The GSF family of voxel phantoms
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Voxel phantoms are human models based on computed tomographic or magnetic resonance images obtained from high-resolution scans of a single individual. They consist of a huge number of volume elements (voxels) and are at the moment the most precise representation of the human anatomy. The purpose of this paper is to introduce the GSF voxel phantoms, with emphasis on the new ones and highlight their characteristics and limitations. The GSF voxel family includes at the moment two paediatric and five adult phantoms of both sexes, different ages and stature and several others are under construction. Two phantoms made of physical calibration phantoms are also available to be used for validation purposes. The GSF voxel phantoms tend to cover persons of individual anatomy and were developed to be used for numerical dosimetry of radiation transport but other applications are also possible. Examples of applications in patient dosimetry in diagnostic radiology and in nuclear medicine as well as for whole-body irradiations from idealized external exposures are given and discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
MCNP-A General Monte Carlo N-Particle Transport Code
Briesmeister, J. F. (1993) · Cited by 5,110
Computerized three‐dimensional segmented human anatomy
Zubal, I. G., Harrell, C. R., Smith, E. O., Rattner, Z., Gindi, G., & Hoffer, P. B. (1994) · Medical Physics · doi:10.1118/1.597290 · Cited by 1,103
THE INTERNATIONAL COMMISSION ON RADIATION UNITS AND MEASUREMENTS
Wambersie, A. (2004) · Journal of the ICRU · doi:10.1093/jicru/ndh019 · Cited by 869
Specific absorbed fractions of energy at various ages from internal photon sources: 6, Newborn
Cristy, M., & Eckerman, K. F. (1987) · doi:10.2172/6202949 · Cited by 692
Active bone marrow distribution as a function of age in humans
Cristy, M. (1981) · Physics in Medicine & Biology · doi:10.1088/0031-9155/26/3/003 · Cited by 411
Xu, X. G., Chao, T. C., & Bozkurt, A. (2000) · Health Physics · doi:10.1097/00004032-200005000-00003 · Cited by 364
The adult male voxel model ”Golem" segmented from whole-body CT patient data
Zankl, M., & Wittmann, A. (2001) · Radiation and Environmental Biophysics · doi:10.1007/s004110100094 · Cited by 207
Self-citationZankl, M., Veit, R., Williams, G., Schneider, K., Fendel, H., Petoussi, N., & Drexler, G. (1988) · Radiation and Environmental Biophysics · doi:10.1007/bf01214605 · Cited by 172
Self-citationTsui, B. M. W., Terry, J. A., & Gullberg, G. T. (1993) · Investigative Radiology · doi:10.1097/00004424-199312000-00004 · Cited by 138
Caon, M., Bibbo, G., & Pattison, J. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/9/309 · Cited by 123
Cited by
Sources and effects of ionizing radiation
(2018) · United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) Reports · doi:10.18356/f48d655d-en · Cited by 3,985
Valentin, J. (2002) · Annals of the ICRP · doi:10.1016/s0146-6453(03)00002-2 · Cited by 1,754
Gosselin, M.-C., Neufeld, E., Moser, H., Huber, E., Farcito, S., Gerber, L., Jedensjö, M., Hilber, I., Gennaro, F. D., Lloyd, B., et al. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/18/5287 · Cited by 520
“An 8 week old baby girl, Charlie, is also included and has been adapted from the voxel baby developed by the Helmholtz Zentrum München (previously known as Gesellschaft für Strahlenforschung, or GSF) (Petoussi-Henss et al 2002) to be consistent with the segmentation guidelines.”
MethodRealistic CT simulation using the 4D XCAT phantom
Segars, W. P., Mahesh, M., Beck, T. J., Frey, E. C., & Tsui, B. M. W. (2008) · Medical Physics · doi:10.1118/1.2955743 · Cited by 412
Xu, X. G. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/18/r233 · Cited by 280
MIDA: A Multimodal Imaging-Based Detailed Anatomical Model of the Human Head and Neck
Iacono, M. I., Neufeld, E., Akinnagbe, E., Bower, K., Wolf, J., Vogiatzis Oikonomidis, I., Sharma, D., Lloyd, B., Wilm, B. J., Wyss, M., et al. (2015) · PLOS ONE · doi:10.1371/journal.pone.0124126 · Cited by 273
Zaidi, H., & Xu, X. G. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.060906.151934 · Cited by 219
“(61, 62) from the National Research Center for Environment and Health (GSF), Germany, developed a family of nine tomographic models, all from CT images: BABY, CHILD, DONNA, FRANK, GOLEM, HELGA, IRENE, LAURA, and VISIBLE MAN.”
Voxel-based computational models of real human anatomy: a review
Caon, M. (2004) · Radiation and Environmental Biophysics · doi:10.1007/s00411-003-0221-8 · Cited by 213
How Effective Is Effective Dose as a Predictor of Radiation Risk?
McCollough, C. H., Christner, J. A., & Kofler, J. M. (2010) · American Journal of Roentgenology · doi:10.2214/ajr.09.4179 · Cited by 169
“[46] have published voxel phantoms (i.”
DeMarco, J. J., Cagnon, C. H., Cody, D. D., Stevens, D. M., McCollough, C. H., O'Daniel, J., & McNitt-Gray, M. F. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/17/005 · Cited by 161
Kainz, W., Neufeld, E., Bolch, W. E., Graff, C. G., Kim, C. H., Kuster, N., Lloyd, B., Morrison, T., Segars, P., Yeom, Y. S., et al. (2019) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2018.2883437 · Cited by 109
“One exception is the eight-week-old baby model generated from image data of a dead infant [90].”
Self-citationFranck, C., Vandevoorde, C., Goethals, I., Smeets, P., Achten, E., Verstraete, K., Thierens, H., & Bacher, K. (2016) · European Radiology · doi:10.1007/s00330-015-4091-7 · Cited by 43
Metadata
- Authors
- Petoussi-Henss, N., Zankl, M., Fill, U., & Regulla, D.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2001-12-19
- Volume
- 47
- Issue
- 1
- Pages
- 89-106
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2092218552
- Cited by
- 280
- References
- 15
- FWCI
- 6.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.