-5 · Cited by 1,330
Intensity-modulated radiotherapy: current status and issues of interest
(2001) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(01)01749-7 · Cited by 767
Advances in Image-Guided Radiation Therapy
Dawson, L. A., & Jaffray, D. A. (2007) · Journal of Clinical Oncology · doi:10.1200/jco.2006.09.9515 · Cited by 420
Low-dose megavoltage cone-beam CT for radiation therapy
Pouliot, J., Bani-Hashemi, A., Chen, J., Svatos, M., Ghelmansarai, F., Mitschke, M., Aubin, M., Xia, P., Morin, O., Bucci, K., et al. (2005) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2004.10.011 · Cited by 374
Bissonnette, J., Balter, P. A., Dong, L., Langen, K. M., Lovelock, D. M., Miften, M., Moseley, D. J., Pouliot, J., Sonke, J., & Yoo, S. (2012) · Medical Physics · doi:10.1118/1.3690466 · Cited by 359
QA for helical tomotherapy: Report of the AAPM Task Group 148a)
Langen, K. M., Papanikolaou, N., Balog, J., Crilly, R., Followill, D., Goddu, S. M., Grant, W., Olivera, G., Ramsey, C. R., & Shi, C. (2010) · Medical Physics · doi:10.1118/1.3462971 · Cited by 275
Self-citationOnline Adaptive Radiation Therapy
Lim-Reinders, S., Keller, B. M., Al-Ward, S., Sahgal, A., & Kim, A. (2017) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2017.04.023 · Cited by 267
Raaymakers, B. W., Raaijmakers, A. J. E., Kotte, A. N. T. J., Jette, D., & Lagendijk, J. J. W. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/17/019 · Cited by 253
Zhang, T., Chi, Y., Meldolesi, E., & Yan, D. (2007) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2007.01.038 · Cited by 177
Lu, W., Olivera, G. H., Chen, Q., Ruchala, K. J., Haimerl, J., Meeks, S. L., Langen, K. M., & Kupelian, P. A. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/17/015 · Cited by 159
Self-citation
Metadata
- Authors
- Ruchala, K. J., Olivera, G. H., Schloesser, E. A., & Mackie, T. R.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1999-09-22
- Volume
- 44
- Issue
- 10
- Pages
- 2597-2621
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2053683763
- Cited by
- 261
- References
- 34
- FWCI
- 12.43
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.