The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Evaluation of Optimization Methods for Nonrigid Medical Image Registration Using Mutual Information and B-Splines
Abstract
A popular technique for nonrigid registration of medical images is based on the maximization of their mutual information, in combination with a deformation field parameterized by cubic B-splines. The coordinate mapping that relates the two images is found using an iterative optimization procedure. This work compares the performance of eight optimization methods: gradient descent (with two different step size selection algorithms), quasi-Newton, nonlinear conjugate gradient, Kiefer-Wolfowitz, simultaneous perturbation, Robbins-Monro, and evolution strategy. Special attention is paid to computation time reduction by using fewer voxels to calculate the cost function and its derivatives. The optimization methods are tested on manually deformed CT images of the heart, on follow-up CT chest scans, and on MR scans of the prostate acquired using a BFFE, T1, and T2 protocol. Registration accuracy is assessed by computing the overlap of segmented edges. Precision and convergence properties are studied by comparing deformation fields. The results show that the Robbins-Monro method is the best choice in most applications. With this approach, the computation time per iteration can be lowered approximately 500 times without affecting the rate of convergence by using a small subset of the image, randomly selected in every iteration, to compute the derivative of the mutual information. From the other methods the quasi-Newton and the nonlinear conjugate gradient method achieve a slightly higher precision, at the price of larger computation times.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Stochastic Approximation Method
Robbins, H., & Monro, S. (1951) · The Annals of Mathematical Statistics · doi:10.1214/aoms/1177729586 · Cited by 9,643
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547
Completely Derandomized Self-Adaptation in Evolution Strategies
Hansen, N., & Ostermeier, A. (2001) · Evolutionary Computation · doi:10.1162/106365601750190398 · Cited by 4,397
Multivariate stochastic approximation using a simultaneous perturbation gradient approximation
Spall, J. C. (1992) · IEEE Transactions on Automatic Control · doi:10.1109/9.119632 · Cited by 2,283
Cited by
Elastix: a toolbox for intensity-based medical image registration
Klein, S., Staring, M., Murphy, K., Viergever, M. A., & Pluim, J. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2035616 · Cited by 4,311
Self-citationDeformable medical image registration: a survey
Sotiras, A., Davatzikos, C., & Paragios, N. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2265603 · Cited by 1,587
“[400] studied two variants of gradient descent.”
MethodInfluentialViolet, J., Jackson, P., Ferdinandus, J., Sandhu, S., Akhurst, T., Iravani, A., Kong, G., Kumar, A. R., Thang, S. P., Eu, P., et al. (2019) · Journal of Nuclear Medicine · doi:10.2967/jnumed.118.219352 · Cited by 504
Isgum, I., Staring, M., Rutten, A., Prokop, M., Viergever, M. A., & van Ginneken, B. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.2011480 · Cited by 361
Self-citationWhite matter lesion extension to automatic brain tissue segmentation on MRI
de Boer, R., Vrooman, H. A., van der Lijn, F., Vernooij, M. W., Ikram, M. A., van der Lugt, A., Breteler, M. M. B., & Niessen, W. J. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.01.011 · Cited by 329
Metadata
- Authors
- Klein, S., Staring, M., & Pluim, J. P. W.
- Venue
- IEEE Transactions on Image Processing
- Published
- 2007-12
- Volume
- 16
- Issue
- 12
- Pages
- 2879-2890
- ISSN
- 1057-7149 (ISSN-L)
- OpenAlex
- W2167090712
- Cited by
- 431
- References
- 5
- FWCI
- 31.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of Optimization Methods for Nonrigid Medical Image Registration Using Mutual Information and B-Splines. https://app.cochat.ai/papers/10.1109/tip.2007.909412
- The paper
- Klein, S., Staring, M., & Pluim, J. P. W. (2007). Evaluation of Optimization Methods for Nonrigid Medical Image Registration Using Mutual Information and B-Splines. IEEE Transactions on Image Processing. https://doi.org/10.1109/tip.2007.909412
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).