A kinetic model for dynamic [18F]-Fmiso PET data to analyse tumour hypoxia
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
A method is presented to identify and quantify hypoxia in human head-and-neck tumours based on dynamic [18F]-Fmiso PET patient data, using a model for the tracer transport. A compartmental model was developed, inspired by recent immunohistochemical investigations with the tracer pimonidazole. In order to take the trapping of the tracer and the diffusion in interstitial space into account, the kinetic model consists of two compartments and a specific input function. This voxel-based data analysis allows us to decompose the time-activity curves (TACs) into their perfusion, diffusion and hypoxia-induced retention components. This characterization ranges from well perfused tumours over diffusion limited hypoxia to strong hypoxia and necrosis. The overall shape of the TAC and the model parameters may point at the structural architecture of the tissue sample. The model addresses the two main problems associated with hypoxia imaging with PET. Firstly, the hypoxic areas are spatially separated from well perfused vessels, causing long diffusion times of the tracer. Secondly, tracer uptake occurs only in viable hypoxic cells, which constitute only a small subpopulation in the presence of necrosis. The resulting parameters such as the concentration of hypoxic cells and the perfusion are displayed in parameter plots ('hypoxia map'). Quantification of hypoxia performed with the presented kinetic model is more reliable than a criterion based on static standardized uptake values (SUV) at an early timepoint, because severely hypoxic/necrotic tissues show low uptake and are thus overlooked by SUV threshold identification. The derived independent measures for perfusion and hypoxia may provide a basis for individually adapted treatment planning.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Numerical recipes in C: the art of scientific computing
(1993) · Choice Reviews Online · doi:10.5860/choice.30-5638 · Cited by 17,933
Alignment by Maximization of Mutual Information
Viola, P., & Wells III, W. M. (1997) · International Journal of Computer Vision · doi:10.1023/a:1007958904918 · Cited by 2,610
Transport of molecules in the tumor interstitium: a review.
Jain, R. K. (1987) · PubMed · Cited by 1,378
Numerical recipes in C (2nd ed.): the art of scientific computing
Press, W. H., Teukolsky, S. A., Vetterling, W. T., & Flannery, B. P. (1992) · Cambridge University Press eBooks · Cited by 1,156
Nordsmark, M., Overgaard, M., & Overgaard, J. (1996) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(96)91811-3 · Cited by 942
Rasey, J. S., Koh, W.-J., Evans, M. L., Peterson, L. M., Lewellen, T. K., Graham, M. M., & Krohn, K. A. (1996) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(96)00325-2 · Cited by 562
Imaging of hypoxia in human tumors with [F-18]fluoromisonidazole
Koh, W.-J., Rasey, J. S., Evans, M. L., Grierson, J. R., Lewellen, T. K., Graham, M. M., Krohn, K. A., & Griffin, T. W. (1992) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(92)91001-4 · Cited by 463 · cited 2×
“Koh et al (1992) and Rasey et al (1996) developed a strategy for the identification and quantification of hypoxic tumour areas on the basis of Fmiso PET images.”
MethodChao, K. S. C., Bosch, W. R., Mutic, S., Lewis, J. S., Dehdashti, F., Mintun, M. A., Dempsey, J. F., Perez, C. A., Purdy, J. A., & Welch, M. J. (2001) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(00)01433-4 · Cited by 429
Nordsmark, M., & Overgaard, J. (2000) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(00)00223-1 · Cited by 281
ARCON: a novel biology-based approach in radiotherapy
Kaanders, J. H., Bussink, J., & van der Kogel, A. J. (2002) · The Lancet Oncology · doi:10.1016/s1470-2045(02)00929-4 · Cited by 256
Imaging perfusion and hypoxia with PET to predict radiotherapy response in head-and-neck cancer
Lehtiö, K., Eskola, O., Viljanen, T., Oikonen, V., Grönroos, T., Sillanmäki, L., Grénman, R., & Minn, H. (2004) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2003.12.014 · Cited by 176 · cited 2×
“There have been several attempts to quantify tumour hypoxia with polarographic needle electrodes (Nordsmark et al 1996, 2000) or with positron emission tomography (PET) by using hypoxia-specific tracer molecules such as [60Cu]-ATSM (Chao et al 2001), [18F]Fluoroerythronitroimidazole (FETNIM) (Lehtiö et al 2004), [18F…”
MethodLjungkvist, A. S. E., Bussink, J., Rijken, P. F. J. W., Kaanders, J. H. A. M., van der Kogel, A. J., & Denekamp, J. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02938-3 · Cited by 146
Janssen, H. L., Haustermans, K. M., Sprong, D., Blommestijn, G. J. F., Hofland, I., Hoebers, F. J. P., Blijweert, E., Raleigh, J. A., Semenza, G. L., Varia, M. A., et al. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)03935-4 · Cited by 133 · cited 4×
“This property is understandable by the immunohistochemical investigations with pimonidazole (Ljungkvist et al 2002, Janssen et al 2002, 2004) that found that long diffusion distances had to be travelled by the tracer before reaching hypoxic cells.”
