Development of a new generation of high-resolution anatomical models for medical device evaluation: the Virtual Population 3.0
Open accessThe DOI matches its Crossref record; 51 of the 52 references it cites were found in a registry or an index.
Abstract
The Virtual Family computational whole-body anatomical human models were originally developed for electromagnetic (EM) exposure evaluations, in particular to study how absorption of radiofrequency radiation from external sources depends on anatomy. However, the models immediately garnered much broader interest and are now applied by over 300 research groups, many from medical applications research fields. In a first step, the Virtual Family was expanded to the Virtual Population to provide considerably broader population coverage with the inclusion of models of both sexes ranging in age from 5 to 84 years old. Although these models have proven to be invaluable for EM dosimetry, it became evident that significantly enhanced models are needed for reliable effectiveness and safety evaluations of diagnostic and therapeutic applications, including medical implants safety. This paper describes the research and development performed to obtain anatomical models that meet the requirements necessary for medical implant safety assessment applications. These include implementation of quality control procedures, re-segmentation at higher resolution, more-consistent tissue assignments, enhanced surface processing and numerous anatomical refinements. Several tools were developed to enhance the functionality of the models, including discretization tools, posing tools to expand the posture space covered, and multiple morphing tools, e.g., to develop pathological models or variations of existing ones. A comprehensive tissue properties database was compiled to complement the library of models. The results are a set of anatomically independent, accurate, and detailed models with smooth, yet feature-rich and topologically conforming surfaces. The models are therefore suited for the creation of unstructured meshes, and the possible applications of the models are extended to a wider range of solvers and physics. The impact of these improvements is shown for the MRI exposure of an adult woman with an orthopedic spinal implant. Future developments include the functionalization of the models for specific physical and physiological modeling tasks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Each model is made up of over 300 tissues, with a supporting database of electromagnetic properties for each tissue.”
From Credibility assessment of in silico clinical trials for medical devices (2024) · cites this paper as [30]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“The Virtual Population [30] is a set of human models for electromagnetic simulations that have been created for these purposes.”
From Credibility assessment of in silico clinical trials for medical devices (2024) · cites this paper as [30]
The cited source says what the claim attributes to it.
In the citing paper
“MR-induced heating ISCTs using the virtual patients such as the Virtual Population [30] often focus validation efforts on the device model (e.g., clause 8.7.5 in ISO/TS 10974 [28]), rather than the patient model or coupled device-patient model.”
From Credibility assessment of in silico clinical trials for medical devices (2024) · cites this paper as [30]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175 · cited 1×
“The assignment of the dielectric tissue properties at 64 MHz was done according to the material database (see section 2.2.4), which includes work presented in Gabriel et al (1996), and all metallic parts of the coil and the implant were treated as perfect electrical conductors.”
MethodInfluentialde Onís, M., Onyango, A. W., Borghi, E., Siyam, A., Pinol, A., Garza, C., Martines, J., Martorell, R., Victora, C. G., Bhan, M. K., et al. (2006) · (2006) · Cited by 3,401
Lanczos Filtering in One and Two Dimensions
Duchon, C. E. (1979) · Journal of Applied Meteorology · doi:10.1175/1520-0450(1979)018<1016:lfioat>2.0.co;2 · Cited by 2,398 · cited 3×
“It was tuned with lumped elements placed at the end rings between the rungs to match previously performed measurements (Cabot et al 2013). Due to the high resolution required by the implant and the large simulation domain required by the birdcage coil, the computation was performed in two steps: the fields in the bird…”
MethodInfluentialEfficient Management of Parallelism in Object-Oriented Numerical Software Libraries
Balay, S., Gropp, W. D., McInnes, L. C., & Smith, B. F. (1997) · Modern Software Tools for Scientific Computing · doi:10.1007/978-1-4612-1986-6_8 · Cited by 2,009 · cited 1×
“Dedicated high performance computing-enabled solvers, based on the PETSc framework (Balay et al 1997), have been developed for this purpose.”
MethodReport of the task group on reference man
(1979) · Annals of the ICRP · doi:10.1016/0146-6453(79)90123-4 · Cited by 1,706
Medical Image Computing and Computer-Assisted Intervention
Yang, G., Hawkes, D. J., Rueckert, D., Noble, J. A., & Taylor, C. (2009) · Research Explorer (The University of Manchester) · Cited by 1,591
Christ, A., Kainz, W., Hahn, E. G., Honegger, K., Zefferer, M., Neufeld, E., Rascher, W., Janka, R., Bautz, W., Chen, J., et al. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/2/n01 · Cited by 1,439 · cited 2×
“Pregnant women models at three gestational stages presented in Christ et al (2012) are included in the Virtual Population.”
BackgroundMethodSelf-citationComputerized three‐dimensional segmented human anatomy
Zubal, I. G., Harrell, C. R., Smith, E. O., Rattner, Z., Gindi, G., & Hoffer, P. B. (1994) · Medical Physics · doi:10.1118/1.597290 · Cited by 1,103
Automatic three‐dimensional mesh generation by the finite octree technique
Shephard, M. S., & Georges, M. K. (1991) · International Journal for Numerical Methods in Engineering · doi:10.1002/nme.1620320406 · Cited by 732
amira: A Highly Interactive System for Visual Data Analysis
STALLING, D., WESTERHOFF, M., & HEGE, H.-C. (2005) · Visualization Handbook · doi:10.1016/b978-012387582-2/50040-x · Cited by 569 · cited 1×
“Also, the surface extraction and processing have been updated: previously, the surface extraction, simplification, and smoothing routines from the Amira software (Stalling et al 2005) were used.”
