Large deformation three-dimensional image registration in image-guided radiation therapy
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
In this paper, we present and validate a framework, based on deformable image registration, for automatic processing of serial three-dimensional CT images used in image-guided radiation therapy. A major assumption in deformable image registration has been that, if two images are being registered, every point of one image corresponds appropriately to some point in the other. For intra-treatment images of the prostate, however, this assumption is violated by the variable presence of bowel gas. The framework presented here explicitly extends previous deformable image registration algorithms to accommodate such regions in the image for which no correspondence exists. We show how to use our registration technique as a tool for organ segmentation, and present a statistical analysis of this segmentation method, validating it by comparison with multiple human raters. We also show how the deformable registration technique can be used to determine the dosimetric effect of a given plan in the presence of non-rigid tissue motion. In addition to dose accumulation, we describe a method for estimating the biological effects of tissue motion using a linear-quadratic model. This work is described in the context of a prostate treatment protocol, but it is of general applicability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Horn, R. A., & Johnson, C. R. (1985) · Cited by 22,203
Measures of the Amount of Ecologic Association Between Species
Dice, L. R. (1945) · Ecology · doi:10.2307/1932409 · Cited by 11,874
Hapeman, D. E. (1991) · Technometrics · doi:10.1080/00401706.1991.10484817 · Cited by 9,373
Principal warps: thin-plate splines and the decomposition of deformations
Bookstein, F. L. (1989) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.24792 · Cited by 4,913
Fleiss, J. L., & Agresti, A. (1991) · Journal of the American Statistical Association · doi:10.2307/2290537 · Cited by 2,641
Image matching as a diffusion process: an analogy with maxwell’s demons
Thirion, J.-P. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(98)80022-4 · Cited by 2,445 · cited 2×
“Wang et al (2005) register CT volumes using a method similar to the demons algorithm of Thirion (1998) .”
MethodThe linear-quadratic formula and progress in fractionated radiotherapy
Fowler, J. F. (1989) · The British Journal of Radiology · doi:10.1259/0007-1285-62-740-679 · Cited by 2,252
Statistical validation of image segmentation quality based on a spatial overlap index1
Zou, K. H., Warfield, S. K., Bharatha, A., Tempany, C. M. C., Kaus, M. R., Haker, S. J., Wells, W. M., Jolesz, F. A., & Kikinis, R. (2004) · Academic Radiology · doi:10.1016/s1076-6332(03)00671-8 · Cited by 1,849
Computing Large Deformation Metric Mappings via Geodesic Flows of Diffeomorphisms
Beg, M. F., Miller, M. I., Trouvé, A., & Younes, L. (2005) · International Journal of Computer Vision · doi:10.1023/b:visi.0000043755.93987.aa · Cited by 1,719
Morphometric analysis of white matter lesions in MR images: method and validation
Zijdenbos, A. P., Dawant, B. M., Margolin, R. A., & Palmer, A. C. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363096 · Cited by 1,265
Cited by
Elastix: a toolbox for intensity-based medical image registration
Klein, S., Staring, M., Murphy, K., Viergever, M. A., & Pluim, J. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2035616 · Cited by 4,311
“ment plans for radiotherapy and surgery [5], [6], atlas-based”
BackgroundMedical image registration: a review
Oliveira, F. P. M., & Tavares, J. M. R. S. (2014) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255842.2012.670855 · Cited by 737
MIND: Modality independent neighbourhood descriptor for multi-modal deformable registration
Heinrich, M. P., Jenkinson, M., Bhushan, M., Matin, T., Gleeson, F. V., Brady, S. M., & Schnabel, J. A. (2012) · Medical Image Analysis · doi:10.1016/j.media.2012.05.008 · Cited by 707
Klein, S., Staring, M., & Pluim, J. P. W. (2007) · IEEE Transactions on Image Processing · doi:10.1109/tip.2007.909412 · Cited by 431
Klein, S., van der Heide, U. A., Lips, I. M., van Vulpen, M., Staring, M., & Pluim, J. P. W. (2008) · Medical Physics · doi:10.1118/1.2842076 · Cited by 414
Results of a Multi-Institution Deformable Registration Accuracy Study (MIDRAS)
Brock, K. K. (2010) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2009.06.031 · Cited by 358
The ANACONDA algorithm for deformable image registration in radiotherapy
Weistrand, O., & Svensson, S. (2015) · Medical Physics · doi:10.1118/1.4894702 · Cited by 284
The need for application‐based adaptation of deformable image registration
Kirby, N., Chuang, C., Ueda, U., & Pouliot, J. (2013) · Medical Physics · doi:10.1118/1.4769114 · Cited by 164
Metadata
- Authors
- Foskey, M., Davis, B., Goyal, L., Chang, S., Chaney, E., Strehl, N., Tomei, S., Rosenman, J., & Joshi, S.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2005-12-06
- Volume
- 50
- Issue
- 24
- Pages
- 5869-5892
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2159971808
- Cited by
- 172
- References
- 32
- FWCI
- 14.73
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.