Optical and acoustic properties at 1064 nm of polyvinyl chloride-plastisol for use as a tissue phantom in biomedical optoacoustics
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A novel optoacoustic phantom made of polyvinyl chloride-plastisol (PVCP) for optoacoustic studies is described. The optical and acoustic properties of PVCP were measured. Titanium dioxide (TiO2) powder and black plastic colour (BPC) were used to introduce scattering and absorption, respectively, in the phantoms. The optical absorption coefficient (mua) at 1064 nm was determined using an optoacoustic method, while diffuse reflectance measurements were used to obtain the optical reduced scattering coefficient (mu's). These optical properties were calculated to be mua = (12.818 +/- 0.001)ABPC cm(-1) and mu's = (2.6 +/- 0.2)S(TiO2) + (1.4 +/- 0.1) cm(-1), where ABPC is the BPC per cent volume concentration, and S(TiO2) is the TiO2 volume concentration (mg mL(-1)). The speed of sound in PVCP was measured to be (1.40 +/- 0.02) x 10(3) m s(-1) using the pulse echo transmit receive method, with an acoustic attenuation of (0.56 +/- 1.01) f(1.51+/-0.06)MHz (dB cm(-1)) in the frequency range of 0.61-1.25 MHz, and a density, calculated by measuring the displacement of water, of 1.00 +/- 0.04 g cm(-3). The speed of sound and density of PVCP are similar to tissue, and together with the user-adjustable optical properties, make this material well suited for developing tissue-equivalent phantoms for biomedical optoacoustics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530 · cited 1×
“Optical properties of these materials can be characterized using numerous techniques, including diffuse reflection, diffuse or collimated transmission and optoacoustic spectroscopy (Cheong et al 1990, Welch and van Gemert 1995).”
Background
Cited by
Acoustical properties of selected tissue phantom materials for ultrasound imaging
Zell, K., Sperl, J. I., Vogel, M. W., Niessner, R., & Haisch, C. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/20/n02 · Cited by 336
Wells, P. N. T. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/13/r06 · Cited by 287
Metadata
- Authors
- Spirou, G. M., Oraevsky, A. A., Vitkin, I. A., & Whelan, W. M.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2005-06-28
- Volume
- 50
- Issue
- 14
- Pages
- N141-N153
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2158286341
- Cited by
- 177
- References
- 1
- FWCI
- 2.65
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optical and acoustic properties at 1064 nm of polyvinyl chloride-plastisol for use as a tissue phantom in biomedical optoacoustics. https://app.cochat.ai/papers/10.1088/0031-9155/50/14/n01
- The paper
- Spirou, G. M., Oraevsky, A. A., Vitkin, I. A., & Whelan, W. M. (2005). Optical and acoustic properties at 1064 nm of polyvinyl chloride-plastisol for use as a tissue phantom in biomedical optoacoustics. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/50/14/n01
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.