Method
Research works printed but not linked: 6
- Benkler S, Chavannes N and Kuster N 2009 New powerful FDTD source based on Huygens surface: highly complex EM simulations performed on an ordinary PC Abstract Collection of BioEM 2009 Davos: the Joint Meeting of the Bioelectromagnetics Society and the European BioElectromagnetics Association (Davos, Switzerland 14-19 June) (Poster presentation P-262 in Poster session 2: Theoretical and Practical Modeling (June 16)) pp 736-7
- Cherubini E, Chavannes N and Kuster N 2008 Realistic skeleton based deformation of high-resolution anatomical human models for electromagnetic simulation BEMS 2008: Abstracts of the 30th Annu. Meeting of the Bioelectromagnetics Society (San Diego, CA, USA, 9-12 June) pp 505-7 (Poster Presentation P-149 in Poster Session: Theoretical and Practical Modeling) (10 June))
- Cristy M 1980 Mathematical phantoms representing children of various ages for use in estimates of internal dose Oak Ridge National Laboratory Technical Report ORNL (Oak Ridge, TN: ORNL)
- Neufeld E, Szczerba D and Kuster N 2013b Mechanical simulation-based approach for realistic model shape and posture parametrization CP'13: 4th Int. Workshop on Computational Phantoms for Radiation Protection, Imaging and Radiotherapy (Zurich, 20-22 May) pp 14-5
- Sempé M, Pédron G and Roy-Pernot M-P 1979 Auxologie: méthode et séquences Théraplix (Paris: Theraplix)
- Spurway J F, 2004, ASUM Ultrasound Bull., 7, 15
Cited by
Xu, X. G. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/18/r233 · Cited by 280
MIDA: A Multimodal Imaging-Based Detailed Anatomical Model of the Human Head and Neck
Iacono, M. I., Neufeld, E., Akinnagbe, E., Bower, K., Wolf, J., Vogiatzis Oikonomidis, I., Sharma, D., Lloyd, B., Wilm, B. J., Wyss, M., et al. (2015) · PLOS ONE · doi:10.1371/journal.pone.0124126 · Cited by 273
Self-citationPanych, L. P., & Madore, B. (2017) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25761 · Cited by 220
MRI‐Related Heating of Implants and Devices: A Review
Winter, L., Seifert, F. C., Zilberti, L., Murbach, M., & Ittermann, B. (2020) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.27194 · Cited by 188
Morrison, T. M., Pathmanathan, P., Adwan, M., & Margerrison, E. (2018) · Frontiers in Medicine · doi:10.3389/fmed.2018.00241 · Cited by 186
“…mechanical activity in the heart (30); energy absorption in patients with deep-brain stimulators (31– 34), breast tissue expanders (35), in pregnant women and fetus during MRI exams (36); subthalamic nucleus (37), the breast (38), cancellous bone (39), the head (40) and whole body models (41, 42).”
Background
Metadata
- Authors
- Gosselin, M.-C., Neufeld, E., Moser, H., Huber, E., Farcito, S., Gerber, L., Jedensjö, M., Hilber, I., Gennaro, F. D., Lloyd, B., Cherubini, E., Szczerba, D., Kainz, W., & Kuster, N.
- Affiliations
- ETH Zurich (CH)
- Foundation for Research on Information Technologies in Society (CH)
- United States Food and Drug Administration (US)
- Corresponding author
- Gosselin, Marie-Christine
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2014-08-21
- Volume
- 59
- Issue
- 18
- Pages
- 5287-5303
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2102862641
- Cited by
- 520
- References
- 52
- Citations by year
- 2026: 34 · 2025: 64 · 2024: 44 · 2023: 50 · 2022: 61 · 2021: 52 · 2020: 53 · 2019: 45 · 2018: 42 · 2017: 35 · 2016: 20 · 2015: 14 · 2014: 3
- FWCI
- 12.45
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- iopscience.iop.org/page/copyright (vor)
- Locations
- Physics in Medicine and Biology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- European Commission (FP7/2007, 282891)
- Eidgenössische Technische Hochschule Zürich
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Anatomy and Medical Technology
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Electromagnetic Fields and Biological Effects
- Keywords
- virtual population, MRI safety, spinal implants, surface processing, electromagnetic dosimetry, radiofrequency exposure, unstructured grid
- MeSH terms
- Adolescent, Adult, Aged, Aged, 80 and over, Child, Child, Preschool, Computer Simulation, Equipment and Supplies, Female, Humans, Image Processing, Computer-Assisted, Magnetic Resonance Imaging, Male, Middle Aged, Models, Anatomic, Models, Theoretical, Radiometry, Surface Properties, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development of a new generation of high-resolution anatomical models for medical device evaluation: the Virtual Population 3.0. https://app.cochat.ai/papers/10.1088/0031-9155/59/18/5287
- The paper
- Gosselin, M.-C., Neufeld, E., Moser, H., Huber, E., Farcito, S., Gerber, L., Jedensjö, M., Hilber, I., Gennaro, F. D., Lloyd, B., Cherubini, E., Szczerba, D., Kainz, W., & Kuster, N. (2014). Development of a new generation of high-resolution anatomical models for medical device evaluation: the Virtual Population 3.0. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/59/18/5287
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.