The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Physical model for the spectroscopic analysis of cortical intrinsic optical signals
Abstract
We used Monte Carlo simulations and the diffusion approximation to estimate correction terms for the analysis of reflectance spectra of cortical intrinsic optical signals. These corrections depend on scattering and absorption properties, i.e. they are dependent on assumptions on the tissue blood content and oxygen saturation. The analysis was applied to reflectance spectra acquired during whisker barrel stimulation in the rat where attenuation spectra were converted to changes in oxygenated and deoxygenated haemoglobin concentration. The description of the experimental data as judged by the residual and sensitivity to variations of wavelength was considerably improved when the correction terms were included. Inclusion of the correction does have a considerable impact on the time course of deoxyhaemoglobin concentration changes. In contrast to the calculation without correction terms, there is no indication for an early increase in deoxyhaemoglobin ('early dip'). This finding might further current interpretation of the coupling between neuronal activation and oxygen extraction and supply.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530
Cited by
Strangman, G., Culver, J. P., Thompson, J. H., & Boas, D. A. (2002) · NeuroImage · doi:10.1006/nimg.2002.1227 · Cited by 1,415
Diffuse optics for tissue monitoring and tomography
Durduran, T., Choe, R., Baker, W. B., & Yodh, A. G. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/7/076701 · Cited by 1,161
Boas, D. A., Dale, A. M., & Franceschini, M. A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.011 · Cited by 721
Optical brain imaging in vivo: techniques and applications from animal to man
Hillman, E. M. C. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2789693 · Cited by 436
Devor, A., Dunn, A. K., Andermann, M. L., Ulbert, I., Boas, D. A., & Dale, A. M. (2003) · Neuron · doi:10.1016/s0896-6273(03)00403-3 · Cited by 387
Metadata
- Authors
- Kohl, M., Lindauer, U., Royl, G., Kühl, M., Gold, L., Villringer, A., & Dirnagl, U.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2000-11-21
- Volume
- 45
- Issue
- 12
- Pages
- 3749-3764
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2010968771
- Cited by
- 176
- References
- 1
- FWCI
- 5.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Physical model for the spectroscopic analysis of cortical intrinsic optical signals. https://app.cochat.ai/papers/10.1088/0031-9155/45/12/317
- The paper
- Kohl, M., Lindauer, U., Royl, G., Kühl, M., Gold, L., Villringer, A., & Dirnagl, U. (2000). Physical model for the spectroscopic analysis of cortical intrinsic optical signals. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/45/12/317
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.