BackgroundResultInfluentialBlood Perfusion and Microenvironment of Human Tumors
(2000) · Medical radiology · doi:10.1007/978-3-642-58813-6 · Cited by 128
Bentzen, L., Keiding, S., Nordsmark, M., Falborg, L., Hansen, S. B., Keller, J. O., Nielsen, O. S., & Overgaard, J. (2003) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(03)00081-1 · Cited by 127 · cited 2×
“A study by Bentzen et al (2003) reports on an unclear correlation between Fmiso PET scans and direct oxygen measurements with polarographic needle electrodes.”
BackgroundMethodHicks, K., Ohms, S., van Zijl, P., Denny, W., Hunter, P., & Wilson, W. (1997) · British Journal of Cancer · doi:10.1038/bjc.1997.481 · Cited by 92 · cited 1×
“For a compartmental model, the consequence of this diffusion delay will be a translation of the spatial separation of blood pool and tracer trapping into a temporal separation (Hicks et al 1997).”
Inducible Repair and the Two Forms of Tumour Hypoxia - Time for a Paradigm Shift
Denekamp, J., & Daşu, A. (1999) · Acta Oncologica · doi:10.1080/028418699432590 · Cited by 82 · cited 1×
“Also, temporary stasis has been described in tumours (Denekamp and Daşu 1999).”
BackgroundDifferentiation-associated staining with anti-pimonidazole antibodies in head and neck tumors
Janssen, H. L., Hoebers, F. J. P., Sprong, D., Goethals, L., Williams, K. J., Stratford, I. J., Haustermans, K. M., Balm, A. J. M., & Begg, A. C. (2004) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2003.09.012 · Cited by 32 · cited 1×
“The presented investigation showed that the overall shapes of the TACs contain essential information about hypoxic tumour areas. Particularly the behaviour of the curves at long time scales is important. Hence, a criterion based on a single time point threshold is not sufficient to perform a reliable hypoxia analysis.…”
BackgroundThe Potential Role of Positron Emission Tomography in Investigation of Microenvironment
Laubenbacher, C., & Schwaiger, M. (2000) · Medical radiology · doi:10.1007/978-3-642-58813-6_15 · Cited by 3 · cited 1×
“In the presence of oxygen, the favoured reaction is the re-oxygenation to the less reactive parent compound which is freely diffusible and clears from tissue (Laubenbacher and Schwaiger 2000).”
Background
Cited by
Fass, L. (2008) · Molecular Oncology · doi:10.1016/j.molonc.2008.04.001 · Cited by 822
Use of PET and PET/CT for Radiation Therapy Planning: IAEA expert report 2006–2007
MacManus, M., Nestle, U., Rosenzweig, K. E., Carrio, I., Messa, C., Belohlavek, O., Danna, M., Inoue, T., Deniaud-Alexandre, E., Schipani, S., et al. (2009) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2008.11.008 · Cited by 367
Hypoxia Dose Painting by Numbers: A Planning Study
Thorwarth, D., Eschmann, S.-M., Paulsen, F., & Alber, M. (2007) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2006.11.061 · Cited by 301
Self-citationPET/MRI for Neurologic Applications
Catana, C., Drzezga, A., Heiss, W.-D., & Rosen, B. R. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.105346 · Cited by 288
Lee, N. Y., Mechalakos, J. G., Nehmeh, S., Lin, Z., Squire, O. D., Cai, S., Chan, K., Zanzonico, P. B., Greco, C., Ling, C. C., et al. (2008) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2007.06.039 · Cited by 235
“In the latter method, the kinetic information of the tracer uptake and retention behavior in each PET image voxel is used to generate parametric maps of putative hypoxia tracer trapping using compartmental models of the tracer binding chemistry (71,72).”
BackgroundMethod
Metadata
- Authors
- Thorwarth, D., Eschmann, S. M., Paulsen, F., & Alber, M.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2005-04-27
- Volume
- 50
- Issue
- 10
- Pages
- 2209-2224
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2048619131
- Cited by
- 164
- References
- 19
- FWCI
- 6.90
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.